10mm | 24V | 120LEDs | 50mm/cut | #2176-B | 2835 1 SDCM Classic High Consistency LED Strip Light is part of the DENO 1 SDCM SMD Strips series, engineered around 1 SDCM LED strip. Key specifications: 2835, 120, 24V, 10 PCB, 3oz copper FPCB, cuttable 6LEDs/50mm, IP20/IP54/IP65/IP66/IP67/IP68, CRI Ra≥90. Every reel is produced on DENO's roll-to-roll line with 99.9% pure copper FPCB and ships CE, UL and RoHS compliant for architectural, retail and hospitality projects. OEM and ODM configurations of length, colour temperature and waterproofing are available on request.
Description
10mm | 24V | 120LEDs | 50mm/cut | #2176-B | 2835 1 SDCM Classic High Consistency LED Strip Light By adopting 1-Step (1 SDCM) binning LEDs, chromaticity tolerance is strictly controlled within one MacAdam Step at the source. Built on the classic 2835 SMD LED platform, this strip features 120 LEDs per meter, delivering stable output and smooth linear illumination. Compatible with multiple dimming systems including PWM, DALI, and 0–10V, the strip enables flexible and precise lighting control. Ideal for retail lighting, architectural lighting, display showcases, and high-end residential applications.
We use 99.99% gold wire, large-size chips, and thickened FPCB, backed by a 5-year warranty.
Specifications
| CCT (K) | 2700-6500 |
|---|---|
| CRI | Ra≥90 |
| SDCM | < 1 SDCM (Single Bin) |
| LED QTY | 120 |
| PART NO | DL-F28A60V24-2176-B-* |
| SMD TYPE | 2835 |
| CUTTABLE UNIT | 6LEDs/50mm |
| DIMMABLE | Yes |
| IP RATING | IP20/IP54/IP65/IP66/IP67/IP68 |
| LED PITCH | 8.3mm |
| LIFESPAN | 50000 |
| PCB WIDTH | 10 |
| WARRANTY | 5 Years |
| BEAM ANGLE | 120° |
| LENGTH MAX | 5m |
| COPPER FOIL | 3oz |
| CIRCUIT TYPE | C.V. |
| INPUT VOLTAGE | 24V |
| LUMINOUS FLUX | 1163 lm/m |
| OPERATING TEMPERATURE | -25~40°C;Tc:75°C(max) |
Photometric Performance — CCT × CRI Efficacy Matrix
Peak measured luminous efficacy: 116.5 lm/W at 5000K, Ra 90, ErP energy class F (Grade DN (1st Tier) · 9.6W/m).
All values are measured at the stated power density and ambient 25 °C, reported as luminous efficacy in lumens per watt (lm/W), luminous flux per metre (lm/m) and the corresponding EU ErP (2019/2015) energy class.
Grade DL (2nd Tier) · 9.6W/m
| CCT (K) | Ra 80 — Luminous Efficacy (lm/W) | Ra 80 — Luminous Flux (lm/m) | Ra 80 — ErP Energy Class | Ra 90 — Luminous Efficacy (lm/W) | Ra 90 — Luminous Flux (lm/m) | Ra 90 — ErP Energy Class | Full Spectrum (Ra 95+) — Luminous Efficacy (lm/W) | Full Spectrum (Ra 95+) — Luminous Flux (lm/m) | Full Spectrum (Ra 95+) — ErP Energy Class |
|---|---|---|---|---|---|---|---|---|---|
| 1800 K | — | — | — | 74.3 lm/W | 713 lm/m | G | — | — | — |
| 2300 K | — | — | — | 82.7 lm/W | 794.3 lm/m | G | — | — | — |
| 2700 K | — | — | — | 89.6 lm/W | 859.9 lm/m | F | — | — | — |
| 3000 K | — | — | — | 94.3 lm/W | 905 lm/m | F | — | — | — |
| 3500 K | — | — | — | 95.9 lm/W | 920.6 lm/m | F | — | — | — |
| 4000 K | — | — | — | 98.2 lm/W | 943.2 lm/m | F | — | — | — |
| 5000 K | — | — | — | 98.1 lm/W | 942.2 lm/m | F | — | — | — |
| 6500 K | — | — | — | 94.2 lm/W | 904 lm/m | F | — | — | — |
Grade DL (2nd Tier) · 12W/m
| CCT (K) | Ra 80 — Luminous Efficacy (lm/W) | Ra 80 — Luminous Flux (lm/m) | Ra 80 — ErP Energy Class | Ra 90 — Luminous Efficacy (lm/W) | Ra 90 — Luminous Flux (lm/m) | Ra 90 — ErP Energy Class | Full Spectrum (Ra 95+) — Luminous Efficacy (lm/W) | Full Spectrum (Ra 95+) — Luminous Flux (lm/m) | Full Spectrum (Ra 95+) — ErP Energy Class |
|---|---|---|---|---|---|---|---|---|---|
| 1800 K | — | — | — | 73 lm/W | 876.4 lm/m | G | — | — | — |
| 2300 K | — | — | — | 81.4 lm/W | 976.3 lm/m | G | — | — | — |
| 2700 K | — | — | — | 88.1 lm/W | 1056.9 lm/m | F | — | — | — |
| 3000 K | — | — | — | 92.7 lm/W | 1112.3 lm/m | F | — | — | — |
| 3500 K | — | — | — | 94.3 lm/W | 1131.6 lm/m | F | — | — | — |
| 4000 K | — | — | — | 96.6 lm/W | 1159.3 lm/m | F | — | — | — |
| 5000 K | — | — | — | 96.5 lm/W | 1158.1 lm/m | F | — | — | — |
| 6500 K | — | — | — | 92.6 lm/W | 1111.1 lm/m | F | — | — | — |
Grade DL (2nd Tier) · 14W/m
| CCT (K) | Ra 80 — Luminous Efficacy (lm/W) | Ra 80 — Luminous Flux (lm/m) | Ra 80 — ErP Energy Class | Ra 90 — Luminous Efficacy (lm/W) | Ra 90 — Luminous Flux (lm/m) | Ra 90 — ErP Energy Class | Full Spectrum (Ra 95+) — Luminous Efficacy (lm/W) | Full Spectrum (Ra 95+) — Luminous Flux (lm/m) | Full Spectrum (Ra 95+) — ErP Energy Class |
|---|---|---|---|---|---|---|---|---|---|
| 1800 K | — | — | — | 72 lm/W | 1008.2 lm/m | G | — | — | — |
| 2300 K | — | — | — | 80.2 lm/W | 1123.1 lm/m | G | — | — | — |
| 2700 K | — | — | — | 86.8 lm/W | 1215.9 lm/m | F | — | — | — |
| 3000 K | — | — | — | 91.4 lm/W | 1279.6 lm/m | F | — | — | — |
| 3500 K | — | — | — | 93 lm/W | 1301.7 lm/m | F | — | — | — |
| 4000 K | — | — | — | 95.3 lm/W | 1333.6 lm/m | F | — | — | — |
| 5000 K | — | — | — | 95.2 lm/W | 1332.2 lm/m | F | — | — | — |
| 6500 K | — | — | — | 91.3 lm/W | 1278.2 lm/m | F | — | — | — |
Grade DL (2nd Tier) · 19.2W/m
| CCT (K) | Ra 80 — Luminous Efficacy (lm/W) | Ra 80 — Luminous Flux (lm/m) | Ra 80 — ErP Energy Class | Ra 90 — Luminous Efficacy (lm/W) | Ra 90 — Luminous Flux (lm/m) | Ra 90 — ErP Energy Class | Full Spectrum (Ra 95+) — Luminous Efficacy (lm/W) | Full Spectrum (Ra 95+) — Luminous Flux (lm/m) | Full Spectrum (Ra 95+) — ErP Energy Class |
|---|---|---|---|---|---|---|---|---|---|
| 1800 K | — | — | — | 69.4 lm/W | 1333 lm/m | G | — | — | — |
| 2300 K | — | — | — | 77.3 lm/W | 1485 lm/m | G | — | — | — |
| 2700 K | — | — | — | 83.7 lm/W | 1607.7 lm/m | G | — | — | — |
| 3000 K | — | — | — | 88.1 lm/W | 1691.9 lm/m | F | — | — | — |
| 3500 K | — | — | — | 89.6 lm/W | 1721.2 lm/m | F | — | — | — |
| 4000 K | — | — | — | 91.8 lm/W | 1763.3 lm/m | F | — | — | — |
| 5000 K | — | — | — | 91.7 lm/W | 1761.5 lm/m | F | — | — | — |
| 6500 K | — | — | — | 88 lm/W | 1690.1 lm/m | F | — | — | — |
Grade DL (2nd Tier) · 24W/m
| CCT (K) | Ra 80 — Luminous Efficacy (lm/W) | Ra 80 — Luminous Flux (lm/m) | Ra 80 — ErP Energy Class | Ra 90 — Luminous Efficacy (lm/W) | Ra 90 — Luminous Flux (lm/m) | Ra 90 — ErP Energy Class | Full Spectrum (Ra 95+) — Luminous Efficacy (lm/W) | Full Spectrum (Ra 95+) — Luminous Flux (lm/m) | Full Spectrum (Ra 95+) — ErP Energy Class |
|---|---|---|---|---|---|---|---|---|---|
| 1800 K | — | — | — | 67.1 lm/W | 1611 lm/m | G | — | — | — |
| 2300 K | — | — | — | 74.8 lm/W | 1794.7 lm/m | G | — | — | — |
| 2700 K | — | — | — | 81 lm/W | 1943 lm/m | G | — | — | — |
| 3000 K | — | — | — | 85.2 lm/W | 2044.8 lm/m | F | — | — | — |
| 3500 K | — | — | — | 86.7 lm/W | 2080.2 lm/m | F | — | — | — |
| 4000 K | — | — | — | 88.8 lm/W | 2131.1 lm/m | F | — | — | — |
| 5000 K | — | — | — | 88.7 lm/W | 2128.9 lm/m | F | — | — | — |
| 6500 K | — | — | — | 85.1 lm/W | 2042.6 lm/m | F | — | — | — |
Grade DN (1st Tier) · 9.6W/m
| CCT (K) | Ra 80 — Luminous Efficacy (lm/W) | Ra 80 — Luminous Flux (lm/m) | Ra 80 — ErP Energy Class | Ra 90 — Luminous Efficacy (lm/W) | Ra 90 — Luminous Flux (lm/m) | Ra 90 — ErP Energy Class | Full Spectrum (Ra 95+) — Luminous Efficacy (lm/W) | Full Spectrum (Ra 95+) — Luminous Flux (lm/m) | Full Spectrum (Ra 95+) — ErP Energy Class |
|---|---|---|---|---|---|---|---|---|---|
| 1800 K | — | — | — | 88.4 lm/W | 848.2 lm/m | G | — | — | — |
| 2300 K | — | — | — | 98.6 lm/W | 946.1 lm/m | F | — | — | — |
| 2700 K | — | — | — | 106.6 lm/W | 1023.5 lm/m | F | — | — | — |
| 3000 K | — | — | — | 112.6 lm/W | 1081.3 lm/m | F | — | — | — |
| 3500 K | — | — | — | 115.1 lm/W | 1104.8 lm/m | F | — | — | — |
| 4000 K | — | — | — | 115.7 lm/W | 1110.7 lm/m | F | — | — | — |
| 5000 K | — | — | — | 116.5 lm/W | 1118.5 lm/m | F | — | — | — |
| 6500 K | — | — | — | 111.3 lm/W | 1068.5 lm/m | F | — | — | — |
Grade DN (1st Tier) · 12W/m
| CCT (K) | Ra 80 — Luminous Efficacy (lm/W) | Ra 80 — Luminous Flux (lm/m) | Ra 80 — ErP Energy Class | Ra 90 — Luminous Efficacy (lm/W) | Ra 90 — Luminous Flux (lm/m) | Ra 90 — ErP Energy Class | Full Spectrum (Ra 95+) — Luminous Efficacy (lm/W) | Full Spectrum (Ra 95+) — Luminous Flux (lm/m) | Full Spectrum (Ra 95+) — ErP Energy Class |
|---|---|---|---|---|---|---|---|---|---|
| 1800 K | — | — | — | 86.9 lm/W | 1042.5 lm/m | G | — | — | — |
| 2300 K | — | — | — | 96.9 lm/W | 1162.9 lm/m | F | — | — | — |
| 2700 K | — | — | — | 104.8 lm/W | 1258 lm/m | F | — | — | — |
| 3000 K | — | — | — | 110.7 lm/W | 1329 lm/m | F | — | — | — |
| 3500 K | — | — | — | 113.2 lm/W | 1357.9 lm/m | F | — | — | — |
| 4000 K | — | — | — | 113.8 lm/W | 1365.1 lm/m | F | — | — | — |
| 5000 K | — | — | — | 114.6 lm/W | 1374.7 lm/m | F | — | — | — |
| 6500 K | — | — | — | 109.4 lm/W | 1313.3 lm/m | F | — | — | — |
Grade DN (1st Tier) · 14W/m
| CCT (K) | Ra 80 — Luminous Efficacy (lm/W) | Ra 80 — Luminous Flux (lm/m) | Ra 80 — ErP Energy Class | Ra 90 — Luminous Efficacy (lm/W) | Ra 90 — Luminous Flux (lm/m) | Ra 90 — ErP Energy Class | Full Spectrum (Ra 95+) — Luminous Efficacy (lm/W) | Full Spectrum (Ra 95+) — Luminous Flux (lm/m) | Full Spectrum (Ra 95+) — ErP Energy Class |
|---|---|---|---|---|---|---|---|---|---|
| 1800 K | — | — | — | 85.7 lm/W | 1199.3 lm/m | G | — | — | — |
| 2300 K | — | — | — | 95.6 lm/W | 1337.8 lm/m | F | — | — | — |
| 2700 K | — | — | — | 103.4 lm/W | 1447.2 lm/m | F | — | — | — |
| 3000 K | — | — | — | 109.2 lm/W | 1528.9 lm/m | F | — | — | — |
| 3500 K | — | — | — | 111.6 lm/W | 1562.1 lm/m | F | — | — | — |
| 4000 K | — | — | — | 112.2 lm/W | 1570.4 lm/m | F | — | — | — |
| 5000 K | — | — | — | 113 lm/W | 1581.5 lm/m | F | — | — | — |
| 6500 K | — | — | — | 107.9 lm/W | 1510.9 lm/m | F | — | — | — |
Grade DN (1st Tier) · 19.2W/m
| CCT (K) | Ra 80 — Luminous Efficacy (lm/W) | Ra 80 — Luminous Flux (lm/m) | Ra 80 — ErP Energy Class | Ra 90 — Luminous Efficacy (lm/W) | Ra 90 — Luminous Flux (lm/m) | Ra 90 — ErP Energy Class | Full Spectrum (Ra 95+) — Luminous Efficacy (lm/W) | Full Spectrum (Ra 95+) — Luminous Flux (lm/m) | Full Spectrum (Ra 95+) — ErP Energy Class |
|---|---|---|---|---|---|---|---|---|---|
| 1800 K | — | — | — | 82.6 lm/W | 1585.7 lm/m | G | — | — | — |
| 2300 K | — | — | — | 92.1 lm/W | 1768.8 lm/m | F | — | — | — |
| 2700 K | — | — | — | 99.7 lm/W | 1913.5 lm/m | F | — | — | — |
| 3000 K | — | — | — | 105.3 lm/W | 2021.5 lm/m | F | — | — | — |
| 3500 K | — | — | — | 107.6 lm/W | 2065.5 lm/m | F | — | — | — |
| 4000 K | — | — | — | 108.1 lm/W | 2076.5 lm/m | F | — | — | — |
| 5000 K | — | — | — | 108.9 lm/W | 2091.1 lm/m | F | — | — | — |
| 6500 K | — | — | — | 104 lm/W | 1997.7 lm/m | F | — | — | — |
Grade DN (1st Tier) · 24W/m
| CCT (K) | Ra 80 — Luminous Efficacy (lm/W) | Ra 80 — Luminous Flux (lm/m) | Ra 80 — ErP Energy Class | Ra 90 — Luminous Efficacy (lm/W) | Ra 90 — Luminous Flux (lm/m) | Ra 90 — ErP Energy Class | Full Spectrum (Ra 95+) — Luminous Efficacy (lm/W) | Full Spectrum (Ra 95+) — Luminous Flux (lm/m) | Full Spectrum (Ra 95+) — ErP Energy Class |
|---|---|---|---|---|---|---|---|---|---|
| 1800 K | — | — | — | 79.9 lm/W | 1916.4 lm/m | G | — | — | — |
| 2300 K | — | — | — | 89.1 lm/W | 2137.7 lm/m | G | — | — | — |
| 2700 K | — | — | — | 96.4 lm/W | 2312.6 lm/m | F | — | — | — |
| 3000 K | — | — | — | 101.8 lm/W | 2443.1 lm/m | F | — | — | — |
| 3500 K | — | — | — | 104 lm/W | 2496.2 lm/m | F | — | — | — |
| 4000 K | — | — | — | 104.6 lm/W | 2509.5 lm/m | F | — | — | — |
| 5000 K | — | — | — | 105.3 lm/W | 2527.2 lm/m | F | — | — | — |
| 6500 K | — | — | — | 100.6 lm/W | 2414.3 lm/m | F | — | — | — |
Frequently Asked Questions
What are the key specifications of 2176-B?
2176-B: 2835, 120, 24V, 10 PCB, 3oz copper FPCB, cuttable 6LEDs/50mm, IP20/IP54/IP65/IP66/IP67/IP68, CRI Ra≥90. Full photometric data, wiring diagrams and test reports are available in the downloads section of this page.
What colour temperatures and CRI options does this 1 SDCM LED strip offer?
This model is supplied as a 1 SDCM LED strip with CRI Ra≥90 and 2700-6500 colour temperature options. DENO bins every batch for colour consistency, and custom CCT or spectrum combinations can be produced for project quantities.
Can DENO customise this 1 SDCM LED strip for a project?
Yes. DENO manufactures the 1 SDCM SMD Strips series as an OEM and ODM supplier: reel length, colour temperature, CRI grade, PCB width, waterproofing and private labelling can all be specified. Request a quote for lead time and project pricing.
What does 1 SDCM mean on a high CRI LED strip?
1 SDCM means every LED falls inside one MacAdam ellipse, so no visible colour difference exists between reels or between fixtures. Combined with Ra>90 and R9>50, this high CRI LED strip keeps white points matched across a whole project, which matters in retail, museum and hospitality installations where several runs sit side by side.
1 SDCM LED Strip — Buyer Questions
What does 1 SDCM mean on an LED strip?
SDCM is the Standard Deviation of Colour Matching — the size of the MacAdam ellipse a batch's chromaticity falls inside. A 1 SDCM LED strip keeps every LED within one ellipse of the target point, which is below the threshold the human eye can resolve, so a wall wash reads as one continuous colour instead of a series of slightly different whites.
- Series 1 SDCM LED Strips series
- Guide LED binning and chromaticity control
- Related series full spectrum LED strip for high-CRI white
3 SDCM vs 1 SDCM — is the difference visible on a real installation?
On a single short run, rarely. On a long cove, a mirrored pair of coffers or two reels butted end to end, 3 SDCM shows as a visible pink-to-green drift between sections, while 1 SDCM does not. Specify 1 SDCM whenever two lit surfaces are seen at once, on white joinery, or in retail and gallery lighting where the colour of the merchandise is the product.
- Series 1 SDCM LED Strips series
- Related series high density LED strip boards for seamless coves
- Guide CCT × CRI efficacy matrix data
How does DENO hold 1 SDCM colour consistency across a production batch?
Three controls stack: single-bin LED sourcing from one wafer lot, in-line chromaticity sampling on the SMT line, and reel-level records so a repeat order can be matched to the original batch. Boards outside the ellipse are pulled before packing rather than blended into the run.
Will a re-order months later still match my installed 1 SDCM LED strip?
Yes, when the original batch reference is quoted on the purchase order. DENO archives the bin and reel data for each 1 SDCM build, so a replacement section or a phase-two extension is produced from the same bin instead of the current stock bin — the usual cause of a mismatched repair on architectural projects.
- Series 1 SDCM LED Strips series
- Guide quote a repeat 1 SDCM batch
- Related series custom LED strip lights built to order
- Product 16705 24V high consistency LED strip
Does tight colour binning affect brightness or efficacy?
Not measurably. Binning narrows chromaticity, not flux: a 1 SDCM board is drawn from the same flux bin as the standard build, so lm/W and lm/m stay on the published matrix. What does change is yield, which is why colour-critical builds carry a small premium over 3 SDCM tape.
Which applications actually need a 1 SDCM LED strip?
Museum and gallery lighting, retail displays and cosmetics counters, hotel and residential coves with sightlines across several bays, film and photo studio fill, and any white-on-white joinery detail. For back-of-house, machine and signage work 3 SDCM is normally sufficient and the cheaper specification.
- Series 1 SDCM LED Strips series
- Related series long LED strip lights series
- Related series constant current LED strip series
- Product 16706 1 SDCM SMD LED strip