Is 36V or 48V better for a long LED strip installation?

Use 48V when a single uninterrupted run has to exceed about 30 m, and 36V when the run sits between 20 m and 30 m or when a 48V driver is not available for the project. Both remain within SELV limits, both cut voltage drop compared with 24V — 48V draws half the current of 24V for the same wattage, and loss falls with the square of current — and both come at the cost of a longer cut unit, which is the main practical trade-off.

The trade-off is cut unit, not safety

Higher voltage means more LEDs sit in series inside each repeating segment, so the smallest length you can cut grows: roughly 50 mm at 24V, 100 mm at 36V and up to 166.6 mm at 48V. On a facade or a long corridor that is irrelevant; in joinery where the line has to stop within a few millimetres of a reveal, it decides the design.

Both voltages stay well below the 60 V DC SELV threshold, so neither changes the wiring classification. What does change is driver availability and cost — 48V constant-voltage drivers are common in commercial ranges but less so in residential product lines.

Selecting between them

A quick decision path for long installations:

  • Run under 20 m, tight cut needed — stay at 24V with CC ICs
  • 20–30 m, moderate cut tolerance — 36V, 100 mm cut unit
  • Over 30 m, or one driver for the whole run — 48V, 3 oz copper
  • Any voltage: both-ends or mid-feed halves the electrical distance
  • Confirm the dimming protocol is supported at the chosen driver voltage