2-Wire Switch-Controlled Tunable White LED Strip (#5214)
No Controller, Remote or App Needed · Wall-Switch CCT on 2-Wire 24V · 2700K / 6500K / 4000K · 12mm
- No Controller · No Remote · No App
- 2-Wire 24V Retrofit
- 2700K · 6500K · 4000K
Model: 5214

Overview
DENO #5214 is a 2-wire switch-controlled tunable white LED strip in the Special SMD Strips series. An ordinary wall switch cycles 2700K, 6500K and 4000K on a single 24V constant voltage pair, with no CCT controller, remote or app, and an on-board IC remembers the last white after power-off. Key specifications: 2835 LEDs, 168 LEDs/m, 12mm 3oz copper FPCB, cuttable every 83.33mm, < 3 SDCM, 5m single-feed or 10m dual-feed runs. OEM and ODM CCT sequences, widths and densities are available on request.
Description
This 2835 tunable white LED strip changes colour temperature directly through a standard wall switch, with no external CCT controller, RF remote or mobile app. 2-wire retrofit friendly: runs on a single 24V constant voltage pair (V+ and V−), so it can replace an existing single-colour strip in walls and ceilings without pulling new 3-conductor cabling. 3-CCT wall switch cycling: each off/on toggle steps the strip from 2700K warm white to 6500K cool white to 4000K neutral white, giving occupants of homes, hotels and offices foolproof control with no remote to lose. Power-off memory: an on-board logic IC stores the last selected colour temperature and restores it at the next power-on, so routine daily switching does not reset the chosen white. Engineered on a 12mm wide 3oz copper FPCB with 168 LEDs/m, cuttable every 14 LEDs (83.33mm); single-bin 2835 LEDs hold < 3 SDCM colour consistency over a 5m single-feed run (10m with dual input power). Factory-direct OEM/ODM: custom CCT sequences, widths and densities with switch-controlled colour change are engineered on request, backed by a 5-year warranty.
We use 99.99% gold wire, large-size chips, and thickened FPCB, backed by a 5-year warranty.
One wall switch, three colour temperatures
Each quick off–on toggle moves to the next mode: 2700K warm white, 6500K cool white, then 4000K neutral white (both channels on). The strip remembers the last mode after power-off, and a dimmer can be added on the same two-wire circuit.
Dual Control on 2 Wires: CCT + Dimming
Add an ordinary single-channel 24V dimmer and the same circuit does both jobs: toggle its on/off switch to step through 2700K → 6500K → 4000K, then turn or slide the dimmer to set the brightness of the selected colour temperature.
Full dimming compatibility: works with a standard single-channel 24V dimmer. Toggle the power to change CCT (2700K → 6500K → 4000K) and use the dimmer to adjust brightness at the chosen colour temperature.
Standard 24V power supply, two output wires, no controller
DENO bench footage: the mains plug is toggled; the strip is fed only by V+ and V− from an ordinary constant-voltage supply.
Retrofit wiring
- Conventional tunable white: 3 conductors (V+, WW−, CW−), two-channel CCT controller, remote or app, new cable runs.
- DENO #5214: 2 conductors (V+, V−), any standard 24V constant-voltage supply, ordinary wall switch, reuses the existing two-wire circuit.
How a standard wall switch changes the colour temperature
Need a similar version? Need another CCT sequence, width or density with switch-controlled colour change? Send your drawing or target specification and our engineers will confirm feasibility.
Specifications
| SDCM | < 3 SDCM (Single Bin) |
|---|---|
| LED QTY | 168 |
| PART NO | DL-F28A84V24-5214-* |
| SMD TYPE | 2835 |
| CUTTABLE UNIT | 14LEDs/83.33mm |
| DIMMABLE | Yes |
| IP RATING | IP20 |
| LED PITCH | 11.9mm |
| PCB WIDTH | 12mm |
| WARRANTY | 5 Years |
| BEAM ANGLE | 120° |
| RUN LENGTH | 5m |
| COPPER FOIL | 3oz |
| POWER RANGE | 12~35W |
| CIRCUIT TYPE | C.V. |
| INPUT VOLTAGE | 24V |
| OPERATING TEMPERATURE | -25~40°C;Tc:75°C(max) |
Applications
- Cove, wall-wash & perimeter lighting — Coves, recesses, wall-wash details and ceiling perimeters where a continuous, uniform line of light is required.
- Showroom & hospitality display lighting — Shelving, display cases, reception desks and signage backlighting in shops, showrooms and hospitality spaces.
- Kitchen & wardrobe under-cabinet lighting — Kitchen, wardrobe and furniture task lighting where the strip stays hidden and only the light is seen.
- Hotel & residential tunable-white scenes — Hotel rooms, residential living areas and meeting spaces where warm evening light and neutral daytime light are both required from one fixture.
Recommended accessories & compatible parts
- DL-1201 — 25x14.5mm Wide Surface Mount LED Channel — Aluminum Profile for 12mm Strip: Accepts LED strips up to 12mm wide.
- DL-1202 — 17.3x14.5mm Surface Mount LED Channel — Deep Aluminum Profile for 12mm Strip: Accepts LED strips up to 12mm wide.
- DL-1204 — 25x7mm Wide Slim Surface Mount LED Channel — Dotless Aluminum Profile for 240 LEDs/m: Accepts LED strips up to 12mm wide.
- DN-PSU-100 — 24V 100W Class-2 LED Driver · High Efficiency: Matches the 24V DC input of this strip; size the driver with at least 20% headroom over total load.
- DN-PSU-150 — 24V 150W Class-2 LED Driver · Premium: Matches the 24V DC input of this strip; size the driver with at least 20% headroom over total load.
- DN-PSU-60 — 24V 60W Class-2 LED Driver · Constant Voltage: Matches the 24V DC input of this strip; size the driver with at least 20% headroom over total load.
- V2 — 12-24VDC 2-Channel * 5A Color Temperature Controller | V2: Matched by input voltage range and colour channels.
Request a quotation for #5214
DENO LED is a Shenzhen-based LED strip manufacturer with its own Foshan production base. Send the run length, voltage, CCT/CRI and IP rating you need and our engineering team replies with a specification sheet, wiring plan and price — OEM/ODM and fully custom builds included.
- Warranty: 5 years
- Lead time: custom samples 3–5 working days · new FPCB: 1–3 weeks · production 1–2 weeks after sample approval
- Compliance: CE · UL · RoHS
- Bonding wire: 99.99% pure gold
- Copper foil: 99.9% pure copper FPCB
Photometric Performance — CCT × CRI Efficacy Matrix
Peak measured luminous efficacy: 180.9 lm/W at 6500K, Ra 80, ErP energy class C (Grade DN (1st Tier) · CCT 3-Anchor · 12W/m).
All values are measured at the stated power density and ambient 25 °C, reported as luminous efficacy in lumens per watt (lm/W), luminous flux per metre (lm/m) and the corresponding EU ErP (2019/2015) energy class.
Grade DN (1st Tier) · CCT 3-Anchor · 12W/m
| CCT (K) | Ra 80 — Luminous Efficacy (lm/W) | Ra 80 — Luminous Flux (lm/m) | Ra 80 — ErP Energy Class | Ra 90 — Luminous Efficacy (lm/W) | Ra 90 — Luminous Flux (lm/m) | Ra 90 — ErP Energy Class | Full Spectrum (Ra 95+) — Luminous Efficacy (lm/W) | Full Spectrum (Ra 95+) — Luminous Flux (lm/m) | Full Spectrum (Ra 95+) — ErP Energy Class |
|---|---|---|---|---|---|---|---|---|---|
| 2700 K | 163.1 lm/W | 978.3 lm/m | D | 132.4 lm/W | 794.6 lm/m | E | 103.3 lm/W | 619.8 lm/m | F |
| 4000 K | 164.6 lm/W | 1975.6 lm/m | D | 133.8 lm/W | 1605.7 lm/m | E | 104.4 lm/W | 1252.2 lm/m | F |
| 6500 K | 180.9 lm/W | 1085.6 lm/m | C | 147.2 lm/W | 883 lm/m | D | 114.8 lm/W | 688.6 lm/m | F |
Grade DN (1st Tier) · CCT 3-Anchor · 14.4W/m
| CCT (K) | Ra 80 — Luminous Efficacy (lm/W) | Ra 80 — Luminous Flux (lm/m) | Ra 80 — ErP Energy Class | Ra 90 — Luminous Efficacy (lm/W) | Ra 90 — Luminous Flux (lm/m) | Ra 90 — ErP Energy Class | Full Spectrum (Ra 95+) — Luminous Efficacy (lm/W) | Full Spectrum (Ra 95+) — Luminous Flux (lm/m) | Full Spectrum (Ra 95+) — ErP Energy Class |
|---|---|---|---|---|---|---|---|---|---|
| 2700 K | 160.3 lm/W | 1154.4 lm/m | D | 130.2 lm/W | 937.6 lm/m | E | 101.6 lm/W | 731.3 lm/m | F |
| 4000 K | 161.9 lm/W | 2331 lm/m | D | 131.6 lm/W | 1894.6 lm/m | E | 102.6 lm/W | 1477.6 lm/m | F |
| 6500 K | 177.9 lm/W | 1281 lm/m | C | 144.7 lm/W | 1041.9 lm/m | E | 112.8 lm/W | 812.5 lm/m | F |
Grade DN (1st Tier) · CCT 3-Anchor · 19.2W/m
| CCT (K) | Ra 80 — Luminous Efficacy (lm/W) | Ra 80 — Luminous Flux (lm/m) | Ra 80 — ErP Energy Class | Ra 90 — Luminous Efficacy (lm/W) | Ra 90 — Luminous Flux (lm/m) | Ra 90 — ErP Energy Class | Full Spectrum (Ra 95+) — Luminous Efficacy (lm/W) | Full Spectrum (Ra 95+) — Luminous Flux (lm/m) | Full Spectrum (Ra 95+) — ErP Energy Class |
|---|---|---|---|---|---|---|---|---|---|
| 2700 K | 155 lm/W | 1488.1 lm/m | D | 125.9 lm/W | 1208.7 lm/m | E | 98.2 lm/W | 942.8 lm/m | F |
| 4000 K | 156.5 lm/W | 3005 lm/m | D | 127.2 lm/W | 2442.4 lm/m | E | 99.2 lm/W | 1904.8 lm/m | F |
| 6500 K | 172 lm/W | 1651.3 lm/m | D | 139.9 lm/W | 1343.1 lm/m | E | 109.1 lm/W | 1047.4 lm/m | F |
Grade DN (1st Tier) · CCT 3-Anchor · 22W/m
| CCT (K) | Ra 80 — Luminous Efficacy (lm/W) | Ra 80 — Luminous Flux (lm/m) | Ra 80 — ErP Energy Class | Ra 90 — Luminous Efficacy (lm/W) | Ra 90 — Luminous Flux (lm/m) | Ra 90 — ErP Energy Class | Full Spectrum (Ra 95+) — Luminous Efficacy (lm/W) | Full Spectrum (Ra 95+) — Luminous Flux (lm/m) | Full Spectrum (Ra 95+) — ErP Energy Class |
|---|---|---|---|---|---|---|---|---|---|
| 2700 K | 152 lm/W | 1671.9 lm/m | D | 123.5 lm/W | 1358 lm/m | E | 96.3 lm/W | 1059.2 lm/m | F |
| 4000 K | 153.5 lm/W | 3376.2 lm/m | D | 124.7 lm/W | 2744.1 lm/m | E | 97.3 lm/W | 2140 lm/m | F |
| 6500 K | 168.7 lm/W | 1855.3 lm/m | D | 137.2 lm/W | 1509 lm/m | E | 107 lm/W | 1176.8 lm/m | F |
Grade DL (2nd Tier) · CCT 3-Anchor · 12W/m
| CCT (K) | Ra 80 — Luminous Efficacy (lm/W) | Ra 80 — Luminous Flux (lm/m) | Ra 80 — ErP Energy Class | Ra 90 — Luminous Efficacy (lm/W) | Ra 90 — Luminous Flux (lm/m) | Ra 90 — ErP Energy Class | Full Spectrum (Ra 95+) — Luminous Efficacy (lm/W) | Full Spectrum (Ra 95+) — Luminous Flux (lm/m) | Full Spectrum (Ra 95+) — ErP Energy Class |
|---|---|---|---|---|---|---|---|---|---|
| 2700 K | 140.1 lm/W | 840.7 lm/m | D | 113.7 lm/W | 682.3 lm/m | E | 88.7 lm/W | 532.1 lm/m | F |
| 4000 K | 141.6 lm/W | 1699.1 lm/m | D | 114.9 lm/W | 1378.5 lm/m | E | 89.6 lm/W | 1075.5 lm/m | F |
| 6500 K | 155.6 lm/W | 933.5 lm/m | D | 126.3 lm/W | 758 lm/m | E | 98.6 lm/W | 591.4 lm/m | F |
Grade DL (2nd Tier) · CCT 3-Anchor · 14.4W/m
| CCT (K) | Ra 80 — Luminous Efficacy (lm/W) | Ra 80 — Luminous Flux (lm/m) | Ra 80 — ErP Energy Class | Ra 90 — Luminous Efficacy (lm/W) | Ra 90 — Luminous Flux (lm/m) | Ra 90 — ErP Energy Class | Full Spectrum (Ra 95+) — Luminous Efficacy (lm/W) | Full Spectrum (Ra 95+) — Luminous Flux (lm/m) | Full Spectrum (Ra 95+) — ErP Energy Class |
|---|---|---|---|---|---|---|---|---|---|
| 2700 K | 137.8 lm/W | 992 lm/m | D | 111.8 lm/W | 805.1 lm/m | E | 87.2 lm/W | 627.8 lm/m | F |
| 4000 K | 139.2 lm/W | 2004.8 lm/m | D | 113 lm/W | 1626.5 lm/m | E | 88.1 lm/W | 1269 lm/m | F |
| 6500 K | 153 lm/W | 1101.5 lm/m | D | 124.2 lm/W | 894.4 lm/m | E | 96.9 lm/W | 697.8 lm/m | F |
Grade DL (2nd Tier) · CCT 3-Anchor · 19.2W/m
| CCT (K) | Ra 80 — Luminous Efficacy (lm/W) | Ra 80 — Luminous Flux (lm/m) | Ra 80 — ErP Energy Class | Ra 90 — Luminous Efficacy (lm/W) | Ra 90 — Luminous Flux (lm/m) | Ra 90 — ErP Energy Class | Full Spectrum (Ra 95+) — Luminous Efficacy (lm/W) | Full Spectrum (Ra 95+) — Luminous Flux (lm/m) | Full Spectrum (Ra 95+) — ErP Energy Class |
|---|---|---|---|---|---|---|---|---|---|
| 2700 K | 133.2 lm/W | 1278.8 lm/m | E | 108.1 lm/W | 1037.8 lm/m | F | 84.3 lm/W | 809.3 lm/m | G |
| 4000 K | 134.6 lm/W | 2584.5 lm/m | E | 109.2 lm/W | 2096.8 lm/m | F | 85.2 lm/W | 1636 lm/m | F |
| 6500 K | 147.9 lm/W | 1419.9 lm/m | D | 120.1 lm/W | 1153 lm/m | E | 93.7 lm/W | 899.6 lm/m | F |
Grade DL (2nd Tier) · CCT 3-Anchor · 22W/m
| CCT (K) | Ra 80 — Luminous Efficacy (lm/W) | Ra 80 — Luminous Flux (lm/m) | Ra 80 — ErP Energy Class | Ra 90 — Luminous Efficacy (lm/W) | Ra 90 — Luminous Flux (lm/m) | Ra 90 — ErP Energy Class | Full Spectrum (Ra 95+) — Luminous Efficacy (lm/W) | Full Spectrum (Ra 95+) — Luminous Flux (lm/m) | Full Spectrum (Ra 95+) — ErP Energy Class |
|---|---|---|---|---|---|---|---|---|---|
| 2700 K | 130.6 lm/W | 1436.8 lm/m | E | 106 lm/W | 1166 lm/m | F | 82.7 lm/W | 909.3 lm/m | G |
| 4000 K | 132 lm/W | 2903.7 lm/m | E | 107.1 lm/W | 2355.8 lm/m | F | 83.5 lm/W | 1838 lm/m | G |
| 6500 K | 145 lm/W | 1595.3 lm/m | D | 117.8 lm/W | 1295.5 lm/m | E | 91.9 lm/W | 1010.7 lm/m | F |
Grade KE (3rd Tier) · CCT 3-Anchor · 12W/m
| CCT (K) | Ra 80 — Luminous Efficacy (lm/W) | Ra 80 — Luminous Flux (lm/m) | Ra 80 — ErP Energy Class | Ra 90 — Luminous Efficacy (lm/W) | Ra 90 — Luminous Flux (lm/m) | Ra 90 — ErP Energy Class | Full Spectrum (Ra 95+) — Luminous Efficacy (lm/W) | Full Spectrum (Ra 95+) — Luminous Flux (lm/m) | Full Spectrum (Ra 95+) — ErP Energy Class |
|---|---|---|---|---|---|---|---|---|---|
| 2700 K | 114.8 lm/W | 688.6 lm/m | E | 92.9 lm/W | 557.3 lm/m | F | 72.5 lm/W | 434.9 lm/m | G |
| 4000 K | 115.9 lm/W | 1391.1 lm/m | E | 93.8 lm/W | 1126 lm/m | F | 73.2 lm/W | 878.6 lm/m | G |
| 6500 K | 127.4 lm/W | 764.3 lm/m | E | 103.2 lm/W | 619.2 lm/m | F | 80.5 lm/W | 482.8 lm/m | G |
Grade KE (3rd Tier) · CCT 3-Anchor · 14.4W/m
| CCT (K) | Ra 80 — Luminous Efficacy (lm/W) | Ra 80 — Luminous Flux (lm/m) | Ra 80 — ErP Energy Class | Ra 90 — Luminous Efficacy (lm/W) | Ra 90 — Luminous Flux (lm/m) | Ra 90 — ErP Energy Class | Full Spectrum (Ra 95+) — Luminous Efficacy (lm/W) | Full Spectrum (Ra 95+) — Luminous Flux (lm/m) | Full Spectrum (Ra 95+) — ErP Energy Class |
|---|---|---|---|---|---|---|---|---|---|
| 2700 K | 112.8 lm/W | 812.5 lm/m | E | 91.3 lm/W | 657.6 lm/m | F | 71.3 lm/W | 513.1 lm/m | G |
| 4000 K | 114 lm/W | 1641.4 lm/m | E | 92.3 lm/W | 1328.6 lm/m | F | 72 lm/W | 1036.7 lm/m | G |
| 6500 K | 125.3 lm/W | 901.9 lm/m | E | 101.5 lm/W | 730.6 lm/m | F | 79.1 lm/W | 569.7 lm/m | G |
Grade KE (3rd Tier) · CCT 3-Anchor · 19.2W/m
| CCT (K) | Ra 80 — Luminous Efficacy (lm/W) | Ra 80 — Luminous Flux (lm/m) | Ra 80 — ErP Energy Class | Ra 90 — Luminous Efficacy (lm/W) | Ra 90 — Luminous Flux (lm/m) | Ra 90 — ErP Energy Class | Full Spectrum (Ra 95+) — Luminous Efficacy (lm/W) | Full Spectrum (Ra 95+) — Luminous Flux (lm/m) | Full Spectrum (Ra 95+) — ErP Energy Class |
|---|---|---|---|---|---|---|---|---|---|
| 2700 K | 109.1 lm/W | 1047.4 lm/m | F | 88.3 lm/W | 847.7 lm/m | F | 68.9 lm/W | 661.5 lm/m | G |
| 4000 K | 110.2 lm/W | 2116 lm/m | E | 89.2 lm/W | 1712.8 lm/m | F | 69.6 lm/W | 1336.4 lm/m | G |
| 6500 K | 121.1 lm/W | 1162.6 lm/m | E | 98.1 lm/W | 941.8 lm/m | F | 76.5 lm/W | 734.5 lm/m | G |
Grade KE (3rd Tier) · CCT 3-Anchor · 22W/m
| CCT (K) | Ra 80 — Luminous Efficacy (lm/W) | Ra 80 — Luminous Flux (lm/m) | Ra 80 — ErP Energy Class | Ra 90 — Luminous Efficacy (lm/W) | Ra 90 — Luminous Flux (lm/m) | Ra 90 — ErP Energy Class | Full Spectrum (Ra 95+) — Luminous Efficacy (lm/W) | Full Spectrum (Ra 95+) — Luminous Flux (lm/m) | Full Spectrum (Ra 95+) — ErP Energy Class |
|---|---|---|---|---|---|---|---|---|---|
| 2700 K | 107 lm/W | 1176.8 lm/m | F | 86.6 lm/W | 952.4 lm/m | F | 67.6 lm/W | 743.2 lm/m | G |
| 4000 K | 108.1 lm/W | 2377.3 lm/m | F | 87.5 lm/W | 1924.3 lm/m | F | 68.2 lm/W | 1501.5 lm/m | G |
| 6500 K | 118.7 lm/W | 1306.2 lm/m | E | 96.2 lm/W | 1058.2 lm/m | F | 75 lm/W | 825.2 lm/m | G |
High-Power LED Strip: Heat Dissipation & Aluminum Channel Guide
At up to 22W/m, 5214 is a high-power SMD LED strip. Above roughly 14.4W/m the tape can no longer shed its own heat through the FPC alone — an aluminum channel is part of the luminaire, not an accessory.
Why high-wattage strips need a heat sink
- Aluminum conducts heat roughly 30× faster than the plastics, MDF or gypsum a strip is usually stuck to, so a bare high-power run traps heat under the tape.
- LED lifetime (LM-80 / TM-21) is driven by solder-point temperature Tc. Keeping Tc inside the datasheet limit — DENO strips are rated Tc ≤ 75°C — is what preserves the rated L70 lifetime and colour stability.
- Never run 14.4W/m or more coiled on the reel, inside a sealed plastic diffuser, or directly on wood, wallpaper or foam.
Sizing rule: FPC width vs channel inner width
- Channel inner width ≥ FPC width + 2mm. This strip is 12mm wide, so it needs at least 14mm of inner width.
- The 2mm clearance absorbs extrusion tolerance and lets the tape be seated or replaced without scraping the side walls or the wiring.
- A frosted or opal PC cover then diffuses the higher lumen output into an even, dot-free line instead of visible hot spots.
Aluminum channels that fit this strip
- 20x08mm Surface Mount LED Channel · fits ≤12mm strip
- 18x18mm Magnetic LED Channel · fits ≤12mm strip
- 17.3x14.5mm Surface Mount LED Channel · fits ≤12mm strip
- 17.5x7mm Slim Surface Mount LED Channel · fits ≤12mm strip
- Slim Surface Aluminum Profile · 12mm PCB · fits ≤12mm strip
- 25x7mm Wide Slim Surface Mount LED Channel · fits ≤12mm strip
Recommended LED Channels
Mount this LED strip in a DENO LED aluminum profile for heat dissipation, physical protection and diffused, dot-free output.
This strip is 12mm wide, so it needs a channel with at least 14mm inner width (12mm + 2mm clearance). Every profile below meets that.
Frequently Asked Questions
Can I get tunable white lighting without installing any controller?
Yes. Choose DENO's switch-controlled tunable white LED strip (#5214). An ordinary wall switch changes the colour temperature: each off-on toggle steps through 2700K warm white, 6500K cool white and 4000K neutral white on a standard two-wire 24V circuit, with no CCT controller, remote or app.
How does the #5214 change colour temperature without a controller?
Switching the power off and on again with a standard wall switch steps the strip to the next white in its sequence: 2700K, then 6500K, then 4000K. No remote, app or CCT controller is needed.
How does the strip switch CCT without a signal wire?
An on-board logic IC on the FPCB detects the power toggle from the wall switch and moves the LEDs to the next channel combination, so no data or control conductor is needed.
Can I upgrade an existing single-colour 24V strip to tunable white without replacing the two wires?
Yes. The #5214 runs on a single V+/V- pair from a standard 24V constant voltage supply, so it can replace a single-colour strip where only two conductors are installed, without new cable runs.
Does the #5214 remember the last colour temperature after a power cut?
Yes. The strip stores the last selected white and returns to it the next time power is applied, so a room keeps its preferred colour temperature after a switch-off or power interruption.