Tunable White LED Sheet 480x240mm | 24V | 2700-6500K | 576 LEDs | #6600 is manufactured by DENO LED, a Shenzhen-based LED lighting manufacturer with its own Foshan production base. Key data: 2835 LEDs, 576 LEDs/pcs, 24V, 240x480mm FPCB, 2oz copper foil, 20~120W power, cut unit 2LEDs/20*20mm. Built on 99.9% pure copper FPCB with 99.99% gold bonding wire and covered by a 5-year warranty, it is specified for architectural, retail, hospitality and joinery lighting. OEM and ODM builds of length, colour temperature, CRI and ingress protection are available.

Description

This 24V tunable white LED sheet features 576 SMD 2835 LEDs across a 480x240mm flexible PCB, delivering smooth CCT tuning from 2700K to 6500K. Engineered for high efficacy reaching up to 234.8 lm/W, this dimmable panel maintains tight color consistency with single-bin sub-3 SDCM LED binning. Featuring a cuttable 2-LED grid every 20x20mm with heavy 2oz copper foil, the sheet easily trims to fit complex, irregular lightbox shapes. Optimized for architectural backlighting of translucent stone like onyx and marble, the wide 120-degree beam angle eliminates dark spots behind thin panels. Available in multiple CRI grades up to full spectrum, we provide factory-direct wholesale project supply with custom configurations for commercial lighting contractors.

Specifications

SDCM< 3 SDCM (Single Bin)
LED QTY576 LEDs/pcs
PART NODL-F28A576V24-6600-*
SMD TYPE2835
CUTTABLE UNIT2LEDs/20*20mm
DIMMABLEYes
LED PITCH20mm
PCB WIDTH240x480mm
WARRANTY5 Years
BEAM ANGLE120°
RUN LENGTH4pcs
COPPER FOIL2oz
POWER RANGE20~120W
CIRCUIT TYPEC.V.
INPUT VOLTAGE24V
OPERATING TEMPERATURE-25~40°C;Tc:75°C(max)

Applications

  • Backlit stone, onyx & marble surfaces — 480×240mm modules tile behind translucent slabs to deliver even backlighting without hotspots across large countertop and wall panels.
  • Shallow lightboxes & SEG frames — Sheet format keeps the illuminated cavity thin, so signage and fabric lightboxes stay slim while staying evenly lit edge to edge.
  • Curved and irregular panels — The flexible sheet can be free-cut and shaped to follow non-rectangular graphics, reception desks and column cladding.
  • Trade-show & retail backlit graphics — A single 24V feed lights a large backlit graphic, simplifying wiring for shopfitting and trade-show installs.
  • Hotel & residential tunable-white scenes — Hotel rooms, residential living areas and meeting spaces where warm evening light and neutral daytime light are both required from one fixture.

Request a quotation for #6600

DENO LED is a Shenzhen-based LED strip manufacturer with its own Foshan production base. Send the run length, voltage, CCT/CRI and IP rating you need and our engineering team replies with a specification sheet, wiring plan and price — OEM/ODM and fully custom builds included.

  • Warranty: 5 years
  • Lead time: standard boards: samples from 1 working day · custom: 3–5 working days · new FPCB: 1–3 weeks · production 1–2 weeks after sample approval
  • Compliance: CE · UL · RoHS
  • Bonding wire: 99.99% pure gold
  • Copper foil: 99.9% pure copper FPCB

Contact DENO LED engineers · OEM / ODM capability

Photometric Performance — CCT × CRI Efficacy Matrix

Peak measured luminous efficacy: 234.8 lm/W at 6500K, Ra 80, ErP energy class A (Grade DN (1st Tier) · CCT 3-Anchor · 20W/m).

All values are measured at the stated power density and ambient 25 °C, reported as luminous efficacy in lumens per watt (lm/W), luminous flux per metre (lm/m) and the corresponding EU ErP (2019/2015) energy class.

Grade DN (1st Tier) · CCT 3-Anchor · 20W/m

Grade DN (1st Tier) · CCT 3-Anchor · 20W/m — measured at 20 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
2700 K211.6 lm/W2115.9 lm/mB171.2 lm/W1712.4 lm/mD133.6 lm/W1336.5 lm/mE
4000 K213.8 lm/W4275.2 lm/mB173 lm/W3460.3 lm/mC135 lm/W2700.5 lm/mE
6500 K234.8 lm/W2348.2 lm/mA190.3 lm/W1903.4 lm/mC148.4 lm/W1484.1 lm/mD

Grade DN (1st Tier) · CCT 3-Anchor · 30W/m

Grade DN (1st Tier) · CCT 3-Anchor · 30W/m — measured at 30 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
2700 K197.2 lm/W2958.6 lm/mC159.6 lm/W2394.4 lm/mD124.6 lm/W1868.7 lm/mE
4000 K199.3 lm/W5977.7 lm/mC161.3 lm/W4838.3 lm/mD125.9 lm/W3776 lm/mE
6500 K218.9 lm/W3283.3 lm/mB177.4 lm/W2661.4 lm/mC138.3 lm/W2075.1 lm/mE

Grade DN (1st Tier) · CCT 3-Anchor · 60W/m

Grade DN (1st Tier) · CCT 3-Anchor · 60W/m — measured at 60 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
2700 K159.8 lm/W4792.8 lm/mD129.3 lm/W3878.8 lm/mE100.9 lm/W3027.3 lm/mF
4000 K161.4 lm/W9683.7 lm/mD130.6 lm/W7838 lm/mE101.9 lm/W6117 lm/mF
6500 K177.3 lm/W5318.9 lm/mC143.7 lm/W4311.3 lm/mE112.1 lm/W3361.7 lm/mF

Grade DN (1st Tier) · CCT 3-Anchor · 80W/m

Grade DN (1st Tier) · CCT 3-Anchor · 80W/m — measured at 80 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
2700 K138.8 lm/W5552.8 lm/mE112.3 lm/W4493.9 lm/mF87.7 lm/W3507.3 lm/mG
4000 K140.2 lm/W11219.3 lm/mE113.5 lm/W9080.8 lm/mF88.6 lm/W7087 lm/mG
6500 K154.1 lm/W6162.4 lm/mD124.9 lm/W4995 lm/mE97.4 lm/W3894.7 lm/mF

Grade DN (1st Tier) · CCT 3-Anchor · 120W/m

Grade DN (1st Tier) · CCT 3-Anchor · 120W/m — measured at 120 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
2700 K104.8 lm/W6288.9 lm/mF84.8 lm/W5089.6 lm/mG66.2 lm/W3972.3 lm/mG
4000 K105.9 lm/W12706.6 lm/mF85.7 lm/W10284.6 lm/mG66.9 lm/W8026.4 lm/mG
6500 K116.3 lm/W6979.3 lm/mF94.3 lm/W5657.1 lm/mF73.5 lm/W4411 lm/mG

Grade DL (2nd Tier) · CCT 3-Anchor · 20W/m

Grade DL (2nd Tier) · CCT 3-Anchor · 20W/m — measured at 20 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
2700 K168.9 lm/W1688.8 lm/mC136.2 lm/W1362.1 lm/mD106.3 lm/W1062.9 lm/mF
4000 K170.5 lm/W3409.1 lm/mC137.6 lm/W2751.7 lm/mD107.3 lm/W2145.5 lm/mF
6500 K187.4 lm/W1873.8 lm/mB151.4 lm/W1513.6 lm/mD118.1 lm/W1181 lm/mE

Grade DL (2nd Tier) · CCT 3-Anchor · 30W/m

Grade DL (2nd Tier) · CCT 3-Anchor · 30W/m — measured at 30 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
2700 K157.4 lm/W2361.4 lm/mD127 lm/W1904.5 lm/mE99.1 lm/W1486.2 lm/mF
4000 K158.9 lm/W4766.8 lm/mD128.3 lm/W3847.5 lm/mE100 lm/W2999.9 lm/mF
6500 K174.7 lm/W2620.1 lm/mC141.1 lm/W2116.4 lm/mD110.1 lm/W1651.3 lm/mE

Grade DL (2nd Tier) · CCT 3-Anchor · 60W/m

Grade DL (2nd Tier) · CCT 3-Anchor · 60W/m — measured at 60 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
2700 K127.5 lm/W3825.3 lm/mE102.8 lm/W3085.2 lm/mF80.3 lm/W2407.6 lm/mG
4000 K128.7 lm/W7722 lm/mE103.9 lm/W6232.9 lm/mF81 lm/W4859.7 lm/mG
6500 K141.5 lm/W4244.4 lm/mD114.3 lm/W3428.5 lm/mE89.2 lm/W2675.1 lm/mF

Grade DL (2nd Tier) · CCT 3-Anchor · 80W/m

Grade DL (2nd Tier) · CCT 3-Anchor · 80W/m — measured at 80 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
2700 K110.8 lm/W4431.9 lm/mE89.4 lm/W3574.5 lm/mF69.7 lm/W2789.3 lm/mG
4000 K111.8 lm/W8946.5 lm/mE90.3 lm/W7221.3 lm/mF70.4 lm/W5630.3 lm/mG
6500 K122.9 lm/W4917.5 lm/mE99.3 lm/W3972.2 lm/mF77.5 lm/W3099.3 lm/mG

Grade DL (2nd Tier) · CCT 3-Anchor · 120W/m

Grade DL (2nd Tier) · CCT 3-Anchor · 120W/m — measured at 120 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
2700 K83.7 lm/W5019.4 lm/mG67.5 lm/W4048.3 lm/mG52.7 lm/W3159.1 lm/mG
4000 K84.4 lm/W10132.5 lm/mG68.2 lm/W8178.5 lm/mG53.1 lm/W6376.7 lm/mG
6500 K92.8 lm/W5569.4 lm/mF75 lm/W4498.8 lm/mG58.5 lm/W3510.1 lm/mG

Grade KE (3rd Tier) · CCT 3-Anchor · 20W/m

Grade KE (3rd Tier) · CCT 3-Anchor · 20W/m — measured at 20 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
2700 K121.2 lm/W1212.5 lm/mE97.2 lm/W972.3 lm/mF75.8 lm/W757.8 lm/mG
4000 K122.6 lm/W2452.5 lm/mE98.2 lm/W1964.4 lm/mF76.6 lm/W1531.3 lm/mG
6500 K134.4 lm/W1344.4 lm/mE108.1 lm/W1080.6 lm/mF84.2 lm/W842.4 lm/mG

Grade KE (3rd Tier) · CCT 3-Anchor · 30W/m

Grade KE (3rd Tier) · CCT 3-Anchor · 30W/m — measured at 30 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
2700 K113 lm/W1695.3 lm/mE90.6 lm/W1359.6 lm/mF70.6 lm/W1059.6 lm/mG
4000 K114.3 lm/W3429.2 lm/mE91.6 lm/W2746.7 lm/mF71.4 lm/W2141.2 lm/mG
6500 K125.3 lm/W1879.7 lm/mE100.7 lm/W1510.9 lm/mF78.5 lm/W1177.9 lm/mG

Grade KE (3rd Tier) · CCT 3-Anchor · 60W/m

Grade KE (3rd Tier) · CCT 3-Anchor · 60W/m — measured at 60 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
2700 K91.5 lm/W2746.4 lm/mF73.4 lm/W2202.5 lm/mG57.2 lm/W1716.5 lm/mG
4000 K92.6 lm/W5555.2 lm/mF74.2 lm/W4449.5 lm/mG57.8 lm/W3468.7 lm/mG
6500 K101.5 lm/W3045.1 lm/mF81.6 lm/W2447.7 lm/mG63.6 lm/W1908.2 lm/mG

Grade KE (3rd Tier) · CCT 3-Anchor · 80W/m

Grade KE (3rd Tier) · CCT 3-Anchor · 80W/m — measured at 80 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
2700 K79.5 lm/W3181.9 lm/mG63.8 lm/W2551.7 lm/mG49.7 lm/W1988.7 lm/mG
4000 K80.5 lm/W6436.1 lm/mG64.4 lm/W5155.1 lm/mG50.2 lm/W4018.7 lm/mG
6500 K88.2 lm/W3528 lm/mF70.9 lm/W2835.8 lm/mG55.3 lm/W2210.8 lm/mG

Grade KE (3rd Tier) · CCT 3-Anchor · 120W/m

Grade KE (3rd Tier) · CCT 3-Anchor · 120W/m — measured at 120 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
2700 K60.1 lm/W3603.7 lm/mG48.2 lm/W2890 lm/mG37.5 lm/W2252.3 lm/mG
4000 K60.7 lm/W7289.3 lm/mG48.7 lm/W5838.5 lm/mG37.9 lm/W4551.4 lm/mG
6500 K66.6 lm/W3995.7 lm/mG53.5 lm/W3211.7 lm/mG41.7 lm/W2503.9 lm/mG

Related models in this series

See every model in Flexible LED Sheets or narrow to Single Color Led Sheet. Compare wattage, lumen output and run length in the ProCalc parameter library, or request OEM/ODM pricing on the custom manufacturing page.

Frequently Asked Questions

What are the key specifications of #6600?

Tunable White LED Sheet 480x240mm | 24V | 2700-6500K | 576 LEDs | #6600: 2835 LEDs, 576 LEDs/pcs, 24V, 240x480mm FPCB, 2oz copper foil, 20~120W power, cut unit 2LEDs/20*20mm. Photometric files, wiring diagrams and test reports are available in the downloads block on this page.

Which LED driver and run length suit #6600?

Tunable White LED Sheet 480x240mm | 24V | 2700-6500K | 576 LEDs | #6600 is a constant-voltage 24V product, so pair it with a CE or UL listed 24V constant-voltage LED driver rated about 20% above the connected load. Maximum single run is 4pcs. 4pcs Single / 8pcs Dual Input power. Feeding from both ends or mid-feeding halves the copper distance and roughly quarters the voltage drop.

Where can #6600 be cut on site?

Cut only on the printed cut marks: 2LEDs/20*20mm. LED pitch is 20mm. Re-solder the cut end or use a matched solderless connector, and reseal the end cap on IP-rated versions so the ingress rating is kept.

How is #6600 mounted in a lightbox or behind backlit stone?

The 480 x 240 mm sheet is a flat panel, not a strip, so it is not installed in an aluminium channel. Fix it flat to the lightbox back panel or to the substrate behind the translucent slab using the thermal adhesive backing or mechanical fixings, tiling several sheets edge to edge for larger surfaces. Mount it against a metal or aluminium-faced back panel so the panel spreads the heat, since there is no channel acting as a heat sink. Uniformity is set by the cavity depth between the sheet and the diffuser together with the LED pitch of the model, not by the wattage alone - see the tested lightbox depth and cutting comparison on this page.

How bright is #6600 and how wide is the beam?

Beam angle is 120°. Mounting depth, diffuser transmittance and LED pitch decide the final uniformity, so plan the lightbox cavity depth together with the LED pitch rather than the wattage alone.

Engineering & selection guide

Bending limits, IP selection, voltage drop, cutting and the full buyer Q&A for this family are kept on the series page.

Tested lightbox depth, cutting precision and efficacy — all 10 LED sheets compared

Three numbers decide whether an LED sheet works in your cabinet: the diffuser depth it needs before the dots disappear, the smallest piece you can cut without losing a channel, and the load it puts on the driver. The table below lists all ten DENO FlexLite sheets against those three measured figures so a shallow stone lightbox, an irregular logo or a low-load SEG frame can be specified in one pass.

LED sheet comparison: tested minimum diffuser depth, smallest cuttable unit and power range / efficacy for each 480 × 240 mm FlexLite sheet.
ModelFamily / gridLED pitchTested lightbox depthCutting precisionLoad / efficacy
#6433Single colour — 288 × 283520 mm15–25 mm1 LED — 20 × 20 mm, both axes20–138 W per sheet
#6600 (this page)Tunable white 2700–6500 K — 576 × 283520 mm15–25 mm2 LEDs — 20 × 20 mm, both axes20–120 W per sheet · 234.8 lm/W peak
#6352RGB — 288 × 505020 mm15–25 mm12 LEDs — every 20 mm, one axis17.2–70 W per sheet
#17947RGB — 162 × 505026.7 mm30 mm and deeper6 LEDs — every 53.3 mm, one axisLower current than #6352 at the same voltage
#16797RGBW — 288 × 505019.9 mm15–25 mm12 LEDs — every 120 mm, one axisHighest RGBW density in the range
#16796RGBW — 162 × 505026.7 mm30 mm and deeper6 LEDs — 53.3 × 80 mm, both axes13–50 W per sheet
#16795RGBW — 98 × 505034.3 mm30–40 mm7 LEDs — 34.3 × 240 mm, one axis12–26.8 W per sheet — lowest load of the bare-emitter grids
#6432RGBWW 5-in-1 — 288 × 505020 mm20–40 mm12 LEDs — 20 × 240 mm, one axis20–110 W per sheet
#6105Wide-angle lens, 24 V — 50 × 2835, 160° lens48 mm40–60 mm1 LED — 48 × 48 mm, both axes12–60 W per sheet — 50 LEDs cover the full sheet
#6710Wide-angle lens, 12 V — 50 × 6060, 160° lens48 mm40–60 mm1 LED — 48 × 48 mm, both axes10–60 W per sheet at 12 V
  • Diffuser depth is the air gap measured between the LED sheet and opal acrylic in our lightbox rig; a translucent stone slab counts its own thickness towards that gap.
  • Cutting precision is the smallest complete unit that keeps every colour channel intact — always cut on the printed line so the reconnection pads survive.
  • Plan four sheets from a single-end feed and eight with dual-end input, then size the driver at the sheet's maximum wattage plus 30 % headroom.