DENO LED Lighting

12*12mm Glare-free Neon Lights 128LEDs/m (#10419-GF)

8mm · 24V · 128LEDs · 62.5mm/cut

Model: 10419-GF

10419-GF 8mm | 24V | 128LEDs | 62.5mm/cut | #10419-GF | 12*12mm Glare-free Neon Lights 128LEDs/m — 24V, cuttable every 62.5mm, 8mm FPCB width, 2835 LEDs, 128 LEDs/m

Overview

The DENO LED 10419-GF Glare-free Neon Lights offer a flexible, durable solution for commercial and architectural lighting designs. This model features a 12*12mm silicone injection-moulded design, providing soft light that reduces visual fatigue. With a 24V input and 128 LEDs/m, it's dimmable and cuttable every 62.5mm, allowing for precise customization. Ideal for close observation areas or long-term stay scenarios where comfort and aesthetic appeal are critical. DENO LED pr...

Description

8mm | 24V | 128LEDs | 62.5mm/cut | #10419-GF | 12*12mm Glare-free Neon Lights 128LEDs/m 12*12mm silicone injection-moulded design, offering flexibility and durability. Adding micro-prism structures or soft-light coatings to the surface of the lamp tube can disperse the concentrated light beam into multi-angle soft light, reducing the brightness concentration. The light is soft and not glaring, so even prolonged direct viewing won’t cause dizziness or visual fatigue. It’s suitable for close observation or long-term stay scenarios. While eliminating glare, the neon lights still retain their rich colors and flexible shapes, allowing for customization of lines, patterns, etc., balancing aesthetics and practicality.

Specifications

LED QTY128
PART NODL-NF28C64V24-10419-GF-*
SMD TYPE2835
CUTTABLE UNIT8LEDs/62.5mm
DIMMABLEYes
LED PITCH7.8mm
PCB WIDTH8mm
LENGTH MAX5m
COPPER FOIL3oz
POWER RANGE2.8~23W
CIRCUIT TYPEC.V.
INPUT VOLTAGEDC 24V

Photometric Performance — CCT × CRI Efficacy Matrix

Peak measured luminous efficacy: 55.9 lm/W at 4000K, Ra 80, ErP energy class G (Grade DN (1st Tier) · 6W/m).

All values are measured at the stated power density and ambient 25 °C, reported as luminous efficacy in lumens per watt (lm/W), luminous flux per metre (lm/m) and the corresponding EU ErP (2019/2015) energy class.

Grade DL (2nd Tier) · 6W/m

Grade DL (2nd Tier) · 6W/m — measured at 6 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K27.6 lm/W165.9 lm/mG21.2 lm/W127.3 lm/mG
2300 K30.6 lm/W183.9 lm/mG23.6 lm/W141.4 lm/mG19.2 lm/W115.3 lm/mG
2700 K30.2 lm/W181.3 lm/mG25.5 lm/W153 lm/mG20.7 lm/W124.1 lm/mG
3000 K34.4 lm/W206.4 lm/mG26.9 lm/W161.4 lm/mG21.9 lm/W131.2 lm/mG
3500 K35.1 lm/W210.9 lm/mG27.3 lm/W163.9 lm/mG22.5 lm/W135 lm/mG
4000 K36.2 lm/W217.3 lm/mG28 lm/W167.8 lm/mG23.1 lm/W138.9 lm/mG
5000 K36.2 lm/W217.3 lm/mG28 lm/W167.8 lm/mG22.9 lm/W137.5 lm/mG
6500 K32.1 lm/W192.9 lm/mG26.9 lm/W161.4 lm/mG22.2 lm/W133.3 lm/mG

Grade DL (2nd Tier) · 9.6W/m

Grade DL (2nd Tier) · 9.6W/m — measured at 9.6 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K27 lm/W258.8 lm/mG20.7 lm/W198.6 lm/mG
2300 K29.9 lm/W286.9 lm/mG23 lm/W220.7 lm/mG18.7 lm/W179.8 lm/mG
2700 K29.5 lm/W282.9 lm/mG24.9 lm/W238.7 lm/mG20.2 lm/W193.6 lm/mG
3000 K33.5 lm/W322 lm/mG26.2 lm/W251.8 lm/mG21.3 lm/W204.6 lm/mG
3500 K34.3 lm/W329 lm/mG26.6 lm/W255.8 lm/mG21.9 lm/W210.6 lm/mG
4000 K35.3 lm/W339 lm/mG27.3 lm/W261.8 lm/mG22.6 lm/W216.7 lm/mG
5000 K35.3 lm/W339 lm/mG27.3 lm/W261.8 lm/mG22.3 lm/W214.5 lm/mG
6500 K31.3 lm/W300.9 lm/mG26.2 lm/W251.8 lm/mG21.7 lm/W208 lm/mG

Grade DL (2nd Tier) · 20W/m

Grade DL (2nd Tier) · 20W/m — measured at 20 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K25.1 lm/W501.1 lm/mG19.2 lm/W384.6 lm/mG
2300 K27.8 lm/W555.5 lm/mG21.4 lm/W427.3 lm/mG17.4 lm/W348.2 lm/mG
2700 K27.4 lm/W547.8 lm/mG23.1 lm/W462.3 lm/mG18.7 lm/W374.9 lm/mG
3000 K31.2 lm/W623.5 lm/mG24.4 lm/W487.5 lm/mG19.8 lm/W396.2 lm/mG
3500 K31.9 lm/W637.1 lm/mG24.8 lm/W495.3 lm/mG20.4 lm/W407.9 lm/mG
4000 K32.8 lm/W656.5 lm/mG25.3 lm/W507 lm/mG21 lm/W419.6 lm/mG
5000 K32.8 lm/W656.5 lm/mG25.3 lm/W507 lm/mG20.8 lm/W415.4 lm/mG
6500 K29.1 lm/W582.7 lm/mG24.4 lm/W487.5 lm/mG20.1 lm/W402.8 lm/mG

Grade DN (1st Tier) · 6W/m

Grade DN (1st Tier) · 6W/m — measured at 6 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K43.8 lm/W263 lm/mG36.1 lm/W216.7 lm/mG
2300 K47.8 lm/W286.8 lm/mG40.3 lm/W241.7 lm/mG32.6 lm/W195.3 lm/mG
2700 K51.5 lm/W309.3 lm/mG43.5 lm/W261 lm/mG35.3 lm/W211.5 lm/mG
3000 K54.1 lm/W324.7 lm/mG46.2 lm/W277.1 lm/mG37.6 lm/W225.7 lm/mG
3500 K54.9 lm/W329.2 lm/mG47.3 lm/W283.5 lm/mG38.9 lm/W233.4 lm/mG
4000 K55.9 lm/W335.6 lm/mG47.5 lm/W284.8 lm/mG39.2 lm/W235.3 lm/mG
5000 K55.8 lm/W335 lm/mG47.8 lm/W286.8 lm/mG38.8 lm/W233 lm/mG
6500 K53.6 lm/W321.5 lm/mG45.6 lm/W273.9 lm/mG37.7 lm/W225.9 lm/mG

Grade DN (1st Tier) · 9.6W/m

Grade DN (1st Tier) · 9.6W/m — measured at 9.6 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K42.7 lm/W410.2 lm/mG35.2 lm/W338 lm/mG
2300 K46.6 lm/W447.3 lm/mG39.3 lm/W377.1 lm/mG31.7 lm/W304.7 lm/mG
2700 K50.3 lm/W482.5 lm/mG42.4 lm/W407.2 lm/mG34.4 lm/W330 lm/mG
3000 K52.8 lm/W506.5 lm/mG45 lm/W432.3 lm/mG36.7 lm/W352.1 lm/mG
3500 K53.5 lm/W513.5 lm/mG46.1 lm/W442.3 lm/mG37.9 lm/W364.1 lm/mG
4000 K54.5 lm/W523.6 lm/mG46.3 lm/W444.3 lm/mG38.2 lm/W367.1 lm/mG
5000 K54.4 lm/W522.6 lm/mG46.6 lm/W447.3 lm/mG37.9 lm/W363.4 lm/mG
6500 K52.2 lm/W501.5 lm/mG44.5 lm/W427.3 lm/mG36.7 lm/W352.4 lm/mG

Grade DN (1st Tier) · 20W/m

Grade DN (1st Tier) · 20W/m — measured at 20 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K39.7 lm/W794.4 lm/mG32.7 lm/W654.6 lm/mG
2300 K43.3 lm/W866.3 lm/mG36.5 lm/W730.3 lm/mG29.5 lm/W590.1 lm/mG
2700 K46.7 lm/W934.3 lm/mG39.4 lm/W788.6 lm/mG32 lm/W639 lm/mG
3000 K49 lm/W980.9 lm/mG41.9 lm/W837.2 lm/mG34.1 lm/W681.8 lm/mG
3500 K49.7 lm/W994.5 lm/mG42.8 lm/W856.6 lm/mG35.3 lm/W705.1 lm/mG
4000 K50.7 lm/W1013.9 lm/mG43 lm/W860.5 lm/mG35.5 lm/W710.9 lm/mG
5000 K50.6 lm/W1012 lm/mG43.3 lm/W866.3 lm/mG35.2 lm/W703.8 lm/mG
6500 K48.6 lm/W971.2 lm/mG41.4 lm/W827.5 lm/mG34.1 lm/W682.5 lm/mG

Grade KE (3rd Tier) · 6W/m

Grade KE (3rd Tier) · 6W/m — measured at 6 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K6.5 lm/W39.2 lm/mG4.1 lm/W24.4 lm/mG
2300 K7.3 lm/W43.7 lm/mG4.6 lm/W27.6 lm/mG3.9 lm/W23.5 lm/mG
2700 K7.8 lm/W46.9 lm/mG4.9 lm/W29.6 lm/mG4 lm/W23.8 lm/mG
3000 K8.3 lm/W49.5 lm/mG5.5 lm/W32.8 lm/mG4.4 lm/W26.4 lm/mG
3500 K8.4 lm/W50.1 lm/mG5.6 lm/W33.4 lm/mG4.6 lm/W27.6 lm/mG
4000 K8.6 lm/W51.4 lm/mG5.8 lm/W34.7 lm/mG4.7 lm/W28.3 lm/mG
5000 K8.6 lm/W51.4 lm/mG5.8 lm/W34.7 lm/mG4.7 lm/W28 lm/mG
6500 K8.3 lm/W49.5 lm/mG5.5 lm/W32.8 lm/mG4.5 lm/W27.2 lm/mG

Grade KE (3rd Tier) · 9.6W/m

Grade KE (3rd Tier) · 9.6W/m — measured at 9.6 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K6.4 lm/W61.2 lm/mG4 lm/W38.1 lm/mG
2300 K7.1 lm/W68.2 lm/mG4.5 lm/W43.1 lm/mG3.8 lm/W36.6 lm/mG
2700 K7.6 lm/W73.2 lm/mG4.8 lm/W46.1 lm/mG3.9 lm/W37.1 lm/mG
3000 K8 lm/W77.2 lm/mG5.3 lm/W51.2 lm/mG4.3 lm/W41.1 lm/mG
3500 K8.1 lm/W78.2 lm/mG5.4 lm/W52.2 lm/mG4.5 lm/W43.1 lm/mG
4000 K8.4 lm/W80.2 lm/mG5.6 lm/W54.2 lm/mG4.6 lm/W44.1 lm/mG
5000 K8.4 lm/W80.2 lm/mG5.6 lm/W54.2 lm/mG4.6 lm/W43.7 lm/mG
6500 K8 lm/W77.2 lm/mG5.3 lm/W51.2 lm/mG4.4 lm/W42.4 lm/mG

Grade KE (3rd Tier) · 20W/m

Grade KE (3rd Tier) · 20W/m — measured at 20 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K5.9 lm/W118.5 lm/mG3.7 lm/W73.8 lm/mG
2300 K6.6 lm/W132.1 lm/mG4.2 lm/W83.5 lm/mG3.5 lm/W70.9 lm/mG
2700 K7.1 lm/W141.8 lm/mG4.5 lm/W89.4 lm/mG3.6 lm/W71.9 lm/mG
3000 K7.5 lm/W149.6 lm/mG5 lm/W99.1 lm/mG4 lm/W79.6 lm/mG
3500 K7.6 lm/W151.5 lm/mG5.1 lm/W101 lm/mG4.2 lm/W83.5 lm/mG
4000 K7.8 lm/W155.4 lm/mG5.2 lm/W104.9 lm/mG4.3 lm/W85.5 lm/mG
5000 K7.8 lm/W155.4 lm/mG5.2 lm/W104.9 lm/mG4.2 lm/W84.6 lm/mG
6500 K7.5 lm/W149.6 lm/mG5 lm/W99.1 lm/mG4.1 lm/W82 lm/mG

How Top bending LED neon flex 10419-GF performs on site

Specification notes for 12x12mm section 24V DC silicone neon: what it does outdoors, what it does around water, and how far it bends when you trace a building.

Outdoor & façade exposure

Specify for permanent exterior installation above the waterline (IP67).

The silicone is injection moulded onto the FPCB in one shot, so there is no glued cover to open up after a winter of thermal cycling — the failure mode PVC neon rope light shows in its second outdoor summer. UV-stabilised silicone keeps its colour instead of yellowing, and the body stays elastic from −30 °C to +80 °C, so a façade run installed in summer will not go brittle in a January frost. Feed with 24V DC and plan 5m per feed to hold end-of-run brightness across a long elevation.

  • Sealed silicone body
  • UV-stable silicone, −30 °C to +80 °C
  • 2.8W/m load

Pools, spas & wet areas

Suitable for pool surrounds, spa ceilings and steam-adjacent joinery — not for submersion.

IP67 covers rain, splash, wash-down and steam — pool decks, shower reveals, sauna ceilings and spa coves — but the body is not intended to sit under water. Mount it above the waterline in an aluminium groove so condensate drains away from the feed joint, run 24V DC for wet-zone safety, and choose the IP68 variant where the channel can flood.

  • IP67 — splash and rain, not submersion
  • 24V DC
  • Moulded end cap and feed joint

Architectural contour & signage

Bends vertically, over and under the emitting face at about R36mm — the right pick for channel letters, logos, arches, domes and cove crests.

Top bending LED neon flex takes its curve vertically, over and under the emitting face, which is what decides whether a shape is possible without cutting and re-soldering. At about R36mm the outside of the curve stays evenly lit: 128 LEDs/m is matched to the diffuser depth so you read a continuous line of light rather than dots, even at 30 cm. Printed cut marks with indexed solder pads underneath let a sign maker shorten a letter stroke on site and re-seal it, and mounting clips, aluminium grooves and moulded bend grooves cover surface, recessed and free-form fixing.

  • Cross-section 12x12mm
  • Bend radius about R36mm
  • 128 LEDs/m, dot-free

Frequently Asked Questions

What are the key benefits of using glare-free neon lights in commercial applications?

Glare-free neon lights enhance visual comfort, reducing eye strain for occupants. This improves productivity and customer experience in retail, offices, and hospitality settings. They offer aesthetic flexibility while being functional.

Is the DENO LED 10419-GF compatible with standard 24V constant voltage drivers?

Yes, the 10419-GF model is designed for a DC 24V input and operates as a constant voltage circuit type, making it compatible with most standard 24V CV LED power supplies and dimmers.

Can these glare-free neon lights be customized for specific project lengths or shapes?

Absolutely. The 10419-GF is flexible and has a cuttable increment of 62.5mm (8 LEDs), allowing for precise length adjustments and intricate shape formations to meet diverse project requirements. Contact us for custom solutions.

What certifications do DENO LED products typically hold for B2B reliability?

DENO LED products, including the 10419-GF, commonly hold certifications such as CE, RoHS, and UL, ensuring they meet rigorous safety, quality, and environmental standards for B2B market reliability and compliance.

Top Bending LED Neon Flex — Buyer Questions

What is a top bending LED neon flex?

A top bend neon strip flexes up and down, perpendicular to the emitting face, so it can crest over an edge, follow a dome or climb a vertical stroke while the light window keeps facing the viewer. It is the most common neon body type and covers cove lighting, step nosing, signage letters and handrails.

Which top bend neon size should I specify?

Cross-sections run 5×11 mm, 10×10 mm, 12×12 mm, 16×16 mm, 20×18 mm, 20×20 mm and 25×25 mm. Small sections suit letters and slim reveals; 16×16 mm and above give the deep, saturated neon line specified for façade and feature work. Match the emitting window to the visible aperture of the channel and keep the LED pitch at 120 LEDs/m or denser for a dot-free result.