DENO LED Lighting

2835 High Light Efficacy High Lumen PU LED Strip Light (#3015-PU)

12mm · 24V · 128LEDs · 62.5mm/cut

Model: 3015-PU

3015-PU 12mm | 24V | 128LEDs | 62.5mm/cut | #3015-PU | 2835 High Light Efficacy High Lumen PU LED Strip Light — 24V, cuttable every 62.5mm, 10mm FPCB width, 2835 LEDs, 128 LEDs/m, 1800-6500

Overview

12mm | 24V | 128LEDs | 62.5mm/cut | #3015-PU | 2835 High Light Efficacy High Lumen PU LED Strip Light is part of the DENO Marine Grade SMD Strips series, engineered around marine grade LED strip. Key specifications: 2835, 128, 24V, 10mm PCB, 3 oz copper FPCB, cuttable 8LEDs/62.5mm, IP68PU, CRI Ra≥80 , Ra≥90 , Ra≥95 , FS. Every reel is produced on DENO's roll-to-roll line with 99.9% pure copper FPCB and ships CE, UL and RoHS compliant for architectural, retail and hospitality projects. OEM and ODM configurations of length, colour temperature and waterproofing are available on request.

Description

12mm | 24V | 128LEDs | 62.5mm/cut | #3015-PU | 2835 High Light Efficacy High Lumen PU LED Strip Light High-efficiency LEDs, providing professional linear lighting effect. PU potting High-efficiency LED Strip utilizes polyurethane potting as a waterproofing method, offering excellent waterproof performance. PU material is resistant to UV rays, high and low temperatures, ensuring the strip’s durability. High sealing capability, completely filling gaps to prevent water and dust ingress. Suitable for a wide range of applications including facade lighting, landscape illumination, pathway lighting, and accentuating cultural landmarks.

We use 99.99% gold wire, large-size chips, and thickened FPCB, backed by a 5-year warranty.

Specifications

CCT (K)1800-6500
CRIRa≥80 , Ra≥90 , Ra≥95 , FS
SDCM< 3 SDCM (Single Bin)
LED QTY128
PART NODL-F28D64V24-3015-PU-*
SMD TYPE2835
CUTTABLE UNIT8LEDs/62.5mm
DIMMABLEYes
IP RATINGIP68PU
LED PITCH7.8mm
LIFESPAN50000h
PCB WIDTH10mm
WARRANTY5 Years
BEAM ANGLE120°
LENGTH MAX5m
COPPER FOIL3 oz
ON OFF TIMES10000 (test times)
POWER RANGE2~23W
CIRCUIT TYPEC.V.
INPUT VOLTAGE24V
LUMINOUS FLUX1996 lm/m
MIN BEND DIAMETERΦ60mm
OPERATING TEMPERATURE-25~40°C;Tc: 75°C (max)

Applications

  • Cove, wall-wash & perimeter lighting — Coves, recesses, wall-wash details and ceiling perimeters where a continuous, uniform line of light is required.
  • Showroom & hospitality display lighting — Shelving, display cases, reception desks and signage backlighting in shops, showrooms and hospitality spaces.
  • Kitchen & wardrobe under-cabinet lighting — Kitchen, wardrobe and furniture task lighting where the strip stays hidden and only the light is seen.
  • Facade, landscape & bathroom runs (IP68PU) — IP68PU sealing suits facades, landscape lighting, bathrooms and other locations exposed to rain, splashing or wash-down cleaning.

Request a quotation for #3015-PU

DENO LED is a Shenzhen-based LED strip manufacturer with its own Foshan production base. Send the run length, voltage, CCT/CRI and IP rating you need and our engineering team replies with a specification sheet, wiring plan and price — OEM/ODM and fully custom builds included.

  • Warranty: 5 years
  • Compliance: CE · UL · RoHS
  • Bonding wire: 99.99% pure gold
  • Copper foil: 99.9% pure copper FPCB

Contact DENO LED engineers · OEM / ODM capability

Photometric Performance — CCT × CRI Efficacy Matrix

Peak measured luminous efficacy: 186.1 lm/W at 4000K, Ra 80, ErP energy class B (Grade DL (2nd Tier) · 9.6W/m).

All values are measured at the stated power density and ambient 25 °C, reported as luminous efficacy in lumens per watt (lm/W), luminous flux per metre (lm/m) and the corresponding EU ErP (2019/2015) energy class.

Grade DL (2nd Tier) · 9.6W/m

Grade DL (2nd Tier) · 9.6W/m — measured at 9.6 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K141.8 lm/W1361.4 lm/mD113.8 lm/W1092.1 lm/mE
2300 K157.8 lm/W1515.1 lm/mD126.7 lm/W1216.7 lm/mE102.7 lm/W985.9 lm/mF
2700 K166.8 lm/W1601.5 lm/mC137.1 lm/W1316.2 lm/mD111.1 lm/W1067 lm/mE
3000 K177.7 lm/W1706 lm/mC144.2 lm/W1384.5 lm/mD117.3 lm/W1126.3 lm/mE
3500 K180.3 lm/W1731.1 lm/mC146.8 lm/W1409.6 lm/mD120.9 lm/W1160.4 lm/mE
4000 K186.1 lm/W1786.4 lm/mB150.4 lm/W1443.8 lm/mD124.1 lm/W1191.6 lm/mE
5000 K185.9 lm/W1784.4 lm/mB150.3 lm/W1442.8 lm/mD124 lm/W1190.4 lm/mE
6500 K170.4 lm/W1635.7 lm/mC144.2 lm/W1384.5 lm/mD119.7 lm/W1149.1 lm/mE

Grade DL (2nd Tier) · 11.5W/m

Grade DL (2nd Tier) · 11.5W/m — measured at 11.5 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K139.9 lm/W1609.2 lm/mD112.3 lm/W1290.9 lm/mE
2300 K155.7 lm/W1790.9 lm/mD125.1 lm/W1438.2 lm/mE101.3 lm/W1165 lm/mF
2700 K164.6 lm/W1893 lm/mC135.3 lm/W1555.8 lm/mD109.7 lm/W1261.2 lm/mF
3000 K175.4 lm/W2016.5 lm/mC142.3 lm/W1636.5 lm/mD115.8 lm/W1331.3 lm/mE
3500 K177.9 lm/W2046.2 lm/mC144.9 lm/W1666.2 lm/mD119.3 lm/W1371.7 lm/mE
4000 K183.6 lm/W2111.6 lm/mC148.4 lm/W1706.6 lm/mD122.5 lm/W1408.5 lm/mE
5000 K183.4 lm/W2109.2 lm/mC148.3 lm/W1705.4 lm/mD122.3 lm/W1406.5 lm/mE
6500 K168.1 lm/W1933.4 lm/mC142.3 lm/W1636.5 lm/mD118.1 lm/W1358.2 lm/mE

Grade DL (2nd Tier) · 16W/m

Grade DL (2nd Tier) · 16W/m — measured at 16 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K135.6 lm/W2169.2 lm/mD108.8 lm/W1740.2 lm/mF
2300 K150.9 lm/W2414.2 lm/mD121.2 lm/W1938.7 lm/mE98.1 lm/W1569.6 lm/mF
2700 K159.5 lm/W2551.8 lm/mD131.1 lm/W2097.2 lm/mE106.3 lm/W1700.2 lm/mF
3000 K169.9 lm/W2718.3 lm/mC137.9 lm/W2206 lm/mD112.2 lm/W1794.6 lm/mE
3500 K172.4 lm/W2758.3 lm/mC140.4 lm/W2246.1 lm/mD115.6 lm/W1849 lm/mE
4000 K177.9 lm/W2846.4 lm/mC143.8 lm/W2300.5 lm/mD118.7 lm/W1898.7 lm/mE
5000 K177.7 lm/W2843.2 lm/mC143.7 lm/W2298.9 lm/mD118.5 lm/W1896 lm/mE
6500 K162.9 lm/W2606.3 lm/mC137.9 lm/W2206 lm/mD114.4 lm/W1830.4 lm/mE

Grade DL (2nd Tier) · 19.2W/m

Grade DL (2nd Tier) · 19.2W/m — measured at 19.2 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K132.6 lm/W2545.2 lm/mE106.3 lm/W2041.8 lm/mF
2300 K147.5 lm/W2832.6 lm/mD118.5 lm/W2274.7 lm/mE96 lm/W1843.2 lm/mF
2700 K155.9 lm/W2994.1 lm/mD128.2 lm/W2460.7 lm/mE103.9 lm/W1994.8 lm/mF
3000 K166.1 lm/W3189.5 lm/mC134.8 lm/W2588.4 lm/mE109.7 lm/W2105.7 lm/mF
3500 K168.6 lm/W3236.4 lm/mC137.3 lm/W2635.4 lm/mD113 lm/W2169.5 lm/mE
4000 K173.9 lm/W3339.8 lm/mC140.6 lm/W2699.2 lm/mD116 lm/W2227.8 lm/mE
5000 K173.7 lm/W3336 lm/mC140.5 lm/W2697.4 lm/mD115.9 lm/W2225.3 lm/mE
6500 K159.3 lm/W3058 lm/mD134.8 lm/W2588.4 lm/mE111.9 lm/W2148.5 lm/mE

Grade DN (1st Tier) · 9.6W/m

Grade DN (1st Tier) · 9.6W/m — measured at 9.6 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K135.9 lm/W1305.1 lm/mE114.5 lm/W1099.2 lm/mF
2300 K148.2 lm/W1422.7 lm/mD127.7 lm/W1225.7 lm/mE103.4 lm/W992.6 lm/mF
2700 K159.7 lm/W1533.2 lm/mD138.1 lm/W1326.2 lm/mE112 lm/W1075 lm/mF
3000 K167.8 lm/W1610.5 lm/mD145.9 lm/W1400.6 lm/mD118.7 lm/W1139.3 lm/mF
3500 K170.3 lm/W1634.7 lm/mD149 lm/W1430.7 lm/mD122.7 lm/W1177.5 lm/mE
4000 K173.4 lm/W1664.8 lm/mC149.9 lm/W1438.7 lm/mD123.7 lm/W1187.6 lm/mE
5000 K173.2 lm/W1662.8 lm/mC150.9 lm/W1448.8 lm/mD124.5 lm/W1195.2 lm/mE
6500 K166 lm/W1593.5 lm/mD144.2 lm/W1384.5 lm/mE119.7 lm/W1149.1 lm/mE

Grade DN (1st Tier) · 11.5W/m

Grade DN (1st Tier) · 11.5W/m — measured at 11.5 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K134.1 lm/W1542.7 lm/mE113 lm/W1299.2 lm/mF
2300 K146.2 lm/W1681.6 lm/mD126 lm/W1448.9 lm/mE102.1 lm/W1174.2 lm/mF
2700 K157.6 lm/W1812.3 lm/mD136.3 lm/W1567.6 lm/mE110.5 lm/W1270.7 lm/mF
3000 K165.5 lm/W1903.7 lm/mD144 lm/W1655.5 lm/mE117.1 lm/W1346.7 lm/mF
3500 K168 lm/W1932.2 lm/mD147.1 lm/W1691.1 lm/mD121 lm/W1391.9 lm/mE
4000 K171.1 lm/W1967.9 lm/mD147.9 lm/W1700.6 lm/mD122.1 lm/W1403.7 lm/mE
5000 K170.9 lm/W1965.5 lm/mD148.9 lm/W1712.5 lm/mD122.9 lm/W1413.4 lm/mE
6500 K163.8 lm/W1883.5 lm/mD142.3 lm/W1636.5 lm/mE118.1 lm/W1358.2 lm/mF

Grade DN (1st Tier) · 16W/m

Grade DN (1st Tier) · 16W/m — measured at 16 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K130 lm/W2079.6 lm/mE109.5 lm/W1751.4 lm/mF
2300 K141.7 lm/W2266.9 lm/mE122.1 lm/W1953.1 lm/mE98.9 lm/W1582.4 lm/mF
2700 K152.7 lm/W2443 lm/mD132.1 lm/W2113.2 lm/mE107.1 lm/W1713 lm/mF
3000 K160.4 lm/W2566.2 lm/mD139.5 lm/W2231.7 lm/mE113.5 lm/W1815.4 lm/mF
3500 K162.8 lm/W2604.7 lm/mD142.5 lm/W2279.7 lm/mE117.3 lm/W1876.3 lm/mF
4000 K165.8 lm/W2652.7 lm/mD143.3 lm/W2292.5 lm/mE118.3 lm/W1892.3 lm/mF
5000 K165.6 lm/W2649.5 lm/mD144.3 lm/W2308.5 lm/mE119 lm/W1904 lm/mE
6500 K158.7 lm/W2539 lm/mD137.9 lm/W2206 lm/mE114.4 lm/W1830.4 lm/mF

Grade DN (1st Tier) · 19.2W/m

Grade DN (1st Tier) · 19.2W/m — measured at 19.2 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K127.1 lm/W2440 lm/mE107 lm/W2054.9 lm/mF
2300 K138.5 lm/W2659.8 lm/mE119.4 lm/W2291.6 lm/mE96.7 lm/W1856.6 lm/mF
2700 K149.3 lm/W2866.4 lm/mD129.1 lm/W2479.5 lm/mE104.7 lm/W2009.9 lm/mF
3000 K156.8 lm/W3011 lm/mD136.4 lm/W2618.5 lm/mE110.9 lm/W2130.1 lm/mF
3500 K159.2 lm/W3056.1 lm/mD139.3 lm/W2674.8 lm/mE114.7 lm/W2201.5 lm/mF
4000 K162.1 lm/W3112.5 lm/mD140.1 lm/W2689.8 lm/mE115.6 lm/W2220.2 lm/mF
5000 K161.9 lm/W3108.7 lm/mD141.1 lm/W2708.6 lm/mE116.4 lm/W2234.9 lm/mF
6500 K155.2 lm/W2979.1 lm/mD134.8 lm/W2588.4 lm/mE111.9 lm/W2148.5 lm/mF

Grade KE (3rd Tier) · 9.6W/m

Grade KE (3rd Tier) · 9.6W/m — measured at 9.6 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K140.8 lm/W1351.3 lm/mD112.9 lm/W1084.1 lm/mE
2300 K156.9 lm/W1506.1 lm/mD125.8 lm/W1207.7 lm/mE101.9 lm/W978.2 lm/mF
2700 K169.1 lm/W1623.6 lm/mC136.6 lm/W1311.1 lm/mD110.7 lm/W1063 lm/mE
3000 K177.6 lm/W1705 lm/mC144.2 lm/W1384.5 lm/mD117.3 lm/W1126.3 lm/mE
3500 K180.2 lm/W1730.1 lm/mC147 lm/W1411.6 lm/mD121.1 lm/W1162.4 lm/mE
4000 K185.5 lm/W1780.3 lm/mB150.2 lm/W1441.8 lm/mD124 lm/W1190.6 lm/mE
5000 K185.2 lm/W1778.3 lm/mB150.2 lm/W1441.8 lm/mD123.9 lm/W1189.4 lm/mE
6500 K177.6 lm/W1705 lm/mC144.2 lm/W1384.5 lm/mD119.7 lm/W1149.1 lm/mE

Grade KE (3rd Tier) · 11.5W/m

Grade KE (3rd Tier) · 11.5W/m — measured at 11.5 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K138.9 lm/W1597.3 lm/mD111.4 lm/W1281.4 lm/mE
2300 K154.8 lm/W1780.2 lm/mD124.1 lm/W1427.5 lm/mE100.5 lm/W1155.8 lm/mF
2700 K166.9 lm/W1919.2 lm/mC134.8 lm/W1549.8 lm/mE109.3 lm/W1256.5 lm/mF
3000 K175.2 lm/W2015.4 lm/mC142.3 lm/W1636.5 lm/mD115.8 lm/W1331.3 lm/mE
3500 K177.8 lm/W2045 lm/mC145.1 lm/W1668.6 lm/mD119.5 lm/W1374.1 lm/mE
4000 K183 lm/W2104.4 lm/mC148.2 lm/W1704.2 lm/mD122.4 lm/W1407.3 lm/mE
5000 K182.8 lm/W2102.1 lm/mC148.2 lm/W1704.2 lm/mD122.3 lm/W1406.5 lm/mE
6500 K175.2 lm/W2015.4 lm/mC142.3 lm/W1636.5 lm/mD118.1 lm/W1358.2 lm/mE

Grade KE (3rd Tier) · 16W/m

Grade KE (3rd Tier) · 16W/m — measured at 16 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K134.6 lm/W2153.2 lm/mE108 lm/W1727.4 lm/mF
2300 K150 lm/W2399.7 lm/mD120.3 lm/W1924.3 lm/mE97.4 lm/W1558.4 lm/mF
2700 K161.7 lm/W2587.1 lm/mC130.6 lm/W2089.2 lm/mE105.9 lm/W1693.8 lm/mF
3000 K169.8 lm/W2716.7 lm/mC137.9 lm/W2206 lm/mD112.2 lm/W1794.6 lm/mE
3500 K172.3 lm/W2756.7 lm/mC140.6 lm/W2249.3 lm/mD115.8 lm/W1852.2 lm/mE
4000 K177.3 lm/W2836.8 lm/mC143.6 lm/W2297.3 lm/mD118.6 lm/W1897.1 lm/mE
5000 K177.1 lm/W2833.6 lm/mC143.6 lm/W2297.3 lm/mD118.5 lm/W1896 lm/mE
6500 K169.8 lm/W2716.7 lm/mC137.9 lm/W2206 lm/mD114.4 lm/W1830.4 lm/mE

Grade KE (3rd Tier) · 19.2W/m

Grade KE (3rd Tier) · 19.2W/m — measured at 19.2 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K131.6 lm/W2526.4 lm/mE105.6 lm/W2026.8 lm/mF
2300 K146.7 lm/W2815.7 lm/mD117.6 lm/W2257.8 lm/mE95.3 lm/W1829.8 lm/mF
2700 K158.1 lm/W3035.5 lm/mD127.7 lm/W2451.3 lm/mE103.5 lm/W1987.3 lm/mF
3000 K166 lm/W3187.6 lm/mC134.8 lm/W2588.4 lm/mE109.7 lm/W2105.7 lm/mF
3500 K168.5 lm/W3234.6 lm/mC137.5 lm/W2639.1 lm/mD113.2 lm/W2173.3 lm/mE
4000 K173.4 lm/W3328.5 lm/mC140.4 lm/W2695.5 lm/mD115.9 lm/W2225.9 lm/mE
5000 K173.2 lm/W3324.7 lm/mC140.4 lm/W2695.5 lm/mD115.8 lm/W2223.4 lm/mE
6500 K166 lm/W3187.6 lm/mC134.8 lm/W2588.4 lm/mE111.9 lm/W2148.5 lm/mE

Related models in this series

See every model in SMD LED Strip Series or narrow to 2835. Compare wattage, lumen output and run length in the ProCalc parameter library, or request OEM/ODM pricing on the custom manufacturing page.

Frequently Asked Questions

What are the key specifications of 3015-PU?

3015-PU: 2835, 128, 24V, 10mm PCB, 3 oz copper FPCB, cuttable 8LEDs/62.5mm, IP68PU, CRI Ra≥80 , Ra≥90 , Ra≥95 , FS. Full photometric data, wiring diagrams and test reports are available in the downloads section of this page.

Which environments is this marine grade LED strip rated for?

Ingress protection for this model is IP68PU. As a marine grade LED strip it is specified for the duty listed in the datasheet, and DENO can supply alternative coatings, sleeves or IP68 potting for harsher installations.

Can DENO customise this marine grade LED strip for a project?

Yes. DENO manufactures the Marine Grade SMD Strips series as an OEM and ODM supplier: reel length, colour temperature, CRI grade, PCB width, waterproofing and private labelling can all be specified. Request a quote for lead time and project pricing.

What makes an LED strip marine grade?

Marine LED strip lights need IP67 or IP68 encapsulation, salt-mist resistant coating, tinned copper conductors and UV stable silicone. These boat LED strip lights are built for continuous saltwater spray and vibration rather than the light splash duty a standard waterproof strip is rated for.

How much can a high efficacy LED strip cut energy use?

Moving from a typical 100 lm/W strip to a 180 to 200 lm/W high lumen LED strip roughly halves the wattage needed for the same lumen output. Over a long commercial run this also lowers the required driver size and helps the installation reach a better ErP energy class.

High Efficiency LED Strip — Buyer Questions

What counts as a high efficiency LED strip in lumens per watt?

In 2026 a mainstream 24V 2835 board sits around 120-140 lm/W. A high efficiency LED strip starts at roughly 160 lm/W and DENO's top binned 2835 and 2110 boards are measured at up to 200 lm/W at 4000K Ra 80, LM-79 tested at 25 degrees Celsius. The figure is light-source efficacy of the tape itself, measured without the driver, which is exactly how the ErP energy label is calculated.

What is the difference between high efficiency and high efficacy LED strip lights?

They describe the same measurement. Efficacy is the engineering term for lumens delivered per watt consumed; efficiency is how buyers and tender documents usually phrase it. DENO publishes lm/W per model so both audiences read the same number, and the ErP energy class printed on the reel is derived from it.

Which ErP energy class can a high efficiency LED strip reach?

Class C is achievable on the best-binned 2835 and 2110 boards above 180 lm/W, class D covers the 160-180 lm/W band and most well-specified architectural tape lands in class E. High-CRI 95+ and full spectrum builds drop one or two classes because phosphor conversion costs lumens. Every DENO datasheet states the measured class so it can be reproduced by a notified body.

Does a high efficiency LED strip run cooler and last longer?

Yes. Fewer watts per lumen means less heat into the FPCB, so junction temperature drops and L70 lifetime extends. Combined with 2 oz copper and a 99.9% pure copper foil the same brightness can be produced at 20-30% lower wattage, which also lets a single driver feed a longer run and keeps aluminium profiles below the touch-temperature limits used in hospitality projects.

How much energy does a high efficiency LED strip save on a large project?

Take 500 m of cove lighting at 10 hours a day. A 130 lm/W board delivering 1000 lm/m draws about 7.7 W/m; a 190 lm/W board delivers the same output at about 5.3 W/m. Across 500 m that is 1.2 kW saved, roughly 4,380 kWh a year, and it usually removes one driver and one circuit from the electrical schedule as well.

Can I get a high efficiency LED strip in 12V, 24V, 36V or 48V?

24V is the efficiency sweet spot and carries the full binned range. 12V is available where fixture space or existing drivers dictate it, at the cost of shorter single-feed runs. 36V and 48V constant-current boards keep the same lm/W while extending a single feed well past 20 m, which is where the real system efficiency gain shows up on long architectural lines.