DENO LED Lighting

2835 1-Step (1 SDCM) High Consistency LED Strip 128LEDs/m (#3015-B)

10mm · 24V · 128LEDs · 62.5mm/cut

Model: 3015-B

3015-B 10mm | 24V | 128LEDs | 62.5mm/cut | #3015-B | 2835 1-Step (1 SDCM) High Consistency LED Strip 128LEDs/m — 24V, cuttable every 62.5mm, 10mm FPCB width, 2835 LEDs, 128 LEDs/m

Overview

10mm | 24V | 128LEDs | 62.5mm/cut | #3015-B | 2835 1-Step (1 SDCM) High Consistency LED Strip 128LEDs/m is part of the DENO 1 SDCM SMD Strips series, engineered around 1 SDCM LED strip. Key specifications: 2835, 128, 24V, 10 PCB, 3oz copper FPCB, cuttable 8LEDs/62.5mm. Every reel is produced on DENO's roll-to-roll line with 99.9% pure copper FPCB and ships CE, UL and RoHS compliant for architectural, retail and hospitality projects. OEM and ODM configurations of length, colour temperature and waterproofing are available on request.

Description

10mm | 24V | 128LEDs | 62.5mm/cut | #3015-B | 2835 1-Step (1 SDCM) High Consistency LED Strip 128LEDs/m 1-Step (1 SDCM) binning ensures ultra-tight color tolerance and superior batch-to-batch consistency, delivering uniform light output across the entire strip. High color consistency effectively minimizes visible color deviation or patching, even in applications with fewer LEDs or limited light mixing distance. Constant voltage (C.V.) design ensures stable brightness and consistent performance along the entire strip. High lumen output combined with excellent luminous efficacy delivers both strong brightness and energy efficiency. Supports multiple dimming protocols including PWM, DALI, and 0–10V for versatile lighting control. Ideal for retail lighting, architectural lighting, display showcases, and high-end residential applications.

We use 99.99% gold wire, large-size chips, and thickened FPCB, backed by a 5-year warranty.

Specifications

SDCM< 1 SDCM (Single Bin)
LED QTY128
PART NODL-F28D64V24-3015-B-*
SMD TYPE2835
CUTTABLE UNIT8LEDs/62.5mm
DIMMABLEYes
LED PITCH7.8mm
LIFESPAN50000
PCB WIDTH10
WARRANTY5 Years
BEAM ANGLE120°
LENGTH MAX5m
COPPER FOIL3oz
POWER RANGE2~23W
CIRCUIT TYPEC.V.
INPUT VOLTAGE24V
OPERATING TEMPERATURE-25~40°C;Tc:75°C(max)

Photometric Performance — CCT × CRI Efficacy Matrix

Peak measured luminous efficacy: 154.7 lm/W at 5000K, Ra 90, ErP energy class D (Grade DN (1st Tier) · 4.8W/m).

All values are measured at the stated power density and ambient 25 °C, reported as luminous efficacy in lumens per watt (lm/W), luminous flux per metre (lm/m) and the corresponding EU ErP (2019/2015) energy class.

Grade DL (2nd Tier) · 4.8W/m

Grade DL (2nd Tier) · 4.8W/m — measured at 4.8 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K101.8 lm/W488.7 lm/mF
2300 K113.5 lm/W544.8 lm/mE91.9 lm/W441.1 lm/mF
2700 K122.8 lm/W589.5 lm/mE
3000 K129.2 lm/W620 lm/mE
3500 K131.4 lm/W630.9 lm/mE
4000 K134.6 lm/W646.2 lm/mE
5000 K134.6 lm/W646.2 lm/mE111.1 lm/W533.3 lm/mE
6500 K129.1 lm/W619.5 lm/mE107.1 lm/W514.1 lm/mF

Grade DL (2nd Tier) · 9.6W/m

Grade DL (2nd Tier) · 9.6W/m — measured at 9.6 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K98.4 lm/W945.1 lm/mF
2300 K109.7 lm/W1053.6 lm/mF88.9 lm/W853.4 lm/mF
2700 K118.7 lm/W1140 lm/mE
3000 K124.9 lm/W1199 lm/mE
3500 K127.1 lm/W1220 lm/mE
4000 K130.2 lm/W1249.5 lm/mE
5000 K130.2 lm/W1249.5 lm/mE107.4 lm/W1031 lm/mF
6500 K124.8 lm/W1197.9 lm/mE103.6 lm/W994.6 lm/mF

Grade DL (2nd Tier) · 12W/m

Grade DL (2nd Tier) · 12W/m — measured at 12 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K96.8 lm/W1161.6 lm/mF
2300 K107.9 lm/W1294.9 lm/mF87.4 lm/W1048.8 lm/mF
2700 K116.8 lm/W1401.1 lm/mE
3000 K122.8 lm/W1473.6 lm/mE
3500 K125 lm/W1499.5 lm/mE
4000 K128 lm/W1535.8 lm/mE
5000 K128 lm/W1535.8 lm/mE105.6 lm/W1267.2 lm/mF
6500 K122.7 lm/W1472.4 lm/mE101.8 lm/W1221.6 lm/mF

Grade DL (2nd Tier) · 14.4W/m

Grade DL (2nd Tier) · 14.4W/m — measured at 14.4 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K95.2 lm/W1370.6 lm/mF
2300 K106.1 lm/W1528 lm/mF85.9 lm/W1237 lm/mF
2700 K114.8 lm/W1653.2 lm/mE
3000 K120.8 lm/W1738.8 lm/mE
3500 K122.9 lm/W1769.4 lm/mE
4000 K125.8 lm/W1812.2 lm/mE
5000 K125.8 lm/W1812.2 lm/mE103.8 lm/W1494.7 lm/mF
6500 K120.6 lm/W1737.3 lm/mE100.1 lm/W1441.4 lm/mF

Grade DL (2nd Tier) · 19.2W/m

Grade DL (2nd Tier) · 19.2W/m — measured at 19.2 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K92 lm/W1766.8 lm/mF
2300 K102.6 lm/W1969.7 lm/mF83.1 lm/W1595.5 lm/mG
2700 K111 lm/W2131.2 lm/mE
3000 K116.7 lm/W2241.5 lm/mE
3500 K118.8 lm/W2280.9 lm/mE
4000 K121.7 lm/W2336.1 lm/mE
5000 K121.7 lm/W2336.1 lm/mE100.4 lm/W1927.7 lm/mF
6500 K116.6 lm/W2239.6 lm/mE96.8 lm/W1858.6 lm/mF

Grade DL (2nd Tier) · 22.84W/m

Grade DL (2nd Tier) · 22.84W/m — measured at 22.8 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K89.7 lm/W2049.3 lm/mF
2300 K100 lm/W2283 lm/mF81 lm/W1850 lm/mG
2700 K108.2 lm/W2470.3 lm/mF
3000 K113.8 lm/W2599.6 lm/mE
3500 K115.8 lm/W2646 lm/mE
4000 K118.6 lm/W2709.7 lm/mE
5000 K118.6 lm/W2708.1 lm/mE97.8 lm/W2233.8 lm/mF
6500 K113.7 lm/W2598 lm/mE94.4 lm/W2156.1 lm/mF

Grade DL (2nd Tier) · 23W/m

Grade DL (2nd Tier) · 23W/m — measured at 23 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K89.6 lm/W2060.8 lm/mF
2300 K99.9 lm/W2297.4 lm/mF80.9 lm/W1860.7 lm/mG
2700 K108.1 lm/W2485.8 lm/mF
3000 K113.7 lm/W2614.5 lm/mE
3500 K115.7 lm/W2660.4 lm/mE
4000 K118.5 lm/W2724.7 lm/mE
5000 K118.5 lm/W2724.7 lm/mE97.7 lm/W2247.1 lm/mF
6500 K113.6 lm/W2612.2 lm/mE94.3 lm/W2168.9 lm/mF

Grade DN (1st Tier) · 4.8W/m

Grade DN (1st Tier) · 4.8W/m — measured at 4.8 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K117.4 lm/W563.4 lm/mF
2300 K130.9 lm/W628.2 lm/mE106 lm/W508.8 lm/mF
2700 K141.7 lm/W680 lm/mE
3000 K149.6 lm/W718.1 lm/mD
3500 K152.9 lm/W733.9 lm/mD
4000 K153.7 lm/W737.7 lm/mD
5000 K154.7 lm/W742.6 lm/mD127.6 lm/W612.5 lm/mE
6500 K147.8 lm/W709.4 lm/mD122.7 lm/W589 lm/mE

Grade DN (1st Tier) · 9.6W/m

Grade DN (1st Tier) · 9.6W/m — measured at 9.6 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K113.5 lm/W1089.4 lm/mF
2300 K126.5 lm/W1214.8 lm/mE102.5 lm/W984 lm/mF
2700 K137 lm/W1314.9 lm/mE
3000 K144.6 lm/W1388.6 lm/mE
3500 K147.8 lm/W1419.2 lm/mD
4000 K148.6 lm/W1426.5 lm/mD
5000 K149.6 lm/W1436 lm/mD123.4 lm/W1184.6 lm/mE
6500 K142.9 lm/W1371.7 lm/mE118.6 lm/W1138.6 lm/mF

Grade DN (1st Tier) · 12W/m

Grade DN (1st Tier) · 12W/m — measured at 12 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K111.6 lm/W1339 lm/mF
2300 K124.4 lm/W1493.1 lm/mE100.8 lm/W1209.6 lm/mF
2700 K134.7 lm/W1616.1 lm/mE
3000 K142.2 lm/W1706.7 lm/mE
3500 K145.4 lm/W1744.3 lm/mE
4000 K146.1 lm/W1753.4 lm/mD
5000 K147.1 lm/W1765 lm/mD121.3 lm/W1455.6 lm/mE
6500 K140.5 lm/W1686 lm/mE116.6 lm/W1399.2 lm/mF

Grade DN (1st Tier) · 14.4W/m

Grade DN (1st Tier) · 14.4W/m — measured at 14.4 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K109.7 lm/W1579.9 lm/mF
2300 K122.3 lm/W1761.7 lm/mE99.1 lm/W1427 lm/mF
2700 K132.4 lm/W1906.9 lm/mE
3000 K139.9 lm/W2013.8 lm/mE
3500 K142.9 lm/W2058.2 lm/mE
4000 K143.7 lm/W2068.9 lm/mE
5000 K144.6 lm/W2082.6 lm/mE119.3 lm/W1717.9 lm/mE
6500 K138.2 lm/W1989.4 lm/mE114.7 lm/W1651.7 lm/mF

Grade DN (1st Tier) · 19.2W/m

Grade DN (1st Tier) · 19.2W/m — measured at 19.2 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K106.1 lm/W2036.7 lm/mF
2300 K118.3 lm/W2271.1 lm/mF95.8 lm/W1839.4 lm/mF
2700 K128 lm/W2458.2 lm/mE
3000 K135.2 lm/W2596.1 lm/mE
3500 K138.2 lm/W2653.2 lm/mE
4000 K138.9 lm/W2667 lm/mE
5000 K139.8 lm/W2684.7 lm/mE115.4 lm/W2215.7 lm/mF
6500 K133.6 lm/W2564.6 lm/mE110.9 lm/W2129.3 lm/mF

Grade DN (1st Tier) · 22.84W/m

Grade DN (1st Tier) · 22.84W/m — measured at 22.8 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K103.4 lm/W2361.3 lm/mF
2300 K115.3 lm/W2634.6 lm/mF93.4 lm/W2133.3 lm/mF
2700 K124.8 lm/W2851.2 lm/mE
3000 K131.8 lm/W3010.3 lm/mE
3500 K134.7 lm/W3075.7 lm/mE
4000 K135.4 lm/W3092.8 lm/mE
5000 K136.3 lm/W3113.1 lm/mE112.4 lm/W2567.2 lm/mF
6500 K130.2 lm/W2974.8 lm/mE108.1 lm/W2469 lm/mF

Grade DN (1st Tier) · 23W/m

Grade DN (1st Tier) · 23W/m — measured at 23 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K103.3 lm/W2375.5 lm/mF
2300 K115.2 lm/W2648.9 lm/mF93.3 lm/W2145.9 lm/mF
2700 K124.7 lm/W2867.2 lm/mE
3000 K131.7 lm/W3028 lm/mE
3500 K134.5 lm/W3094.6 lm/mE
4000 K135.2 lm/W3110.7 lm/mE
5000 K136.1 lm/W3131.4 lm/mE112.3 lm/W2582.9 lm/mF
6500 K130.1 lm/W2991.2 lm/mE107.9 lm/W2481.7 lm/mF

Grade KE (3rd Tier) · 4.8W/m

Grade KE (3rd Tier) · 4.8W/m — measured at 4.8 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K83.3 lm/W399.9 lm/mG
2300 K92.9 lm/W445.7 lm/mF75.2 lm/W361 lm/mG
2700 K100.7 lm/W483.3 lm/mF
3000 K106.5 lm/W511.1 lm/mF
3500 K108.6 lm/W521.4 lm/mF
4000 K110.9 lm/W532.3 lm/mE
5000 K110.9 lm/W532.3 lm/mE91.5 lm/W439.2 lm/mF
6500 K106.5 lm/W511.1 lm/mF88.4 lm/W424.3 lm/mF

Grade KE (3rd Tier) · 9.6W/m

Grade KE (3rd Tier) · 9.6W/m — measured at 9.6 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K80.6 lm/W773.3 lm/mG
2300 K89.8 lm/W861.8 lm/mF72.7 lm/W697.9 lm/mG
2700 K97.3 lm/W934.5 lm/mF
3000 K102.9 lm/W988.2 lm/mF
3500 K105 lm/W1008.3 lm/mF
4000 K107.2 lm/W1029.3 lm/mF
5000 K107.2 lm/W1029.3 lm/mF88.5 lm/W849.6 lm/mF
6500 K102.9 lm/W988.2 lm/mF85.4 lm/W819.8 lm/mF

Grade KE (3rd Tier) · 12W/m

Grade KE (3rd Tier) · 12W/m — measured at 12 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K79.2 lm/W950.5 lm/mG
2300 K88.3 lm/W1059.3 lm/mF71.5 lm/W858 lm/mG
2700 K95.7 lm/W1148.6 lm/mF
3000 K101.2 lm/W1214.7 lm/mF
3500 K103.3 lm/W1239.3 lm/mF
4000 K105.4 lm/W1265.2 lm/mF
5000 K105.4 lm/W1265.2 lm/mF87 lm/W1044 lm/mF
6500 K101.2 lm/W1214.7 lm/mF84 lm/W1008 lm/mG

Grade KE (3rd Tier) · 14.4W/m

Grade KE (3rd Tier) · 14.4W/m — measured at 14.4 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K77.9 lm/W1121.5 lm/mG
2300 K86.8 lm/W1249.9 lm/mF70.3 lm/W1012.3 lm/mG
2700 K94.1 lm/W1355.3 lm/mF
3000 K99.5 lm/W1433.2 lm/mF
3500 K101.5 lm/W1462.3 lm/mF
4000 K103.7 lm/W1492.8 lm/mF
5000 K103.7 lm/W1492.8 lm/mF85.5 lm/W1231.2 lm/mF
6500 K99.5 lm/W1433.2 lm/mF82.6 lm/W1189.4 lm/mG

Grade KE (3rd Tier) · 19.2W/m

Grade KE (3rd Tier) · 19.2W/m — measured at 19.2 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K75.3 lm/W1445.8 lm/mG
2300 K83.9 lm/W1611.2 lm/mG68 lm/W1305.6 lm/mG
2700 K91 lm/W1747.1 lm/mF
3000 K96.2 lm/W1847.6 lm/mF
3500 K98.2 lm/W1885 lm/mF
4000 K100.2 lm/W1924.4 lm/mF
5000 K100.2 lm/W1924.4 lm/mF82.7 lm/W1587.8 lm/mG
6500 K96.2 lm/W1847.6 lm/mF79.9 lm/W1534.1 lm/mG

Grade KE (3rd Tier) · 22.84W/m

Grade KE (3rd Tier) · 22.84W/m — measured at 22.8 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K73.4 lm/W1676.4 lm/mG
2300 K81.8 lm/W1868.2 lm/mG66.3 lm/W1514.3 lm/mG
2700 K88.7 lm/W2027 lm/mF
3000 K93.8 lm/W2142.4 lm/mF
3500 K95.7 lm/W2184.8 lm/mF
4000 K97.7 lm/W2231.5 lm/mF
5000 K97.7 lm/W2230.8 lm/mF80.6 lm/W1840.9 lm/mG
6500 K93.8 lm/W2141.6 lm/mF77.9 lm/W1779.2 lm/mG

Grade KE (3rd Tier) · 23W/m

Grade KE (3rd Tier) · 23W/m — measured at 23 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K73.3 lm/W1686.3 lm/mG
2300 K81.7 lm/W1879.3 lm/mG66.2 lm/W1522.6 lm/mG
2700 K88.6 lm/W2037.8 lm/mF
3000 K93.7 lm/W2155 lm/mF
3500 K95.6 lm/W2198.6 lm/mF
4000 K97.6 lm/W2244.6 lm/mF
5000 K97.6 lm/W2244.6 lm/mF80.5 lm/W1851.5 lm/mG
6500 K93.7 lm/W2155 lm/mF77.8 lm/W1789.4 lm/mG

Frequently Asked Questions

What are the key specifications of 3015-B?

3015-B: 2835, 128, 24V, 10 PCB, 3oz copper FPCB, cuttable 8LEDs/62.5mm. Full photometric data, wiring diagrams and test reports are available in the downloads section of this page.

What colour temperatures and CRI options does this 1 SDCM LED strip offer?

This model is supplied as a 1 SDCM LED strip with high CRI options and the CCT range listed in the datasheet. DENO bins every batch for colour consistency, and custom CCT or spectrum combinations can be produced for project quantities.

Can DENO customise this 1 SDCM LED strip for a project?

Yes. DENO manufactures the 1 SDCM SMD Strips series as an OEM and ODM supplier: reel length, colour temperature, CRI grade, PCB width, waterproofing and private labelling can all be specified. Request a quote for lead time and project pricing.

What does 1 SDCM mean on a high CRI LED strip?

1 SDCM means every LED falls inside one MacAdam ellipse, so no visible colour difference exists between reels or between fixtures. Combined with Ra>90 and R9>50, this high CRI LED strip keeps white points matched across a whole project, which matters in retail, museum and hospitality installations where several runs sit side by side.

1 SDCM LED Strip — Buyer Questions

What does 1 SDCM mean on an LED strip?

SDCM is the Standard Deviation of Colour Matching — the size of the MacAdam ellipse a batch's chromaticity falls inside. A 1 SDCM LED strip keeps every LED within one ellipse of the target point, which is below the threshold the human eye can resolve, so a wall wash reads as one continuous colour instead of a series of slightly different whites.

3 SDCM vs 1 SDCM — is the difference visible on a real installation?

On a single short run, rarely. On a long cove, a mirrored pair of coffers or two reels butted end to end, 3 SDCM shows as a visible pink-to-green drift between sections, while 1 SDCM does not. Specify 1 SDCM whenever two lit surfaces are seen at once, on white joinery, or in retail and gallery lighting where the colour of the merchandise is the product.

Will a re-order months later still match my installed 1 SDCM LED strip?

Yes, when the original batch reference is quoted on the purchase order. DENO archives the bin and reel data for each 1 SDCM build, so a replacement section or a phase-two extension is produced from the same bin instead of the current stock bin — the usual cause of a mismatched repair on architectural projects.

Which applications actually need a 1 SDCM LED strip?

Museum and gallery lighting, retail displays and cosmetics counters, hotel and residential coves with sightlines across several bays, film and photo studio fill, and any white-on-white joinery detail. For back-of-house, machine and signage work 3 SDCM is normally sufficient and the cheaper specification.