Overview

2835 Super Long Constant Current Light Strips | 5mm | 24V | 120LEDs | 41.667mm/cut | #20441 is part of the DENO Ultra-Long SMD Strips series, engineered around ultra long run LED strip. Key specifications: 2835, 120, DC 24V, 5mm PCB, 3oz copper FPCB, cuttable 5LEDs/41.667. Every reel is produced on DENO's roll-to-roll line with 99.9% pure copper FPCB and ships CE, UL and RoHS compliant for architectural, retail and hospitality projects. OEM and ODM configurations of length, colour temperature and waterproofing are available on request.

Description

2835 long LED strip — 24V DC, 120 LEDs/m on a 5mm, 3 oz copper board, cuttable every 41.67mm, constant-current circuit. Buyer decision: a 5mm board that still runs 15 m (49 ft) on one feed and 30 m on two — the CC circuit compensates for the narrow copper, so slim joinery and handrail channels get even light over their full length. Custom CCT, IP and length — request a factory quote.

Constant Current Ic Led Strip built for c.c. smd strips (ic regulated) projects.

Specifications

LED QTY120
PART NODL-F28A60V24-20441
SMD TYPE2835
CUTTABLE UNIT5LEDs/41.667
DIMMABLEYes
LED PITCH8.333mm
PCB WIDTH5mm
LENGTH MAX15m
COPPER FOIL3oz
POWER RANGE3~8W
CIRCUIT TYPEC.C.
INPUT VOLTAGEDC 24V

Photometric Performance — CCT × CRI Efficacy Matrix

Peak measured luminous efficacy: 130.4 lm/W at 4000K, Ra 80, ErP energy class E (Grade DN (1st Tier) · 3W/m).

All values are measured at the stated power density and ambient 25 °C, reported as luminous efficacy in lumens per watt (lm/W), luminous flux per metre (lm/m) and the corresponding EU ErP (2019/2015) energy class.

Grade DL (2nd Tier) · 3W/m

Grade DL (2nd Tier) · 3W/m — measured at 3 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K89.7 lm/W269.1 lm/mF71.6 lm/W214.7 lm/mG
2300 K99.8 lm/W299.5 lm/mF79.8 lm/W239.3 lm/mG64.6 lm/W193.8 lm/mG
2700 K104.6 lm/W313.7 lm/mF86.3 lm/W258.8 lm/mF69.9 lm/W209.8 lm/mG
3000 K112.3 lm/W337 lm/mE90.8 lm/W272.5 lm/mF73.9 lm/W221.6 lm/mG
3500 K114.1 lm/W342.3 lm/mE92.4 lm/W277.1 lm/mF76 lm/W228.1 lm/mG
4000 K117.7 lm/W353.2 lm/mE94.7 lm/W284 lm/mF78.1 lm/W234.3 lm/mG
5000 K117.6 lm/W352.8 lm/mE94.5 lm/W283.6 lm/mF78 lm/W234 lm/mG
6500 K107.4 lm/W322.1 lm/mF90.7 lm/W272.2 lm/mF75.3 lm/W225.9 lm/mG

Grade DL (2nd Tier) · 5.8W/m

Grade DL (2nd Tier) · 5.8W/m — measured at 5.8 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K87.9 lm/W510 lm/mF70.2 lm/W407.1 lm/mG
2300 K97.9 lm/W567.7 lm/mF78.2 lm/W453.6 lm/mG63.3 lm/W367.1 lm/mG
2700 K102.5 lm/W594.8 lm/mF84.6 lm/W490.6 lm/mG68.6 lm/W397.7 lm/mG
3000 K110.2 lm/W638.9 lm/mE89.1 lm/W516.5 lm/mF72.4 lm/W420 lm/mG
3500 K111.9 lm/W648.9 lm/mE90.6 lm/W525.3 lm/mF74.5 lm/W432.4 lm/mG
4000 K115.4 lm/W669.5 lm/mE92.8 lm/W538.3 lm/mF76.6 lm/W444.2 lm/mG
5000 K115.3 lm/W668.9 lm/mE92.7 lm/W537.7 lm/mF76.5 lm/W443.7 lm/mG
6500 K105.3 lm/W610.6 lm/mF89 lm/W515.9 lm/mF73.8 lm/W428 lm/mG

Grade DL (2nd Tier) · 8W/m

Grade DL (2nd Tier) · 8W/m — measured at 8 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K86.6 lm/W692.7 lm/mF69.1 lm/W552.9 lm/mG
2300 K96.4 lm/W771 lm/mF77 lm/W616 lm/mG62.4 lm/W499.2 lm/mG
2700 K101 lm/W807.8 lm/mF83.3 lm/W666.4 lm/mG67.5 lm/W540.1 lm/mG
3000 K108.5 lm/W867.7 lm/mF87.7 lm/W701.5 lm/mF71.3 lm/W570.5 lm/mG
3500 K110.2 lm/W881.3 lm/mE89.2 lm/W713.5 lm/mF73.4 lm/W587.3 lm/mG
4000 K113.7 lm/W909.2 lm/mE91.4 lm/W731.1 lm/mF75.4 lm/W603.2 lm/mG
5000 K113.6 lm/W908.4 lm/mE91.3 lm/W730.3 lm/mF75.3 lm/W602.4 lm/mG
6500 K103.7 lm/W829.3 lm/mF87.6 lm/W700.7 lm/mF72.7 lm/W581.6 lm/mG

Grade DN (1st Tier) · 3W/m

Grade DN (1st Tier) · 3W/m — measured at 3 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K102.2 lm/W306.6 lm/mF85.9 lm/W257.6 lm/mG
2300 K111.4 lm/W334.2 lm/mF95.8 lm/W287.4 lm/mF77.6 lm/W232.8 lm/mG
2700 K120.1 lm/W360.3 lm/mE103.6 lm/W310.9 lm/mF84 lm/W252 lm/mG
3000 K126.2 lm/W378.6 lm/mE109.4 lm/W328.3 lm/mF89 lm/W266.9 lm/mG
3500 K128.1 lm/W384.2 lm/mE111.8 lm/W335.5 lm/mF92.1 lm/W276.2 lm/mF
4000 K130.4 lm/W391.3 lm/mE112.4 lm/W337.3 lm/mF92.8 lm/W278.4 lm/mF
5000 K130.2 lm/W390.7 lm/mE113.2 lm/W339.5 lm/mF93.4 lm/W280.2 lm/mF
6500 K124.9 lm/W374.6 lm/mE108.2 lm/W324.6 lm/mF89.8 lm/W269.4 lm/mG

Grade DN (1st Tier) · 5.8W/m

Grade DN (1st Tier) · 5.8W/m — measured at 5.8 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K100.2 lm/W581.2 lm/mF84.2 lm/W488.3 lm/mG
2300 K109.2 lm/W633.6 lm/mF93.9 lm/W544.8 lm/mF76.1 lm/W441.4 lm/mG
2700 K117.8 lm/W683 lm/mF101.6 lm/W589.5 lm/mF82.4 lm/W477.7 lm/mG
3000 K123.7 lm/W717.7 lm/mE107.3 lm/W622.4 lm/mF87.2 lm/W505.9 lm/mG
3500 K125.6 lm/W728.3 lm/mE109.6 lm/W635.9 lm/mF90.3 lm/W523.6 lm/mG
4000 K127.9 lm/W741.8 lm/mE110.3 lm/W639.5 lm/mF91 lm/W527.7 lm/mG
5000 K127.7 lm/W740.7 lm/mE111 lm/W643.6 lm/mF91.5 lm/W530.7 lm/mG
6500 K122.4 lm/W710.1 lm/mE106.1 lm/W615.3 lm/mF88.1 lm/W511 lm/mG

Grade DN (1st Tier) · 8W/m

Grade DN (1st Tier) · 8W/m — measured at 8 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K98.7 lm/W789.4 lm/mF82.9 lm/W663.2 lm/mG
2300 K107.6 lm/W860.5 lm/mF92.5 lm/W739.9 lm/mF74.9 lm/W599.2 lm/mG
2700 K116 lm/W927.6 lm/mF100.1 lm/W800.6 lm/mF81.1 lm/W648.8 lm/mG
3000 K121.8 lm/W974.8 lm/mE105.7 lm/W845.3 lm/mF85.9 lm/W687.1 lm/mG
3500 K123.6 lm/W989.1 lm/mE108 lm/W863.7 lm/mF88.9 lm/W711.1 lm/mG
4000 K125.9 lm/W1007.5 lm/mE108.6 lm/W868.5 lm/mF89.6 lm/W716.7 lm/mG
5000 K125.7 lm/W1005.9 lm/mE109.3 lm/W874.1 lm/mF90.1 lm/W720.8 lm/mG
6500 K120.5 lm/W964.4 lm/mE104.5 lm/W835.7 lm/mF86.7 lm/W693.6 lm/mG

Grade KE (3rd Tier) · 3W/m

Grade KE (3rd Tier) · 3W/m — measured at 3 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K69.1 lm/W207.3 lm/mG54.8 lm/W164.5 lm/mG
2300 K77 lm/W230.9 lm/mG61.1 lm/W183.4 lm/mG49.5 lm/W148.5 lm/mG
2700 K83 lm/W248.9 lm/mG66.3 lm/W198.9 lm/mG53.7 lm/W161.1 lm/mG
3000 K87.1 lm/W261.3 lm/mF70.1 lm/W210.4 lm/mG57 lm/W171 lm/mG
3500 K88.4 lm/W265.3 lm/mF71.5 lm/W214.4 lm/mG58.9 lm/W176.6 lm/mG
4000 K91 lm/W273.1 lm/mF73 lm/W219.1 lm/mG60.3 lm/W180.9 lm/mG
5000 K90.9 lm/W272.8 lm/mF73 lm/W219.1 lm/mG60.3 lm/W180.9 lm/mG
6500 K87.1 lm/W261.3 lm/mF70.1 lm/W210.4 lm/mG58.2 lm/W174.6 lm/mG

Grade KE (3rd Tier) · 5.8W/m

Grade KE (3rd Tier) · 5.8W/m — measured at 5.8 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K67.8 lm/W393 lm/mG53.8 lm/W311.8 lm/mG
2300 K75.5 lm/W437.7 lm/mG59.9 lm/W347.7 lm/mG48.6 lm/W281.9 lm/mG
2700 K81.3 lm/W471.8 lm/mG65 lm/W377.1 lm/mG52.6 lm/W305.3 lm/mG
3000 K85.4 lm/W495.3 lm/mF68.8 lm/W398.9 lm/mG55.9 lm/W324.1 lm/mG
3500 K86.7 lm/W503 lm/mF70.1 lm/W406.5 lm/mG57.7 lm/W334.7 lm/mG
4000 K89.3 lm/W517.7 lm/mF71.6 lm/W415.3 lm/mG59.1 lm/W343 lm/mG
5000 K89.2 lm/W517.1 lm/mF71.6 lm/W415.3 lm/mG59.1 lm/W342.8 lm/mG
6500 K85.4 lm/W495.3 lm/mF68.8 lm/W398.9 lm/mG57.1 lm/W331.2 lm/mG

Grade KE (3rd Tier) · 8W/m

Grade KE (3rd Tier) · 8W/m — measured at 8 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K66.7 lm/W533.7 lm/mG52.9 lm/W423.5 lm/mG
2300 K74.3 lm/W594.4 lm/mG59 lm/W472.2 lm/mG47.8 lm/W382.4 lm/mG
2700 K80.1 lm/W640.8 lm/mG64 lm/W512.1 lm/mG51.8 lm/W414.7 lm/mG
3000 K84.1 lm/W672.7 lm/mG67.7 lm/W541.7 lm/mG55 lm/W440.2 lm/mG
3500 K85.4 lm/W683.1 lm/mF69 lm/W552.1 lm/mG56.8 lm/W454.6 lm/mG
4000 K87.9 lm/W703.1 lm/mF70.5 lm/W564.1 lm/mG58.2 lm/W465.8 lm/mG
5000 K87.8 lm/W702.3 lm/mF70.5 lm/W564.1 lm/mG58.2 lm/W465.6 lm/mG
6500 K84.1 lm/W672.7 lm/mG67.7 lm/W541.7 lm/mG56.2 lm/W449.6 lm/mG

Frequently Asked Questions

What are the key specifications of 20441?

20441: 2835, 120, DC 24V, 5mm PCB, 3oz copper FPCB, cuttable 5LEDs/41.667. Full photometric data, wiring diagrams and test reports are available in the downloads section of this page.

How long can a single run of this ultra long run LED strip be?

Maximum single run for this model is 15m. Feeding from both ends or using a mid-point tap halves the effective distance per segment, so a ultra long run LED strip can cover twice that length on one circuit when wired accordingly.

Can DENO customise this ultra long run LED strip for a project?

Yes. DENO manufactures the Ultra-Long SMD Strips series as an OEM and ODM supplier: reel length, colour temperature, CRI grade, PCB width, waterproofing and private labelling can all be specified. Request a quote for lead time and project pricing.

Does a constant current LED strip really eliminate voltage drop?

Voltage still drops along the copper, but the per-segment constant current IC holds LED current fixed until the local voltage falls below its dropout point. Brightness therefore stays even end to end, and power can be injected at one end, both ends or any mid point of the run.

What limits how long an LED strip run can be?

Voltage drop and conductor current, not the LED itself. A long run LED strip combines low watts per metre, 2 oz or thicker copper and a higher bus voltage such as 24V, 36V or 48V to reach 20 m or more from one feed while staying inside a 3 percent drop.

Constant Current LED Strip — Buyer Questions

What is a constant current LED strip?

A constant current LED strip carries a linear CC driver IC on the board that holds a fixed current through each segment regardless of the input voltage seen at that point. Brightness therefore stays flat along the run, instead of falling off with voltage drop the way a plain constant-voltage strip does.

Constant current vs constant voltage LED strip — which is better?

Constant voltage is cheaper and fine for short runs under 3 m. Constant current is the right choice whenever the run is long, the copper is thin, the input voltage is unstable, or the installation is camera-facing — the IC absorbs supply variation and keeps every metre at the same luminous flux.

Long LED Strip Lights — Buyer Questions

How long can a long LED strip run be on a single power feed?

A standard 24V constant-voltage tape is limited to about 5 m before the far end visibly dims. DENO's long-run boards combine 2 oz to 3 oz copper, 24V or 48V input and per-segment constant-current ICs, which takes a single feed to 20 m, and up to 50 m on 48V builds, with no measurable fall-off between the first and last metre.

What are the longest LED light strips DENO manufactures?

Standard reels ship at 5 m, 10 m, 15 m, 20 m and 30 m, and OEM orders are produced as one continuous 50 m board with no mid-reel solder joint. Roll-to-roll plating is what makes that possible: the copper is deposited continuously, so length is not capped by panel size the way it is on die-cut FPCB.

Why do long strip lights get dimmer at the far end, and how is it fixed?

Copper resistance drops the supply voltage along the tape, so LEDs near the end of the run receive less drive current. Three fixes work together: raise the voltage (24V, 36V or 48V), raise the copper weight (2 oz or 3 oz), and add a linear constant-current IC per segment so each segment holds its current regardless of the local voltage it sees.