DENO LED Lighting

2835 High Light Efficacy High Lumen LED Strip Light (#5381)

10mm · 24V · 64LEDs · 125cut

Model: 5381

5381 10mm | 24V | 64LEDs | 125cut | #5381 | 2835 High Light Efficacy High Lumen LED Strip Light — 24V, cuttable every 125mm, 10mm FPCB width, 2835 LEDs, 64 LEDs/m

Overview

10mm | 24V | 64LEDs | 125cut | #5381 | 2835 High Light Efficacy High Lumen LED Strip Light is part of the DENO High Light Efficacy SMD Strips series, engineered around high efficacy LED strip lights. Key specifications: 2835, 64LED/m, 24V, 10mm PCB, 3oz copper FPCB, cuttable 8LEDs/125mm. Every reel is produced on DENO's roll-to-roll line with 99.9% pure copper FPCB and ships CE, UL and RoHS compliant for architectural, retail and hospitality projects. OEM and ODM configurations of length, colour temperature and waterproofing are available on request.

Description

10mm | 24V | 64LEDs | 125cut | #5381 | 2835 High Light Efficacy High Lumen LED Strip Light Strong pure copper LED frame, and diameter>1mm, 99.9%-purity gold wire encapsulation, can reduce damage to the LED in different applications.

High Efficacy Led Strip Lights built for high light efficacy smd strips projects.

Specifications

LED QTY64LED/m
PART NODL-F28A32V24-5381-*
SMD TYPE2835
CUTTABLE UNIT8LEDs/125mm
DIMMABLEYes
LED PITCH15.6mm
PCB WIDTH10mm
BEAM ANGLE120°
LENGTH MAX5m
COPPER FOIL3oz
POWER RANGE2~12W
CIRCUIT TYPEC.V.
INPUT VOLTAGE24V

Applications

  • Cove, wall-wash & perimeter lighting — Coves, recesses, wall-wash details and ceiling perimeters where a continuous, uniform line of light is required.
  • Showroom & hospitality display lighting — Shelving, display cases, reception desks and signage backlighting in shops, showrooms and hospitality spaces.
  • Kitchen & wardrobe under-cabinet lighting — Kitchen, wardrobe and furniture task lighting where the strip stays hidden and only the light is seen.

Request a quotation for #5381

DENO LED is a Shenzhen-based LED strip manufacturer with its own Foshan production base. Send the run length, voltage, CCT/CRI and IP rating you need and our engineering team replies with a specification sheet, wiring plan and price — OEM/ODM and fully custom builds included.

  • Warranty: 5 years
  • Compliance: CE · UL · RoHS
  • Bonding wire: 99.99% pure gold
  • Copper foil: 99.9% pure copper FPCB

Contact DENO LED engineers · OEM / ODM capability

Photometric Performance — CCT × CRI Efficacy Matrix

Peak measured luminous efficacy: 198.2 lm/W at 4000K, Ra 80, ErP energy class C (Grade DN (1st Tier)).

All values are measured at the stated power density and ambient 25 °C, reported as luminous efficacy in lumens per watt (lm/W), luminous flux per metre (lm/m) and the corresponding EU ErP (2019/2015) energy class.

Grade DL (2nd Tier)

Grade DL (2nd Tier) — measured at 4.8 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K147.8 lm/W709.4 lm/mD118.7 lm/W569.7 lm/mE
2300 K164.6 lm/W790.2 lm/mC132.2 lm/W634.5 lm/mE107.1 lm/W514.1 lm/mF
2700 K174.2 lm/W836.1 lm/mC143.1 lm/W686.7 lm/mD116 lm/W556.6 lm/mE
3000 K185.3 lm/W889.3 lm/mB150.5 lm/W722.5 lm/mD122.4 lm/W587.6 lm/mE
3500 K188 lm/W902.4 lm/mB153.2 lm/W735.5 lm/mD126.1 lm/W605.5 lm/mE
4000 K194 lm/W931.4 lm/mB157 lm/W753.4 lm/mD129.6 lm/W621.9 lm/mE
5000 K193.7 lm/W929.9 lm/mB156.9 lm/W752.9 lm/mD129.4 lm/W621.1 lm/mE
6500 K177.7 lm/W853 lm/mC150.4 lm/W722 lm/mD124.8 lm/W599 lm/mE

Grade DL (2nd Tier)

Grade DL (2nd Tier) — measured at 6 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K146.6 lm/W879.3 lm/mD117.7 lm/W706.1 lm/mE
2300 K163.2 lm/W979.4 lm/mC131.1 lm/W786.4 lm/mE106.2 lm/W637.2 lm/mF
2700 K172.7 lm/W1036.4 lm/mC141.9 lm/W851.2 lm/mD115 lm/W689.9 lm/mE
3000 K183.7 lm/W1102.3 lm/mC149.3 lm/W895.5 lm/mD121.4 lm/W728.3 lm/mE
3500 K186.4 lm/W1118.5 lm/mB152 lm/W911.7 lm/mD125.1 lm/W750.5 lm/mE
4000 K192.4 lm/W1154.5 lm/mB155.6 lm/W933.9 lm/mD128.5 lm/W770.8 lm/mE
5000 K192.1 lm/W1152.7 lm/mB155.5 lm/W933.3 lm/mD128.3 lm/W769.8 lm/mE
6500 K176.2 lm/W1057.4 lm/mC149.2 lm/W894.9 lm/mD123.8 lm/W742.8 lm/mE

Grade DL (2nd Tier)

Grade DL (2nd Tier) — measured at 9.6 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K142.9 lm/W1371.8 lm/mD114.7 lm/W1101.6 lm/mE
2300 K159.2 lm/W1528 lm/mD127.8 lm/W1226.9 lm/mE103.5 lm/W993.6 lm/mF
2700 K168.4 lm/W1616.8 lm/mC138.3 lm/W1327.9 lm/mD112.1 lm/W1076.3 lm/mE
3000 K179.1 lm/W1719.7 lm/mC145.5 lm/W1397.1 lm/mD118.3 lm/W1136.2 lm/mE
3500 K181.8 lm/W1744.9 lm/mC148.2 lm/W1422.3 lm/mD122 lm/W1170.8 lm/mE
4000 K187.6 lm/W1801 lm/mB151.8 lm/W1456.9 lm/mD125.3 lm/W1202.5 lm/mE
5000 K187.3 lm/W1798.2 lm/mB151.7 lm/W1456 lm/mD125.1 lm/W1201 lm/mE
6500 K171.8 lm/W1649.5 lm/mC145.4 lm/W1396.1 lm/mD120.7 lm/W1158.7 lm/mE

Grade DN (1st Tier)

Grade DN (1st Tier) — measured at 4.8 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K155.3 lm/W745.3 lm/mD131 lm/W628.6 lm/mE
2300 K169.3 lm/W812.8 lm/mD146.1 lm/W701.4 lm/mD118.4 lm/W568.3 lm/mF
2700 K182.5 lm/W875.9 lm/mC158.2 lm/W759.3 lm/mD128.3 lm/W615.6 lm/mE
3000 K191.6 lm/W919.8 lm/mC166.9 lm/W801.2 lm/mD135.8 lm/W651.8 lm/mE
3500 K194.5 lm/W933.8 lm/mC170.5 lm/W818.6 lm/mD140.4 lm/W673.9 lm/mE
4000 K198.2 lm/W951.1 lm/mC171.5 lm/W823.4 lm/mD141.6 lm/W679.7 lm/mE
5000 K197.9 lm/W949.7 lm/mC172.6 lm/W828.7 lm/mD142.4 lm/W683.5 lm/mE
6500 K189.7 lm/W910.7 lm/mC165 lm/W792.1 lm/mD137 lm/W657.6 lm/mE

Grade DN (1st Tier)

Grade DN (1st Tier) — measured at 6 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K154 lm/W923.8 lm/mD129.9 lm/W779.2 lm/mE
2300 K167.9 lm/W1007.5 lm/mD144.9 lm/W869.4 lm/mE117.4 lm/W704.4 lm/mF
2700 K181 lm/W1085.7 lm/mC156.9 lm/W941.1 lm/mD127.2 lm/W763.1 lm/mE
3000 K190 lm/W1140.1 lm/mC165.5 lm/W993.1 lm/mD134.6 lm/W807.9 lm/mE
3500 K192.9 lm/W1157.4 lm/mC169.1 lm/W1014.6 lm/mD139.2 lm/W835.4 lm/mE
4000 K196.5 lm/W1179 lm/mC170.1 lm/W1020.6 lm/mD140.4 lm/W842.5 lm/mE
5000 K196.2 lm/W1177.2 lm/mC171.2 lm/W1027.2 lm/mD141.2 lm/W847.2 lm/mE
6500 K188.1 lm/W1128.8 lm/mC163.6 lm/W981.8 lm/mD135.8 lm/W814.8 lm/mE

Grade DN (1st Tier)

Grade DN (1st Tier) — measured at 9.6 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K150.1 lm/W1441.2 lm/mD126.6 lm/W1215.6 lm/mE
2300 K163.7 lm/W1571.7 lm/mD141.3 lm/W1356.3 lm/mE114.4 lm/W1098.2 lm/mF
2700 K176.4 lm/W1693.8 lm/mC152.9 lm/W1468.2 lm/mD124 lm/W1190.4 lm/mE
3000 K185.3 lm/W1778.6 lm/mC161.4 lm/W1549.3 lm/mD131.3 lm/W1260.3 lm/mE
3500 K188.1 lm/W1805.7 lm/mC164.9 lm/W1582.9 lm/mD135.8 lm/W1303.2 lm/mE
4000 K191.6 lm/W1839.2 lm/mC165.9 lm/W1592.2 lm/mD136.9 lm/W1314.4 lm/mE
5000 K191.3 lm/W1836.4 lm/mC166.9 lm/W1602.4 lm/mD137.7 lm/W1321.9 lm/mE
6500 K183.4 lm/W1760.9 lm/mC159.5 lm/W1531.6 lm/mD132.4 lm/W1271 lm/mE

Grade KE (3rd Tier)

Grade KE (3rd Tier) — measured at 4.8 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K116.8 lm/W560.7 lm/mE93.5 lm/W449 lm/mF
2300 K130.2 lm/W625 lm/mE104.2 lm/W500.3 lm/mF84.4 lm/W405.1 lm/mG
2700 K140.3 lm/W673.3 lm/mD113.2 lm/W543.3 lm/mE91.7 lm/W440.3 lm/mF
3000 K147.4 lm/W707.6 lm/mD119.5 lm/W573.7 lm/mE97.2 lm/W466.4 lm/mF
3500 K149.5 lm/W717.8 lm/mD121.8 lm/W584.9 lm/mE100.3 lm/W481.4 lm/mF
4000 K154 lm/W739 lm/mD124.5 lm/W597.4 lm/mE102.7 lm/W493 lm/mF
5000 K153.8 lm/W738.1 lm/mD124.5 lm/W597.4 lm/mE102.7 lm/W493 lm/mF
6500 K147.3 lm/W707.1 lm/mD119.5 lm/W573.7 lm/mE99.2 lm/W476.2 lm/mF

Grade KE (3rd Tier)

Grade KE (3rd Tier) — measured at 6 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K115.8 lm/W695 lm/mE92.8 lm/W556.6 lm/mF
2300 K129.1 lm/W774.7 lm/mE103.3 lm/W620.1 lm/mF83.7 lm/W502.2 lm/mG
2700 K139.1 lm/W834.6 lm/mD112.2 lm/W673.4 lm/mE91 lm/W545.8 lm/mF
3000 K146.2 lm/W877.1 lm/mD118.5 lm/W711.2 lm/mE96.4 lm/W578.2 lm/mF
3500 K148.3 lm/W889.7 lm/mD120.8 lm/W724.9 lm/mE99.5 lm/W596.7 lm/mF
4000 K152.7 lm/W916.1 lm/mD123.4 lm/W740.5 lm/mE101.9 lm/W611.1 lm/mF
5000 K152.5 lm/W914.9 lm/mD123.4 lm/W740.5 lm/mE101.8 lm/W610.8 lm/mF
6500 K146.1 lm/W876.5 lm/mD118.5 lm/W711.2 lm/mE98.4 lm/W590.4 lm/mF

Grade KE (3rd Tier)

Grade KE (3rd Tier) — measured at 9.6 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K112.9 lm/W1084.2 lm/mE90.4 lm/W868.3 lm/mF
2300 K125.9 lm/W1208.5 lm/mE100.8 lm/W967.4 lm/mF81.6 lm/W783.4 lm/mG
2700 K135.6 lm/W1302 lm/mD109.4 lm/W1050.6 lm/mF88.7 lm/W851.5 lm/mF
3000 K142.5 lm/W1368.3 lm/mD115.6 lm/W1109.4 lm/mE94 lm/W901.9 lm/mF
3500 K144.6 lm/W1388 lm/mD117.8 lm/W1130.9 lm/mE97 lm/W930.9 lm/mF
4000 K148.9 lm/W1429.1 lm/mD120.3 lm/W1155.2 lm/mE99.3 lm/W953.3 lm/mF
5000 K148.7 lm/W1427.2 lm/mD120.3 lm/W1155.2 lm/mE99.3 lm/W953.3 lm/mF
6500 K142.4 lm/W1367.4 lm/mD115.6 lm/W1109.4 lm/mE95.9 lm/W920.6 lm/mF

Related models in this series

See every model in SMD LED Strip Series or narrow to 2835. Compare wattage, lumen output and run length in the ProCalc parameter library, or request OEM/ODM pricing on the custom manufacturing page.

Frequently Asked Questions

What are the key specifications of 5381?

5381: 2835, 64LED/m, 24V, 10mm PCB, 3oz copper FPCB, cuttable 8LEDs/125mm. Full photometric data, wiring diagrams and test reports are available in the downloads section of this page.

Which environments is this high efficacy LED strip lights rated for?

Ingress protection for this model is listed in the datasheet. As a high efficacy LED strip lights it is specified for the duty listed in the datasheet, and DENO can supply alternative coatings, sleeves or IP68 potting for harsher installations.

Can DENO customise this high efficacy LED strip lights for a project?

Yes. DENO manufactures the High Light Efficacy SMD Strips series as an OEM and ODM supplier: reel length, colour temperature, CRI grade, PCB width, waterproofing and private labelling can all be specified. Request a quote for lead time and project pricing.

How much can a high efficacy LED strip cut energy use?

Moving from a typical 100 lm/W strip to a 180 to 200 lm/W high lumen LED strip roughly halves the wattage needed for the same lumen output. Over a long commercial run this also lowers the required driver size and helps the installation reach a better ErP energy class.

Which LED driver and run length suit #5381?

10mm | 24V | 64LEDs | 125cut | #5381 | 2835 High Light Efficacy High Lumen LED Strip Light is a constant-voltage 24V product, so pair it with a CE or UL listed 24V constant-voltage LED driver rated about 20% above the connected load. Maximum single run is 5m. 5m Single/10m Dual Input power. Feeding from both ends or mid-feeding halves the copper distance and roughly quarters the voltage drop.

High Efficiency LED Strip — Buyer Questions

What counts as a high efficiency LED strip in lumens per watt?

In 2026 a mainstream 24V 2835 board sits around 120-140 lm/W. A high efficiency LED strip starts at roughly 160 lm/W and DENO's top binned 2835 and 2110 boards are measured at up to 200 lm/W at 4000K Ra 80, LM-79 tested at 25 degrees Celsius. The figure is light-source efficacy of the tape itself, measured without the driver, which is exactly how the ErP energy label is calculated.

What is the difference between high efficiency and high efficacy LED strip lights?

They describe the same measurement. Efficacy is the engineering term for lumens delivered per watt consumed; efficiency is how buyers and tender documents usually phrase it. DENO publishes lm/W per model so both audiences read the same number, and the ErP energy class printed on the reel is derived from it.

Which ErP energy class can a high efficiency LED strip reach?

Class C is achievable on the best-binned 2835 and 2110 boards above 180 lm/W, class D covers the 160-180 lm/W band and most well-specified architectural tape lands in class E. High-CRI 95+ and full spectrum builds drop one or two classes because phosphor conversion costs lumens. Every DENO datasheet states the measured class so it can be reproduced by a notified body.

Does a high efficiency LED strip run cooler and last longer?

Yes. Fewer watts per lumen means less heat into the FPCB, so junction temperature drops and L70 lifetime extends. Combined with 2 oz copper and a 99.9% pure copper foil the same brightness can be produced at 20-30% lower wattage, which also lets a single driver feed a longer run and keeps aluminium profiles below the touch-temperature limits used in hospitality projects.

How much energy does a high efficiency LED strip save on a large project?

Take 500 m of cove lighting at 10 hours a day. A 130 lm/W board delivering 1000 lm/m draws about 7.7 W/m; a 190 lm/W board delivers the same output at about 5.3 W/m. Across 500 m that is 1.2 kW saved, roughly 4,380 kWh a year, and it usually removes one driver and one circuit from the electrical schedule as well.

Can I get a high efficiency LED strip in 12V, 24V, 36V or 48V?

24V is the efficiency sweet spot and carries the full binned range. 12V is available where fixture space or existing drivers dictate it, at the cost of shorter single-feed runs. 36V and 48V constant-current boards keep the same lm/W while extending a single feed well past 20 m, which is where the real system efficiency gain shows up on long architectural lines.