DENO LED Lighting

LED Strip Engineering Selection Handbook

Compare SOB, roll-to-roll, high-density, wall washer and ultra-long LED strip selection criteria and engineering parameters.

01 / SOB · Continuous optical line

SOB uses individually packaged, gold-wire-bonded LEDs soldered to a flexible circuit under a continuous silicone optical layer. This differs from bare-die COB under a shared phosphor layer.

Selection matrix

Project conditionSelection directionCheck before specifying
Shallow profile, visible light lineSOB with a matched diffuserProfile depth, viewing angle and dot visibility on a sample
Colour-critical displaySOB with the required colour-rendering optionModel-specific CRI, binning and CCT
Extended continuous installationSOB-R2R or constant-current SOB where offeredContinuous circuit length, feed layout and powered-run limit

Parameter comparison

ParameterOptions or constructionEngineering decision
Emitter architectureSOB: packaged LEDs / COB: bare diesSelect by package construction, not visual similarity alone
Optical surfaceContinuous silicone layer / model-specific diffuserConfirm appearance in the actual mounting profile
Electrical designVoltage and current method vary by modelRead the product sheet before sizing feeds and drivers

Packaging type alone does not establish an IP rating, run length, lifetime or performance guarantee.

View products

02 / R2R · Continuous circuit

DENO produces SMD-R2R and SOB-R2R strips on continuously electroplated flexible circuits. R2R describes the circuit manufacturing process; it is not a promise that one feed can power an entire reel.

Selection matrix

Project conditionSelection directionCheck before specifying
Few accessible splice locationsContinuous R2R circuitSpecified unspliced circuit length and cut points
Long run with uniform appearanceR2R circuit with a suitable feed or constant-current designVoltage drop, actual load and far-end output
SOB optical line plus continuous circuitSOB-R2R variantBoth packaging and circuit construction on the selected model

Parameter comparison

ParameterOptions or constructionEngineering decision
Circuit fabricationContinuous electroplated web / joined die-cut panelsCheck intermediate splice count within the ordered length
Copper construction35 µm base + 70 µm electroplated = 105 µm on specified buildsConfirm the copper build of the actual model
Run planningCircuit length / powered run / supplied reel lengthTreat these as three separate specifications

Continuous circuit length, powered-run length and reel length are different values. Do not infer one from another.

View products

03 / High density · Pitch and diffusion

High-density strips reduce the spacing between packaged LEDs. Visible dotting depends on LED pitch, diffuser depth, diffuser transmittance and beam angle together.

Selection matrix

Project conditionSelection directionCheck before specifying
Close-viewed joineryShorter-pitch model with a matched diffuserMock-up at the intended viewing distance
Shallow aluminium channelCompare high-density SMD with a continuous-line optionChannel depth, diffuser type and installed appearance
Colour-sensitive displayHigh-density model with specified rendering and binningProduct-specific CRI, CCT and binning

Parameter comparison

ParameterOptions or constructionEngineering decision
LED pitchShorter / longer spacingCompare the actual LED/m and pitch of candidate models
Profile depthShallow / deeper cavityCheck overlap at the actual diffuser distance
DiffuserHigher / lower transmittanceBalance dot control against delivered light

LED density alone never guarantees a dot-free installation; test the specified profile and diffuser together.

View products

04 / Wall washer · Beam and setback

Flexible wall washers use secondary optics to direct light across an architectural surface. Grazing and washing require different beam shapes and mounting geometry.

Selection matrix

Project conditionSelection directionCheck before specifying
Reveal surface textureNarrow-beam grazing arrangementSetback, aiming, surface finish and mock-up
Evenly light a wallWider or asymmetric washing arrangementBeam angle, setback and illumination uniformity
Outdoor or wet locationModel and sealing selected for the exposureExact model IP rating, end seals and site water exposure

Parameter comparison

ParameterOptions or constructionEngineering decision
Optical taskGrazing / washingChoose texture emphasis or even vertical illumination first
Lens15° / 30° / 60° options on applicable modelsConfirm model availability and photometry before specifying
Ingress exposureIP65 water jets / IP67 temporary immersionOne rating does not automatically establish the other

Beam uniformity depends on lens, mounting distance and surface. IP ratings are model- and installation-specific.

View products

05 / Ultra-long · Power distribution

Long-run strip selection separates circuit construction from power distribution. Per-segment linear constant-current designs can help regulate output within their specified electrical limits.

Selection matrix

Project conditionSelection directionCheck before specifying
Feed available at one endCheck a model rated for the required single-end runW/m, voltage drop and far-end brightness
Feeds available at both endsCompare both-end feeding with single-end feedingDriver capacity and effective feed distance
Concealed middle accessMid-strip tap where permitted by the modelSegment wiring, polarity and actual installation layout

Parameter comparison

ParameterOptions or constructionEngineering decision
Control methodConstant voltage / per-segment constant currentConfirm driver and strip compatibility
Feed positionSingle end / both ends / mid-strip tapBoth-end or central feed can reduce farthest feed distance to L/2
Supply24 V / 36 V / 48 V on applicable modelsVerify selected model, load and driver before sizing the run

No universal maximum powered length: determine it for the selected model, voltage, load and feed topology.

View products