2835 Super Long Constant Current Light Strips (#20441)
5mm · 24V · 120LEDs · 41.667mm/cut
Model: 20441

Overview
2835 Super Long Constant Current Light Strips | 5mm | 24V | 120LEDs | 41.667mm/cut | #20441 is part of the DENO Ultra-Long SMD Strips series, engineered around ultra long run LED strip. Key specifications: 2835, 120, DC 24V, 5mm PCB, 3oz copper FPCB, cuttable 5LEDs/41.667. Every reel is produced on DENO's roll-to-roll line with 99.9% pure copper FPCB and ships CE, UL and RoHS compliant for architectural, retail and hospitality projects. OEM and ODM configurations of length, colour temperature and waterproofing are available on request.
Description
2835 long LED strip — 24V DC, 120 LEDs/m on a 5mm, 3 oz copper board, cuttable every 41.67mm, constant-current circuit. Buyer decision: a 5mm board that still runs 15 m (49 ft) on one feed and 30 m on two — the CC circuit compensates for the narrow copper, so slim joinery and handrail channels get even light over their full length. Custom CCT, IP and length — request a factory quote.
Constant Current Ic Led Strip built for c.c. smd strips (ic regulated) projects.
Specifications
| LED QTY | 120 |
|---|---|
| PART NO | DL-F28A60V24-20441 |
| SMD TYPE | 2835 |
| CUTTABLE UNIT | 5LEDs/41.667 |
| DIMMABLE | Yes |
| LED PITCH | 8.333mm |
| PCB WIDTH | 5mm |
| LENGTH MAX | 15m |
| COPPER FOIL | 3oz |
| POWER RANGE | 3~8W |
| CIRCUIT TYPE | C.C. |
| INPUT VOLTAGE | DC 24V |
Photometric Performance — CCT × CRI Efficacy Matrix
Peak measured luminous efficacy: 130.4 lm/W at 4000K, Ra 80, ErP energy class E (Grade DN (1st Tier) · 3W/m).
All values are measured at the stated power density and ambient 25 °C, reported as luminous efficacy in lumens per watt (lm/W), luminous flux per metre (lm/m) and the corresponding EU ErP (2019/2015) energy class.
Grade DL (2nd Tier) · 3W/m
| CCT (K) | Ra 80 — Luminous Efficacy (lm/W) | Ra 80 — Luminous Flux (lm/m) | Ra 80 — ErP Energy Class | Ra 90 — Luminous Efficacy (lm/W) | Ra 90 — Luminous Flux (lm/m) | Ra 90 — ErP Energy Class | Full Spectrum (Ra 95+) — Luminous Efficacy (lm/W) | Full Spectrum (Ra 95+) — Luminous Flux (lm/m) | Full Spectrum (Ra 95+) — ErP Energy Class |
|---|---|---|---|---|---|---|---|---|---|
| 1800 K | 89.7 lm/W | 269.1 lm/m | F | 71.6 lm/W | 214.7 lm/m | G | — | — | — |
| 2300 K | 99.8 lm/W | 299.5 lm/m | F | 79.8 lm/W | 239.3 lm/m | G | 64.6 lm/W | 193.8 lm/m | G |
| 2700 K | 104.6 lm/W | 313.7 lm/m | F | 86.3 lm/W | 258.8 lm/m | F | 69.9 lm/W | 209.8 lm/m | G |
| 3000 K | 112.3 lm/W | 337 lm/m | E | 90.8 lm/W | 272.5 lm/m | F | 73.9 lm/W | 221.6 lm/m | G |
| 3500 K | 114.1 lm/W | 342.3 lm/m | E | 92.4 lm/W | 277.1 lm/m | F | 76 lm/W | 228.1 lm/m | G |
| 4000 K | 117.7 lm/W | 353.2 lm/m | E | 94.7 lm/W | 284 lm/m | F | 78.1 lm/W | 234.3 lm/m | G |
| 5000 K | 117.6 lm/W | 352.8 lm/m | E | 94.5 lm/W | 283.6 lm/m | F | 78 lm/W | 234 lm/m | G |
| 6500 K | 107.4 lm/W | 322.1 lm/m | F | 90.7 lm/W | 272.2 lm/m | F | 75.3 lm/W | 225.9 lm/m | G |
Grade DL (2nd Tier) · 5.8W/m
| CCT (K) | Ra 80 — Luminous Efficacy (lm/W) | Ra 80 — Luminous Flux (lm/m) | Ra 80 — ErP Energy Class | Ra 90 — Luminous Efficacy (lm/W) | Ra 90 — Luminous Flux (lm/m) | Ra 90 — ErP Energy Class | Full Spectrum (Ra 95+) — Luminous Efficacy (lm/W) | Full Spectrum (Ra 95+) — Luminous Flux (lm/m) | Full Spectrum (Ra 95+) — ErP Energy Class |
|---|---|---|---|---|---|---|---|---|---|
| 1800 K | 87.9 lm/W | 510 lm/m | F | 70.2 lm/W | 407.1 lm/m | G | — | — | — |
| 2300 K | 97.9 lm/W | 567.7 lm/m | F | 78.2 lm/W | 453.6 lm/m | G | 63.3 lm/W | 367.1 lm/m | G |
| 2700 K | 102.5 lm/W | 594.8 lm/m | F | 84.6 lm/W | 490.6 lm/m | G | 68.6 lm/W | 397.7 lm/m | G |
| 3000 K | 110.2 lm/W | 638.9 lm/m | E | 89.1 lm/W | 516.5 lm/m | F | 72.4 lm/W | 420 lm/m | G |
| 3500 K | 111.9 lm/W | 648.9 lm/m | E | 90.6 lm/W | 525.3 lm/m | F | 74.5 lm/W | 432.4 lm/m | G |
| 4000 K | 115.4 lm/W | 669.5 lm/m | E | 92.8 lm/W | 538.3 lm/m | F | 76.6 lm/W | 444.2 lm/m | G |
| 5000 K | 115.3 lm/W | 668.9 lm/m | E | 92.7 lm/W | 537.7 lm/m | F | 76.5 lm/W | 443.7 lm/m | G |
| 6500 K | 105.3 lm/W | 610.6 lm/m | F | 89 lm/W | 515.9 lm/m | F | 73.8 lm/W | 428 lm/m | G |
Grade DL (2nd Tier) · 8W/m
| CCT (K) | Ra 80 — Luminous Efficacy (lm/W) | Ra 80 — Luminous Flux (lm/m) | Ra 80 — ErP Energy Class | Ra 90 — Luminous Efficacy (lm/W) | Ra 90 — Luminous Flux (lm/m) | Ra 90 — ErP Energy Class | Full Spectrum (Ra 95+) — Luminous Efficacy (lm/W) | Full Spectrum (Ra 95+) — Luminous Flux (lm/m) | Full Spectrum (Ra 95+) — ErP Energy Class |
|---|---|---|---|---|---|---|---|---|---|
| 1800 K | 86.6 lm/W | 692.7 lm/m | F | 69.1 lm/W | 552.9 lm/m | G | — | — | — |
| 2300 K | 96.4 lm/W | 771 lm/m | F | 77 lm/W | 616 lm/m | G | 62.4 lm/W | 499.2 lm/m | G |
| 2700 K | 101 lm/W | 807.8 lm/m | F | 83.3 lm/W | 666.4 lm/m | G | 67.5 lm/W | 540.1 lm/m | G |
| 3000 K | 108.5 lm/W | 867.7 lm/m | F | 87.7 lm/W | 701.5 lm/m | F | 71.3 lm/W | 570.5 lm/m | G |
| 3500 K | 110.2 lm/W | 881.3 lm/m | E | 89.2 lm/W | 713.5 lm/m | F | 73.4 lm/W | 587.3 lm/m | G |
| 4000 K | 113.7 lm/W | 909.2 lm/m | E | 91.4 lm/W | 731.1 lm/m | F | 75.4 lm/W | 603.2 lm/m | G |
| 5000 K | 113.6 lm/W | 908.4 lm/m | E | 91.3 lm/W | 730.3 lm/m | F | 75.3 lm/W | 602.4 lm/m | G |
| 6500 K | 103.7 lm/W | 829.3 lm/m | F | 87.6 lm/W | 700.7 lm/m | F | 72.7 lm/W | 581.6 lm/m | G |
Grade DN (1st Tier) · 3W/m
| CCT (K) | Ra 80 — Luminous Efficacy (lm/W) | Ra 80 — Luminous Flux (lm/m) | Ra 80 — ErP Energy Class | Ra 90 — Luminous Efficacy (lm/W) | Ra 90 — Luminous Flux (lm/m) | Ra 90 — ErP Energy Class | Full Spectrum (Ra 95+) — Luminous Efficacy (lm/W) | Full Spectrum (Ra 95+) — Luminous Flux (lm/m) | Full Spectrum (Ra 95+) — ErP Energy Class |
|---|---|---|---|---|---|---|---|---|---|
| 1800 K | 102.2 lm/W | 306.6 lm/m | F | 85.9 lm/W | 257.6 lm/m | G | — | — | — |
| 2300 K | 111.4 lm/W | 334.2 lm/m | F | 95.8 lm/W | 287.4 lm/m | F | 77.6 lm/W | 232.8 lm/m | G |
| 2700 K | 120.1 lm/W | 360.3 lm/m | E | 103.6 lm/W | 310.9 lm/m | F | 84 lm/W | 252 lm/m | G |
| 3000 K | 126.2 lm/W | 378.6 lm/m | E | 109.4 lm/W | 328.3 lm/m | F | 89 lm/W | 266.9 lm/m | G |
| 3500 K | 128.1 lm/W | 384.2 lm/m | E | 111.8 lm/W | 335.5 lm/m | F | 92.1 lm/W | 276.2 lm/m | F |
| 4000 K | 130.4 lm/W | 391.3 lm/m | E | 112.4 lm/W | 337.3 lm/m | F | 92.8 lm/W | 278.4 lm/m | F |
| 5000 K | 130.2 lm/W | 390.7 lm/m | E | 113.2 lm/W | 339.5 lm/m | F | 93.4 lm/W | 280.2 lm/m | F |
| 6500 K | 124.9 lm/W | 374.6 lm/m | E | 108.2 lm/W | 324.6 lm/m | F | 89.8 lm/W | 269.4 lm/m | G |
Grade DN (1st Tier) · 5.8W/m
| CCT (K) | Ra 80 — Luminous Efficacy (lm/W) | Ra 80 — Luminous Flux (lm/m) | Ra 80 — ErP Energy Class | Ra 90 — Luminous Efficacy (lm/W) | Ra 90 — Luminous Flux (lm/m) | Ra 90 — ErP Energy Class | Full Spectrum (Ra 95+) — Luminous Efficacy (lm/W) | Full Spectrum (Ra 95+) — Luminous Flux (lm/m) | Full Spectrum (Ra 95+) — ErP Energy Class |
|---|---|---|---|---|---|---|---|---|---|
| 1800 K | 100.2 lm/W | 581.2 lm/m | F | 84.2 lm/W | 488.3 lm/m | G | — | — | — |
| 2300 K | 109.2 lm/W | 633.6 lm/m | F | 93.9 lm/W | 544.8 lm/m | F | 76.1 lm/W | 441.4 lm/m | G |
| 2700 K | 117.8 lm/W | 683 lm/m | F | 101.6 lm/W | 589.5 lm/m | F | 82.4 lm/W | 477.7 lm/m | G |
| 3000 K | 123.7 lm/W | 717.7 lm/m | E | 107.3 lm/W | 622.4 lm/m | F | 87.2 lm/W | 505.9 lm/m | G |
| 3500 K | 125.6 lm/W | 728.3 lm/m | E | 109.6 lm/W | 635.9 lm/m | F | 90.3 lm/W | 523.6 lm/m | G |
| 4000 K | 127.9 lm/W | 741.8 lm/m | E | 110.3 lm/W | 639.5 lm/m | F | 91 lm/W | 527.7 lm/m | G |
| 5000 K | 127.7 lm/W | 740.7 lm/m | E | 111 lm/W | 643.6 lm/m | F | 91.5 lm/W | 530.7 lm/m | G |
| 6500 K | 122.4 lm/W | 710.1 lm/m | E | 106.1 lm/W | 615.3 lm/m | F | 88.1 lm/W | 511 lm/m | G |
Grade DN (1st Tier) · 8W/m
| CCT (K) | Ra 80 — Luminous Efficacy (lm/W) | Ra 80 — Luminous Flux (lm/m) | Ra 80 — ErP Energy Class | Ra 90 — Luminous Efficacy (lm/W) | Ra 90 — Luminous Flux (lm/m) | Ra 90 — ErP Energy Class | Full Spectrum (Ra 95+) — Luminous Efficacy (lm/W) | Full Spectrum (Ra 95+) — Luminous Flux (lm/m) | Full Spectrum (Ra 95+) — ErP Energy Class |
|---|---|---|---|---|---|---|---|---|---|
| 1800 K | 98.7 lm/W | 789.4 lm/m | F | 82.9 lm/W | 663.2 lm/m | G | — | — | — |
| 2300 K | 107.6 lm/W | 860.5 lm/m | F | 92.5 lm/W | 739.9 lm/m | F | 74.9 lm/W | 599.2 lm/m | G |
| 2700 K | 116 lm/W | 927.6 lm/m | F | 100.1 lm/W | 800.6 lm/m | F | 81.1 lm/W | 648.8 lm/m | G |
| 3000 K | 121.8 lm/W | 974.8 lm/m | E | 105.7 lm/W | 845.3 lm/m | F | 85.9 lm/W | 687.1 lm/m | G |
| 3500 K | 123.6 lm/W | 989.1 lm/m | E | 108 lm/W | 863.7 lm/m | F | 88.9 lm/W | 711.1 lm/m | G |
| 4000 K | 125.9 lm/W | 1007.5 lm/m | E | 108.6 lm/W | 868.5 lm/m | F | 89.6 lm/W | 716.7 lm/m | G |
| 5000 K | 125.7 lm/W | 1005.9 lm/m | E | 109.3 lm/W | 874.1 lm/m | F | 90.1 lm/W | 720.8 lm/m | G |
| 6500 K | 120.5 lm/W | 964.4 lm/m | E | 104.5 lm/W | 835.7 lm/m | F | 86.7 lm/W | 693.6 lm/m | G |
Grade KE (3rd Tier) · 3W/m
| CCT (K) | Ra 80 — Luminous Efficacy (lm/W) | Ra 80 — Luminous Flux (lm/m) | Ra 80 — ErP Energy Class | Ra 90 — Luminous Efficacy (lm/W) | Ra 90 — Luminous Flux (lm/m) | Ra 90 — ErP Energy Class | Full Spectrum (Ra 95+) — Luminous Efficacy (lm/W) | Full Spectrum (Ra 95+) — Luminous Flux (lm/m) | Full Spectrum (Ra 95+) — ErP Energy Class |
|---|---|---|---|---|---|---|---|---|---|
| 1900 K | 69.1 lm/W | 207.3 lm/m | G | 54.8 lm/W | 164.5 lm/m | G | — | — | — |
| 2300 K | 77 lm/W | 230.9 lm/m | G | 61.1 lm/W | 183.4 lm/m | G | 49.5 lm/W | 148.5 lm/m | G |
| 2700 K | 83 lm/W | 248.9 lm/m | G | 66.3 lm/W | 198.9 lm/m | G | 53.7 lm/W | 161.1 lm/m | G |
| 3000 K | 87.1 lm/W | 261.3 lm/m | F | 70.1 lm/W | 210.4 lm/m | G | 57 lm/W | 171 lm/m | G |
| 3500 K | 88.4 lm/W | 265.3 lm/m | F | 71.5 lm/W | 214.4 lm/m | G | 58.9 lm/W | 176.6 lm/m | G |
| 4000 K | 91 lm/W | 273.1 lm/m | F | 73 lm/W | 219.1 lm/m | G | 60.3 lm/W | 180.9 lm/m | G |
| 5000 K | 90.9 lm/W | 272.8 lm/m | F | 73 lm/W | 219.1 lm/m | G | 60.3 lm/W | 180.9 lm/m | G |
| 6500 K | 87.1 lm/W | 261.3 lm/m | F | 70.1 lm/W | 210.4 lm/m | G | 58.2 lm/W | 174.6 lm/m | G |
Grade KE (3rd Tier) · 5.8W/m
| CCT (K) | Ra 80 — Luminous Efficacy (lm/W) | Ra 80 — Luminous Flux (lm/m) | Ra 80 — ErP Energy Class | Ra 90 — Luminous Efficacy (lm/W) | Ra 90 — Luminous Flux (lm/m) | Ra 90 — ErP Energy Class | Full Spectrum (Ra 95+) — Luminous Efficacy (lm/W) | Full Spectrum (Ra 95+) — Luminous Flux (lm/m) | Full Spectrum (Ra 95+) — ErP Energy Class |
|---|---|---|---|---|---|---|---|---|---|
| 1900 K | 67.8 lm/W | 393 lm/m | G | 53.8 lm/W | 311.8 lm/m | G | — | — | — |
| 2300 K | 75.5 lm/W | 437.7 lm/m | G | 59.9 lm/W | 347.7 lm/m | G | 48.6 lm/W | 281.9 lm/m | G |
| 2700 K | 81.3 lm/W | 471.8 lm/m | G | 65 lm/W | 377.1 lm/m | G | 52.6 lm/W | 305.3 lm/m | G |
| 3000 K | 85.4 lm/W | 495.3 lm/m | F | 68.8 lm/W | 398.9 lm/m | G | 55.9 lm/W | 324.1 lm/m | G |
| 3500 K | 86.7 lm/W | 503 lm/m | F | 70.1 lm/W | 406.5 lm/m | G | 57.7 lm/W | 334.7 lm/m | G |
| 4000 K | 89.3 lm/W | 517.7 lm/m | F | 71.6 lm/W | 415.3 lm/m | G | 59.1 lm/W | 343 lm/m | G |
| 5000 K | 89.2 lm/W | 517.1 lm/m | F | 71.6 lm/W | 415.3 lm/m | G | 59.1 lm/W | 342.8 lm/m | G |
| 6500 K | 85.4 lm/W | 495.3 lm/m | F | 68.8 lm/W | 398.9 lm/m | G | 57.1 lm/W | 331.2 lm/m | G |
Grade KE (3rd Tier) · 8W/m
| CCT (K) | Ra 80 — Luminous Efficacy (lm/W) | Ra 80 — Luminous Flux (lm/m) | Ra 80 — ErP Energy Class | Ra 90 — Luminous Efficacy (lm/W) | Ra 90 — Luminous Flux (lm/m) | Ra 90 — ErP Energy Class | Full Spectrum (Ra 95+) — Luminous Efficacy (lm/W) | Full Spectrum (Ra 95+) — Luminous Flux (lm/m) | Full Spectrum (Ra 95+) — ErP Energy Class |
|---|---|---|---|---|---|---|---|---|---|
| 1900 K | 66.7 lm/W | 533.7 lm/m | G | 52.9 lm/W | 423.5 lm/m | G | — | — | — |
| 2300 K | 74.3 lm/W | 594.4 lm/m | G | 59 lm/W | 472.2 lm/m | G | 47.8 lm/W | 382.4 lm/m | G |
| 2700 K | 80.1 lm/W | 640.8 lm/m | G | 64 lm/W | 512.1 lm/m | G | 51.8 lm/W | 414.7 lm/m | G |
| 3000 K | 84.1 lm/W | 672.7 lm/m | G | 67.7 lm/W | 541.7 lm/m | G | 55 lm/W | 440.2 lm/m | G |
| 3500 K | 85.4 lm/W | 683.1 lm/m | F | 69 lm/W | 552.1 lm/m | G | 56.8 lm/W | 454.6 lm/m | G |
| 4000 K | 87.9 lm/W | 703.1 lm/m | F | 70.5 lm/W | 564.1 lm/m | G | 58.2 lm/W | 465.8 lm/m | G |
| 5000 K | 87.8 lm/W | 702.3 lm/m | F | 70.5 lm/W | 564.1 lm/m | G | 58.2 lm/W | 465.6 lm/m | G |
| 6500 K | 84.1 lm/W | 672.7 lm/m | G | 67.7 lm/W | 541.7 lm/m | G | 56.2 lm/W | 449.6 lm/m | G |
Frequently Asked Questions
What are the key specifications of 20441?
20441: 2835, 120, DC 24V, 5mm PCB, 3oz copper FPCB, cuttable 5LEDs/41.667. Full photometric data, wiring diagrams and test reports are available in the downloads section of this page.
How long can a single run of this ultra long run LED strip be?
Maximum single run for this model is 15m. Feeding from both ends or using a mid-point tap halves the effective distance per segment, so a ultra long run LED strip can cover twice that length on one circuit when wired accordingly.
Can DENO customise this ultra long run LED strip for a project?
Yes. DENO manufactures the Ultra-Long SMD Strips series as an OEM and ODM supplier: reel length, colour temperature, CRI grade, PCB width, waterproofing and private labelling can all be specified. Request a quote for lead time and project pricing.
Does a constant current LED strip really eliminate voltage drop?
Voltage still drops along the copper, but the per-segment constant current IC holds LED current fixed until the local voltage falls below its dropout point. Brightness therefore stays even end to end, and power can be injected at one end, both ends or any mid point of the run.
What limits how long an LED strip run can be?
Voltage drop and conductor current, not the LED itself. A long run LED strip combines low watts per metre, 2 oz or thicker copper and a higher bus voltage such as 24V, 36V or 48V to reach 20 m or more from one feed while staying inside a 3 percent drop.
Constant Current LED Strip — Buyer Questions
What is a constant current LED strip?
A constant current LED strip carries a linear CC driver IC on the board that holds a fixed current through each segment regardless of the input voltage seen at that point. Brightness therefore stays flat along the run, instead of falling off with voltage drop the way a plain constant-voltage strip does.
Constant current vs constant voltage LED strip — which is better?
Constant voltage is cheaper and fine for short runs under 3 m. Constant current is the right choice whenever the run is long, the copper is thin, the input voltage is unstable, or the installation is camera-facing — the IC absorbs supply variation and keeps every metre at the same luminous flux.
Can a constant current LED strip be powered from both ends or mid-feed?
Yes. Because regulation happens per segment, DENO's CC boards accept single-end, both-ends and any mid-strip tap. Both-ends and mid-feed wiring halve the effective feed distance, which is how a single driver covers a long corridor or perimeter cove.
- Series constant current LED strip series
- Guide wiring layout planner for mid-feed CC runs
- Related series long-run CC LED strip builds
- Product 3348 mid-feed constant current LED strip
Does a constant current LED strip dim without flicker?
It does when the driver is matched to it. Linear CC ICs dim smoothly on PWM down to about 1%, and at 16 kHz+ PWM the run is flicker-free on camera (low Pst LM and SVM). Analogue dimming of a CC board is not recommended below 20% because the IC needs headroom.
- Series constant current LED strip series
- Guide flicker, Pst LM and SVM reference data
- Related series high-CRI boards for camera-facing work
How long can a constant current LED strip run be?
Up to 20 m and beyond on 24V or 48V builds with 2 oz copper, versus 5 m for a comparable constant-voltage board. The practical limit becomes the copper's current-carrying capacity and thermal design rather than perceived brightness fall-off.
Can I order a custom constant current LED strip?
Yes — segment length, drive current, voltage, LED density, CCT/CRI, PCB width and copper weight are all configurable, and CC regulation can be combined with high-density, ultra-narrow or full-spectrum layouts on the same board.
- Series constant current LED strip series
- Related series custom LED strip lights built to order
- Related series combine CC drive with high density layouts
Long LED Strip Lights — Buyer Questions
How long can a long LED strip run be on a single power feed?
A standard 24V constant-voltage tape is limited to about 5 m before the far end visibly dims. DENO's long-run boards combine 2 oz to 3 oz copper, 24V or 48V input and per-segment constant-current ICs, which takes a single feed to 20 m, and up to 50 m on 48V builds, with no measurable fall-off between the first and last metre.
What are the longest LED light strips DENO manufactures?
Standard reels ship at 5 m, 10 m, 15 m, 20 m and 30 m, and OEM orders are produced as one continuous 50 m board with no mid-reel solder joint. Roll-to-roll plating is what makes that possible: the copper is deposited continuously, so length is not capped by panel size the way it is on die-cut FPCB.
- Series long LED strip lights series
- Guide roll-to-roll process behind continuous long boards
- Related series roll-to-roll LED strip series
- Product 5164 long LED strip reel
Why do long strip lights get dimmer at the far end, and how is it fixed?
Copper resistance drops the supply voltage along the tape, so LEDs near the end of the run receive less drive current. Three fixes work together: raise the voltage (24V, 36V or 48V), raise the copper weight (2 oz or 3 oz), and add a linear constant-current IC per segment so each segment holds its current regardless of the local voltage it sees.
- Series long LED strip lights series
- Related series constant current LED strip boards
- Guide copper weight and voltage drop explained
- Product 4493 constant current long-run LED strip