Overview

15mm | 24V | 160LEDs | 50mm/cut | #4944 | 2835 High Light Efficacy Multi-Line LED Strip Light is part of the DENO High Light Efficacy SMD Strips series, engineered around high efficacy LED strip lights. Key specifications: 2835, 160 LEDs/m, 24V, 15mm PCB, 3oz copper FPCB, cuttable 8LEDs/50mm. Every reel is produced on DENO's roll-to-roll line with 99.9% pure copper FPCB and ships CE, UL and RoHS compliant for architectural, retail and hospitality projects. OEM and ODM configurations of length, colour temperature and waterproofing are available on request.

Description

15mm | 24V | 160LEDs | 50mm/cut | #4944 | 2835 High Light Efficacy Multi-Line LED Strip Light Strong pure copper LED frame, and diameter>1mm, 99.9%-purity gold wire encapsulation, can reduce damage to the LED in different applications.

We use 99.99% gold wire, large-size chips, and thickened FPCB, backed by a 5-year warranty.

Specifications

LED QTY160 LEDs/m
PART NODL-F28A80V24-4944-*
SMD TYPE2835
CUTTABLE UNIT8LEDs/50mm
DIMMABLEYes
LED PITCH12.5mm
PCB WIDTH15mm
BEAM ANGLE120°
LENGTH MAX5m
COPPER FOIL3oz
POWER RANGE4.8~28.8W
CIRCUIT TYPEC.V.
INPUT VOLTAGE24V

Applications

  • Cove, wall-wash & perimeter lighting — Coves, recesses, wall-wash details and ceiling perimeters where a continuous, uniform line of light is required.
  • Showroom & hospitality display lighting — Shelving, display cases, reception desks and signage backlighting in shops, showrooms and hospitality spaces.
  • Kitchen & wardrobe under-cabinet lighting — Kitchen, wardrobe and furniture task lighting where the strip stays hidden and only the light is seen.

Request a quotation for #4944

DENO LED is a Shenzhen-based LED strip manufacturer with its own Foshan production base. Send the run length, voltage, CCT/CRI and IP rating you need and our engineering team replies with a specification sheet, wiring plan and price — OEM/ODM and fully custom builds included.

  • Warranty: 5 years
  • Compliance: CE · UL · RoHS
  • Bonding wire: 99.99% pure gold
  • Copper foil: 99.9% pure copper FPCB

Contact DENO LED engineers · OEM / ODM capability

Photometric Performance — CCT × CRI Efficacy Matrix

Peak measured luminous efficacy: 207.2 lm/W at 4000K, Ra 80, ErP energy class B (Grade DN (1st Tier)).

All values are measured at the stated power density and ambient 25 °C, reported as luminous efficacy in lumens per watt (lm/W), luminous flux per metre (lm/m) and the corresponding EU ErP (2019/2015) energy class.

Grade DN (1st Tier)

Grade DN (1st Tier) — measured at 9.6 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K162.4 lm/W1559.1 lm/mD137 lm/W1314.9 lm/mE
2300 K177.1 lm/W1699.8 lm/mC152.8 lm/W1467.3 lm/mD123.8 lm/W1188.5 lm/mE
2700 K190.8 lm/W1831.6 lm/mC165.5 lm/W1588.4 lm/mD134.1 lm/W1287.5 lm/mE
3000 K200.4 lm/W1923.5 lm/mB174.6 lm/W1676.3 lm/mC142 lm/W1362.7 lm/mE
3500 K203.4 lm/W1952.8 lm/mB178.4 lm/W1712.5 lm/mC146.8 lm/W1409.6 lm/mD
4000 K207.2 lm/W1988.9 lm/mB179.4 lm/W1722.2 lm/mC148.1 lm/W1421.3 lm/mD
5000 K206.9 lm/W1986 lm/mB180.5 lm/W1733 lm/mC148.9 lm/W1429.4 lm/mD
6500 K198.3 lm/W1903.9 lm/mC172.5 lm/W1655.8 lm/mD143.2 lm/W1374.7 lm/mE

Grade DN (1st Tier)

Grade DN (1st Tier) — measured at 12 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K159.7 lm/W1916.3 lm/mD134.7 lm/W1616.1 lm/mE
2300 K174.1 lm/W2089.2 lm/mC150.3 lm/W1803.4 lm/mD121.7 lm/W1460.4 lm/mE
2700 K187.6 lm/W2251.3 lm/mC162.7 lm/W1952.3 lm/mD131.9 lm/W1582.5 lm/mE
3000 K197 lm/W2364.1 lm/mC171.7 lm/W2060.4 lm/mD139.6 lm/W1674.9 lm/mE
3500 K200 lm/W2400.1 lm/mB175.4 lm/W2104.8 lm/mC144.4 lm/W1732.6 lm/mE
4000 K203.7 lm/W2444.6 lm/mB176.4 lm/W2116.8 lm/mC145.6 lm/W1747 lm/mE
5000 K203.4 lm/W2441 lm/mB177.5 lm/W2130 lm/mC146.4 lm/W1756.8 lm/mD
6500 K195 lm/W2340.1 lm/mC169.6 lm/W2035.1 lm/mD140.8 lm/W1689.6 lm/mE

Grade DN (1st Tier)

Grade DN (1st Tier) — measured at 15 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K156.4 lm/W2345.4 lm/mD131.9 lm/W1978 lm/mE
2300 K170.5 lm/W2557 lm/mD147.2 lm/W2207.3 lm/mD119.2 lm/W1788 lm/mE
2700 K183.7 lm/W2755.4 lm/mC159.3 lm/W2389.5 lm/mD129.1 lm/W1936.9 lm/mE
3000 K192.9 lm/W2893.5 lm/mC168.1 lm/W2521.7 lm/mD136.7 lm/W2050 lm/mE
3500 K195.8 lm/W2937.6 lm/mC171.7 lm/W2576.1 lm/mD141.4 lm/W2120.6 lm/mE
4000 K199.5 lm/W2992 lm/mC172.7 lm/W2590.8 lm/mD142.5 lm/W2138.2 lm/mE
5000 K199.2 lm/W2987.6 lm/mC173.8 lm/W2607 lm/mC143.4 lm/W2151 lm/mE
6500 K190.9 lm/W2864.1 lm/mC166.1 lm/W2490.9 lm/mD137.8 lm/W2067 lm/mE

Grade DN (1st Tier)

Grade DN (1st Tier) — measured at 28 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K142.7 lm/W3996 lm/mE120.4 lm/W3370 lm/mE
2300 K155.6 lm/W4356.5 lm/mD134.3 lm/W3760.6 lm/mE108.8 lm/W3046.4 lm/mF
2700 K167.7 lm/W4694.5 lm/mD145.4 lm/W4071.1 lm/mE117.9 lm/W3299.9 lm/mF
3000 K176.1 lm/W4929.9 lm/mC153.4 lm/W4296.4 lm/mD124.7 lm/W3492.7 lm/mE
3500 K178.7 lm/W5005 lm/mC156.8 lm/W4389.1 lm/mD129 lm/W3612.9 lm/mE
4000 K182.1 lm/W5097.6 lm/mC157.6 lm/W4414.1 lm/mD130.1 lm/W3642.9 lm/mE
5000 K181.8 lm/W5090.1 lm/mC158.6 lm/W4441.6 lm/mD130.9 lm/W3665.2 lm/mE
6500 K174.3 lm/W4879.8 lm/mC151.6 lm/W4243.8 lm/mD125.8 lm/W3522.4 lm/mE

Grade KE (3rd Tier)

Grade KE (3rd Tier) — measured at 9.6 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K136.1 lm/W1306.5 lm/mD109.2 lm/W1048.1 lm/mF
2300 K151.7 lm/W1456.2 lm/mD121.7 lm/W1168.5 lm/mE98.6 lm/W946.6 lm/mF
2700 K163.5 lm/W1569.8 lm/mC132.1 lm/W1268.3 lm/mE107 lm/W1027.6 lm/mF
3000 K171.8 lm/W1649 lm/mC139.5 lm/W1338.8 lm/mD113.5 lm/W1089.2 lm/mE
3500 K174.3 lm/W1673.5 lm/mC142.2 lm/W1365.2 lm/mD117 lm/W1123.5 lm/mE
4000 K179.4 lm/W1722.4 lm/mC145.3 lm/W1394.6 lm/mD119.9 lm/W1150.9 lm/mE
5000 K179.2 lm/W1720.5 lm/mC145.3 lm/W1394.6 lm/mD119.8 lm/W1150.1 lm/mE
6500 K171.8 lm/W1649 lm/mC139.5 lm/W1338.8 lm/mD115.8 lm/W1111.7 lm/mE

Grade KE (3rd Tier)

Grade KE (3rd Tier) — measured at 12 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K133.8 lm/W1605.8 lm/mE107.4 lm/W1288.3 lm/mF
2300 K149.2 lm/W1789.9 lm/mD119.7 lm/W1436.2 lm/mE96.9 lm/W1162.8 lm/mF
2700 K160.8 lm/W1929.4 lm/mC129.9 lm/W1558.9 lm/mE105.3 lm/W1263 lm/mF
3000 K168.9 lm/W2026.8 lm/mC137.1 lm/W1645.5 lm/mD111.6 lm/W1338.8 lm/mE
3500 K171.4 lm/W2056.9 lm/mC139.8 lm/W1678 lm/mD115.1 lm/W1380.9 lm/mE
4000 K176.4 lm/W2117.1 lm/mC142.8 lm/W1714.1 lm/mD117.9 lm/W1414.6 lm/mE
5000 K176.2 lm/W2114.6 lm/mC142.8 lm/W1714.1 lm/mD117.8 lm/W1413.6 lm/mE
6500 K168.9 lm/W2026.8 lm/mC137.1 lm/W1645.5 lm/mD113.8 lm/W1365.6 lm/mE

Grade KE (3rd Tier)

Grade KE (3rd Tier) — measured at 15 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K131 lm/W1965.4 lm/mE105.1 lm/W1576.8 lm/mF
2300 K146 lm/W2190.7 lm/mD117.2 lm/W1757.8 lm/mE94.9 lm/W1423.5 lm/mF
2700 K157.4 lm/W2361.5 lm/mD127.2 lm/W1908 lm/mE103.1 lm/W1545.8 lm/mF
3000 K165.4 lm/W2480.7 lm/mC134.3 lm/W2014 lm/mE109.2 lm/W1638.6 lm/mF
3500 K167.8 lm/W2517.5 lm/mC136.9 lm/W2053.8 lm/mD112.7 lm/W1690.1 lm/mE
4000 K172.7 lm/W2591.1 lm/mC139.9 lm/W2097.9 lm/mD115.4 lm/W1731.3 lm/mE
5000 K172.5 lm/W2588.2 lm/mC139.9 lm/W2097.9 lm/mD115.4 lm/W1731 lm/mE
6500 K165.4 lm/W2480.7 lm/mC134.3 lm/W2014 lm/mE111.4 lm/W1671 lm/mE

Grade KE (3rd Tier)

Grade KE (3rd Tier) — measured at 28 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K119.6 lm/W3348.6 lm/mE95.9 lm/W2686.4 lm/mF
2300 K133.3 lm/W3732.4 lm/mE107 lm/W2994.9 lm/mF86.6 lm/W2424.8 lm/mF
2700 K143.7 lm/W4023.3 lm/mD116.1 lm/W3250.8 lm/mE94.1 lm/W2633.7 lm/mF
3000 K150.9 lm/W4226.5 lm/mD122.5 lm/W3431.4 lm/mE99.7 lm/W2791.8 lm/mF
3500 K153.2 lm/W4289.2 lm/mD125 lm/W3499.1 lm/mE102.8 lm/W2879.6 lm/mF
4000 K157.7 lm/W4414.6 lm/mD127.7 lm/W3574.4 lm/mE105.3 lm/W2949.8 lm/mF
5000 K157.5 lm/W4409.6 lm/mD127.7 lm/W3574.4 lm/mE105.3 lm/W2948.4 lm/mF
6500 K150.9 lm/W4226.5 lm/mD122.5 lm/W3431.4 lm/mE101.7 lm/W2847.6 lm/mF

Grade DL (2nd Tier)

Grade DL (2nd Tier) — measured at 9.6 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K157.1 lm/W1508.5 lm/mD126.3 lm/W1212.3 lm/mE
2300 K175 lm/W1679.6 lm/mC140.6 lm/W1350.1 lm/mD113.9 lm/W1093.4 lm/mE
2700 K185.3 lm/W1779.3 lm/mB152.1 lm/W1460.6 lm/mD123.3 lm/W1183.9 lm/mE
3000 K197 lm/W1890.7 lm/mB160.2 lm/W1537.8 lm/mC130.2 lm/W1250.4 lm/mE
3500 K199.9 lm/W1919.1 lm/mB163 lm/W1565.2 lm/mC134.1 lm/W1287.5 lm/mE
4000 K206.3 lm/W1980.7 lm/mB166.9 lm/W1602.3 lm/mC137.8 lm/W1322.7 lm/mD
5000 K206 lm/W1977.7 lm/mB166.8 lm/W1601.4 lm/mC137.6 lm/W1321 lm/mD
6500 K189 lm/W1814.5 lm/mB160.1 lm/W1536.8 lm/mC132.9 lm/W1275.8 lm/mE

Grade DL (2nd Tier)

Grade DL (2nd Tier) — measured at 12 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K154.5 lm/W1854.1 lm/mD124.2 lm/W1490 lm/mE
2300 K172 lm/W2064.4 lm/mC138.3 lm/W1659.4 lm/mD112 lm/W1344 lm/mE
2700 K182.2 lm/W2186.9 lm/mC149.6 lm/W1795.2 lm/mD121.3 lm/W1455.1 lm/mE
3000 K193.7 lm/W2323.9 lm/mB157.5 lm/W1890.1 lm/mD128.1 lm/W1536.8 lm/mE
3500 K196.6 lm/W2358.7 lm/mB160.3 lm/W1923.8 lm/mC131.9 lm/W1582.5 lm/mE
4000 K202.9 lm/W2434.4 lm/mB164.1 lm/W1969.4 lm/mC135.5 lm/W1625.8 lm/mD
5000 K202.6 lm/W2430.8 lm/mB164 lm/W1968.2 lm/mC135.3 lm/W1623.6 lm/mD
6500 K185.8 lm/W2230.2 lm/mB157.4 lm/W1888.9 lm/mD130.7 lm/W1568.4 lm/mE

Grade DL (2nd Tier)

Grade DL (2nd Tier) — measured at 15 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K151.3 lm/W2269.3 lm/mD121.6 lm/W1823.6 lm/mE
2300 K168.4 lm/W2526.6 lm/mC135.4 lm/W2031 lm/mD109.7 lm/W1645.5 lm/mF
2700 K178.4 lm/W2676.6 lm/mC146.5 lm/W2197.2 lm/mD118.7 lm/W1781 lm/mE
3000 K189.6 lm/W2844.3 lm/mB154.2 lm/W2313.4 lm/mD125.4 lm/W1881 lm/mE
3500 K192.5 lm/W2886.9 lm/mB157 lm/W2354.6 lm/mD129.1 lm/W1936.9 lm/mE
4000 K198.6 lm/W2979.6 lm/mB160.7 lm/W2410.4 lm/mC132.7 lm/W1989.8 lm/mE
5000 K198.3 lm/W2975.2 lm/mB160.6 lm/W2409 lm/mC132.5 lm/W1987.5 lm/mE
6500 K182 lm/W2729.6 lm/mC154.1 lm/W2311.9 lm/mD127.9 lm/W1918.5 lm/mE

Grade DL (2nd Tier)

Grade DL (2nd Tier) — measured at 28 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K138.1 lm/W3866.3 lm/mD111 lm/W3107 lm/mE
2300 K153.7 lm/W4304.8 lm/mD123.6 lm/W3460.3 lm/mE100.1 lm/W2802.8 lm/mF
2700 K162.9 lm/W4560.3 lm/mC133.7 lm/W3743.5 lm/mE108.4 lm/W3034.4 lm/mF
3000 K173.1 lm/W4846 lm/mC140.8 lm/W3941.4 lm/mD114.5 lm/W3204.8 lm/mE
3500 K175.7 lm/W4918.7 lm/mC143.3 lm/W4011.6 lm/mD117.9 lm/W3300 lm/mE
4000 K181.3 lm/W5076.5 lm/mC146.7 lm/W4106.8 lm/mD121.1 lm/W3390.2 lm/mE
5000 K181 lm/W5069 lm/mC146.6 lm/W4104.3 lm/mD120.9 lm/W3385.2 lm/mE
6500 K166.1 lm/W4650.5 lm/mC140.7 lm/W3938.9 lm/mD116.8 lm/W3270.4 lm/mE

Related models in this series

See every model in SMD LED Strip Series or narrow to Wide. Compare wattage, lumen output and run length in the ProCalc parameter library, or request OEM/ODM pricing on the custom manufacturing page.

Frequently Asked Questions

What are the key specifications of 4944?

4944: 2835, 160 LEDs/m, 24V, 15mm PCB, 3oz copper FPCB, cuttable 8LEDs/50mm. Full photometric data, wiring diagrams and test reports are available in the downloads section of this page.

Which environments is this high efficacy LED strip lights rated for?

Ingress protection for this model is listed in the datasheet. As a high efficacy LED strip lights it is specified for the duty listed in the datasheet, and DENO can supply alternative coatings, sleeves or IP68 potting for harsher installations.

Can DENO customise this high efficacy LED strip lights for a project?

Yes. DENO manufactures the High Light Efficacy SMD Strips series as an OEM and ODM supplier: reel length, colour temperature, CRI grade, PCB width, waterproofing and private labelling can all be specified. Request a quote for lead time and project pricing.

How much can a high efficacy LED strip cut energy use?

Moving from a typical 100 lm/W strip to a 180 to 200 lm/W high lumen LED strip roughly halves the wattage needed for the same lumen output. Over a long commercial run this also lowers the required driver size and helps the installation reach a better ErP energy class.

Which LED driver and run length suit #4944?

15mm | 24V | 160LEDs | 50mm/cut | #4944 | 2835 High Light Efficacy Multi-Line LED Strip Light is a constant-voltage 24V product, so pair it with a CE or UL listed 24V constant-voltage LED driver rated about 20% above the connected load. Maximum single run is 5m. 5m Single / 10m Dual Input power. Feeding from both ends or mid-feeding halves the copper distance and roughly quarters the voltage drop.

High Efficiency LED Strip — Buyer Questions

What counts as a high efficiency LED strip in lumens per watt?

In 2026 a mainstream 24V 2835 board sits around 120-140 lm/W. A high efficiency LED strip starts at roughly 160 lm/W and DENO's top binned 2835 and 2110 boards are measured at up to 200 lm/W at 4000K Ra 80, LM-79 tested at 25 degrees Celsius. The figure is light-source efficacy of the tape itself, measured without the driver, which is exactly how the ErP energy label is calculated.

What is the difference between high efficiency and high efficacy LED strip lights?

They describe the same measurement. Efficacy is the engineering term for lumens delivered per watt consumed; efficiency is how buyers and tender documents usually phrase it. DENO publishes lm/W per model so both audiences read the same number, and the ErP energy class printed on the reel is derived from it.

Which ErP energy class can a high efficiency LED strip reach?

Class C is achievable on the best-binned 2835 and 2110 boards above 180 lm/W, class D covers the 160-180 lm/W band and most well-specified architectural tape lands in class E. High-CRI 95+ and full spectrum builds drop one or two classes because phosphor conversion costs lumens. Every DENO datasheet states the measured class so it can be reproduced by a notified body.

Does a high efficiency LED strip run cooler and last longer?

Yes. Fewer watts per lumen means less heat into the FPCB, so junction temperature drops and L70 lifetime extends. Combined with 2 oz copper and a 99.9% pure copper foil the same brightness can be produced at 20-30% lower wattage, which also lets a single driver feed a longer run and keeps aluminium profiles below the touch-temperature limits used in hospitality projects.

How much energy does a high efficiency LED strip save on a large project?

Take 500 m of cove lighting at 10 hours a day. A 130 lm/W board delivering 1000 lm/m draws about 7.7 W/m; a 190 lm/W board delivers the same output at about 5.3 W/m. Across 500 m that is 1.2 kW saved, roughly 4,380 kWh a year, and it usually removes one driver and one circuit from the electrical schedule as well.

Can I get a high efficiency LED strip in 12V, 24V, 36V or 48V?

24V is the efficiency sweet spot and carries the full binned range. 12V is available where fixture space or existing drivers dictate it, at the cost of shorter single-feed runs. 36V and 48V constant-current boards keep the same lm/W while extending a single feed well past 20 m, which is where the real system efficiency gain shows up on long architectural lines.

Wide PCB LED Strip — Brightest, High Lumen Builds

Why is a wide PCB LED strip the brightest LED strip option?

Brightness is limited by how many dies fit per metre and how much heat the board can shed. A wide PCB LED strip — 18 mm, 20 mm, 36 mm or 64 mm instead of the usual 8–10 mm — carries two, three or four parallel LED rows, up to 960 LEDs/m, and roughly the same multiple of copper area. That is why DENO's widest boards are the brightest LED strip builds in the catalogue: more emitters and enough 2 oz copper to keep junction temperature down at full drive.

Are there super bright LED strip lights in 12V, and when should I use 24V or 48V instead?

12V super bright LED strip lights exist but are limited to short runs: at 20 W/m a 12V board pulls 1.7 A per metre, so voltage drop dims the far end after 2–3 m. For architectural work DENO builds the wide boards in 24V and 48V, where the same wattage draws half or a quarter of the current and one feed covers 5–15 m. Where the fixture is 12V-native, keep the run short and feed each section separately.

Which is brighter — a wide multi-row board or a high-density single row?

For raw output, the wide multi-row board wins: rows multiply the flux while a single row is capped by LED pitch. For a dot-free line in a shallow reveal, high density wins. The two are combined on DENO's 36 mm and 64 mm boards, which run three or four dense rows at once, giving both an ultra bright LED strip face and an even luminance across the diffuser.