DENO LED Lighting

2835 Classic LED Strip Light (#2300)

8mm · 12V · 60LEDs · 50mm/cut

Model: 2300

2300 2835 Classic LED Strip Light | 8mm | 12V | 60LEDs | 50mm/cut | #2300 — 12V, cuttable every 50mm, 8mm FPCB width, 2835 LEDs, 60 LEDs/m

Overview

2835 Classic LED Strip Light | 8mm | 12V | 60LEDs | 50mm/cut | #2300 is part of the DENO Classic SMD Strips series, engineered around 24V SMD LED strip lights. Key specifications: 2835, 60 LEDs/m, DC 12V, 8mm PCB, 3oz copper FPCB, cuttable 3LEDs/50mm. Every reel is produced on DENO's roll-to-roll line with 99.9% pure copper FPCB and ships CE, UL and RoHS compliant for architectural, retail and hospitality projects. OEM and ODM configurations of length, colour temperature and waterproofing are available on request.

Description

2835 Classic LED Strip Light | 8mm | 12V | 60LEDs | 50mm/cut | #2300 Strong pure copper LED frame, and diameter>1mm, 99.9%-purity gold wire encapsulation, can reduce damage to the LED in different applications. High brightness SMD2835 LED Strips is outfitted with extremely bright LED chips and strong adhesive backing. Special heat resistant PCB layout, copper layer 3Oz that make sure lower voltage drop and excellent heat dissipation. 3 SDCM 1 BIN , these strips are great for providing elegant and discreet lighting.

24v Smd Led Strip Lights built for classic smd strips projects.

Specifications

LED QTY60 LEDs/m
PART NODL-F28A30V12-2300-*
SMD TYPE2835
CUTTABLE UNIT3LEDs/50mm
DIMMABLEYes
LED PITCH16.6mm
PCB WIDTH8mm
BEAM ANGLE120°
LENGTH MAX5m
COPPER FOIL3oz
POWER RANGE2.4~14.4W
CIRCUIT TYPEC.V.
INPUT VOLTAGEDC 12V

Applications

  • Cove, wall-wash & perimeter lighting — Coves, recesses, wall-wash details and ceiling perimeters where a continuous, uniform line of light is required.
  • Showroom & hospitality display lighting — Shelving, display cases, reception desks and signage backlighting in shops, showrooms and hospitality spaces.
  • Kitchen & wardrobe under-cabinet lighting — Kitchen, wardrobe and furniture task lighting where the strip stays hidden and only the light is seen.

Request a quotation for #2300

DENO LED is a Shenzhen-based LED strip manufacturer with its own Foshan production base. Send the run length, voltage, CCT/CRI and IP rating you need and our engineering team replies with a specification sheet, wiring plan and price — OEM/ODM and fully custom builds included.

  • Warranty: 5 years
  • Compliance: CE · UL · RoHS
  • Bonding wire: 99.99% pure gold
  • Copper foil: 99.9% pure copper FPCB

Contact DENO LED engineers · OEM / ODM capability

Photometric Performance — CCT × CRI Efficacy Matrix

Peak measured luminous efficacy: 171 lm/W at 4000K, Ra 80, ErP energy class D (Grade DN (1st Tier)).

All values are measured at the stated power density and ambient 25 °C, reported as luminous efficacy in lumens per watt (lm/W), luminous flux per metre (lm/m) and the corresponding EU ErP (2019/2015) energy class.

Grade DL (2nd Tier)

Grade DL (2nd Tier) — measured at 6 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K123.9 lm/W743.6 lm/mE99.3 lm/W596 lm/mF
2300 K137.9 lm/W827.6 lm/mD110.6 lm/W663.8 lm/mE89.6 lm/W537.6 lm/mF
2700 K145.6 lm/W873.8 lm/mD119.7 lm/W718.4 lm/mE97 lm/W582.2 lm/mF
3000 K155.2 lm/W931.4 lm/mD125.9 lm/W755.6 lm/mE102.4 lm/W614.6 lm/mF
3500 K157.6 lm/W945.9 lm/mD128.2 lm/W769.4 lm/mE105.5 lm/W633.2 lm/mF
4000 K162.6 lm/W975.9 lm/mC131.3 lm/W788 lm/mE108.4 lm/W650.6 lm/mF
5000 K162.4 lm/W974.7 lm/mC131.2 lm/W787.4 lm/mE108.3 lm/W649.8 lm/mF
6500 K148.8 lm/W893 lm/mD125.9 lm/W755.6 lm/mE104.5 lm/W627 lm/mF

Grade DL (2nd Tier)

Grade DL (2nd Tier) — measured at 7.2 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K122.9 lm/W884.8 lm/mE98.5 lm/W709.1 lm/mF
2300 K136.8 lm/W984.8 lm/mD109.7 lm/W789.8 lm/mF88.9 lm/W640.1 lm/mF
2700 K144.4 lm/W1039.8 lm/mD118.7 lm/W854.8 lm/mE96.2 lm/W692.7 lm/mF
3000 K153.9 lm/W1108.4 lm/mD124.9 lm/W899.1 lm/mE101.6 lm/W731.3 lm/mF
3500 K156.3 lm/W1125.5 lm/mD127.2 lm/W915.5 lm/mE104.6 lm/W753.4 lm/mF
4000 K161.3 lm/W1161.2 lm/mC130.2 lm/W937.7 lm/mE107.5 lm/W774.1 lm/mF
5000 K161.1 lm/W1159.8 lm/mC130.1 lm/W937 lm/mE107.4 lm/W773.3 lm/mF
6500 K147.6 lm/W1062.7 lm/mD124.9 lm/W899.1 lm/mE103.6 lm/W745.9 lm/mF

Grade DL (2nd Tier)

Grade DL (2nd Tier) — measured at 9.6 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K120.8 lm/W1160 lm/mE96.8 lm/W929.7 lm/mF
2300 K134.5 lm/W1291.1 lm/mE107.9 lm/W1035.5 lm/mF87.4 lm/W839 lm/mF
2700 K142 lm/W1363.2 lm/mD116.7 lm/W1120.7 lm/mE94.6 lm/W908.2 lm/mF
3000 K151.4 lm/W1453.1 lm/mD122.8 lm/W1178.8 lm/mE99.9 lm/W958.7 lm/mF
3500 K153.7 lm/W1475.6 lm/mD125 lm/W1200.3 lm/mE102.9 lm/W987.8 lm/mF
4000 K158.6 lm/W1522.4 lm/mD128.1 lm/W1229.3 lm/mE105.7 lm/W1014.9 lm/mF
5000 K158.4 lm/W1520.5 lm/mD128 lm/W1228.4 lm/mE105.6 lm/W1013.8 lm/mF
6500 K145.1 lm/W1393.2 lm/mD122.8 lm/W1178.8 lm/mE101.9 lm/W978.2 lm/mF

Grade DL (2nd Tier)

Grade DL (2nd Tier) — measured at 10.8 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K119.8 lm/W1294.1 lm/mE96 lm/W1037.2 lm/mF
2300 K133.4 lm/W1440.3 lm/mE107 lm/W1155.2 lm/mF86.6 lm/W935.3 lm/mF
2700 K140.8 lm/W1520.7 lm/mD115.8 lm/W1250.2 lm/mE93.8 lm/W1013.1 lm/mF
3000 K150.1 lm/W1621 lm/mD121.8 lm/W1315 lm/mE99 lm/W1069.5 lm/mF
3500 K152.4 lm/W1646.1 lm/mD124 lm/W1339 lm/mE102 lm/W1101.9 lm/mF
4000 K157.3 lm/W1698.3 lm/mD127 lm/W1371.4 lm/mE104.8 lm/W1132.2 lm/mF
5000 K157.1 lm/W1696.2 lm/mD126.9 lm/W1370.3 lm/mE104.7 lm/W1130.8 lm/mF
6500 K143.9 lm/W1554.2 lm/mD121.8 lm/W1315 lm/mE101.1 lm/W1091.9 lm/mF

Grade DL (2nd Tier)

Grade DL (2nd Tier) — measured at 12 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K118.8 lm/W1425.8 lm/mE95.2 lm/W1142.7 lm/mF
2300 K132.2 lm/W1586.9 lm/mE106.1 lm/W1272.8 lm/mF85.9 lm/W1030.8 lm/mF
2700 K139.6 lm/W1675.5 lm/mD114.8 lm/W1377.5 lm/mE93 lm/W1116.3 lm/mF
3000 K148.8 lm/W1786 lm/mD120.7 lm/W1448.8 lm/mE98.2 lm/W1178.4 lm/mF
3500 K151.1 lm/W1813.6 lm/mD122.9 lm/W1475.3 lm/mE101.2 lm/W1214.1 lm/mF
4000 K155.9 lm/W1871.2 lm/mD125.9 lm/W1511 lm/mE104 lm/W1247.4 lm/mF
5000 K155.7 lm/W1868.9 lm/mD125.8 lm/W1509.8 lm/mE103.8 lm/W1245.6 lm/mF
6500 K142.7 lm/W1712.4 lm/mD120.7 lm/W1448.8 lm/mE100.2 lm/W1202.4 lm/mF

Grade DN (1st Tier)

Grade DN (1st Tier) — measured at 6 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K134 lm/W804.2 lm/mE112.9 lm/W677.6 lm/mF
2300 K146.1 lm/W876.8 lm/mD126 lm/W756.2 lm/mE102.1 lm/W612.6 lm/mF
2700 K157.5 lm/W945.3 lm/mD136.3 lm/W818 lm/mE110.5 lm/W663.2 lm/mF
3000 K165.4 lm/W992.7 lm/mD143.9 lm/W863.6 lm/mE117 lm/W702.2 lm/mF
3500 K167.9 lm/W1007.7 lm/mD147 lm/W882.2 lm/mD121 lm/W726.2 lm/mE
4000 K171 lm/W1026.3 lm/mD147.8 lm/W887 lm/mD122 lm/W732.2 lm/mE
5000 K170.8 lm/W1025.1 lm/mD148.8 lm/W893 lm/mD122.8 lm/W736.8 lm/mE
6500 K163.7 lm/W982.5 lm/mD142.2 lm/W853.4 lm/mE118.1 lm/W708.6 lm/mF

Grade DN (1st Tier)

Grade DN (1st Tier) — measured at 7.2 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K132.9 lm/W957 lm/mE112 lm/W806.3 lm/mF
2300 K144.9 lm/W1043.4 lm/mE125 lm/W899.8 lm/mE101.2 lm/W728.6 lm/mF
2700 K156.2 lm/W1124.8 lm/mD135.2 lm/W973.4 lm/mE109.6 lm/W789.1 lm/mF
3000 K164.1 lm/W1181.2 lm/mD142.7 lm/W1027.7 lm/mE116 lm/W835.6 lm/mF
3500 K166.5 lm/W1199.1 lm/mD145.8 lm/W1049.8 lm/mD120 lm/W864.1 lm/mE
4000 K169.6 lm/W1221.2 lm/mD146.6 lm/W1055.5 lm/mD121 lm/W871.3 lm/mE
5000 K169.4 lm/W1219.8 lm/mD147.6 lm/W1062.7 lm/mD121.8 lm/W877 lm/mE
6500 K162.4 lm/W1169.1 lm/mD141 lm/W1015.5 lm/mE117.1 lm/W843.1 lm/mF

Grade DN (1st Tier)

Grade DN (1st Tier) — measured at 9.6 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K130.7 lm/W1254.6 lm/mE110.1 lm/W1057.1 lm/mF
2300 K142.5 lm/W1367.9 lm/mE122.9 lm/W1179.7 lm/mE99.5 lm/W955.2 lm/mF
2700 K153.6 lm/W1474.6 lm/mD132.9 lm/W1276.1 lm/mE107.8 lm/W1034.6 lm/mF
3000 K161.3 lm/W1548.6 lm/mD140.3 lm/W1347.3 lm/mE114.1 lm/W1095.4 lm/mF
3500 K163.8 lm/W1572 lm/mD143.4 lm/W1376.3 lm/mE118 lm/W1132.9 lm/mF
4000 K166.8 lm/W1601 lm/mD144.1 lm/W1383.8 lm/mE119 lm/W1142.3 lm/mE
5000 K166.6 lm/W1599.2 lm/mD145.1 lm/W1393.2 lm/mE119.7 lm/W1149.1 lm/mE
6500 K159.7 lm/W1532.7 lm/mD138.7 lm/W1331.4 lm/mE115.1 lm/W1105 lm/mF

Grade DN (1st Tier)

Grade DN (1st Tier) — measured at 10.8 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K129.6 lm/W1399.6 lm/mE109.2 lm/W1179.2 lm/mF
2300 K141.3 lm/W1526 lm/mE121.9 lm/W1316 lm/mE98.7 lm/W1066 lm/mF
2700 K152.3 lm/W1645 lm/mD131.8 lm/W1423.6 lm/mE106.9 lm/W1154.1 lm/mF
3000 K160 lm/W1727.6 lm/mD139.2 lm/W1503 lm/mE113.2 lm/W1222 lm/mF
3500 K162.4 lm/W1753.7 lm/mD142.2 lm/W1535.4 lm/mE117 lm/W1263.8 lm/mF
4000 K165.4 lm/W1786 lm/mD142.9 lm/W1543.7 lm/mE118 lm/W1274.3 lm/mF
5000 K165.2 lm/W1784 lm/mD143.9 lm/W1554.2 lm/mE118.7 lm/W1282 lm/mF
6500 K158.3 lm/W1709.8 lm/mD137.5 lm/W1485.2 lm/mE114.1 lm/W1232.3 lm/mF

Grade DN (1st Tier)

Grade DN (1st Tier) — measured at 12 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1800 K128.5 lm/W1542 lm/mE108.3 lm/W1299.2 lm/mF
2300 K140.1 lm/W1681.3 lm/mE120.8 lm/W1450 lm/mE97.9 lm/W1174.8 lm/mF
2700 K151 lm/W1812.5 lm/mD130.7 lm/W1568.5 lm/mE106 lm/W1271.6 lm/mF
3000 K158.6 lm/W1903.4 lm/mD138 lm/W1656 lm/mE112.2 lm/W1346.4 lm/mF
3500 K161 lm/W1932.2 lm/mD141 lm/W1691.6 lm/mE116 lm/W1392.4 lm/mF
4000 K164 lm/W1967.8 lm/mD141.7 lm/W1700.9 lm/mE117 lm/W1404 lm/mF
5000 K163.8 lm/W1965.5 lm/mD142.7 lm/W1712.4 lm/mE117.7 lm/W1412.4 lm/mF
6500 K157 lm/W1883.8 lm/mD136.4 lm/W1636.4 lm/mE113.2 lm/W1358.4 lm/mF

Grade KE (3rd Tier)

Grade KE (3rd Tier) — measured at 6 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K103.6 lm/W621.8 lm/mF82.9 lm/W497.5 lm/mG
2300 K115.5 lm/W693.2 lm/mE92.4 lm/W554.5 lm/mF74.9 lm/W449.4 lm/mG
2700 K124.5 lm/W747.2 lm/mE100.2 lm/W601.4 lm/mF81.2 lm/W487.3 lm/mG
3000 K130.7 lm/W784.4 lm/mE105.9 lm/W635.6 lm/mF86.1 lm/W516.7 lm/mF
3500 K132.7 lm/W796.4 lm/mE108 lm/W648.2 lm/mF88.9 lm/W533.5 lm/mF
4000 K136.6 lm/W819.8 lm/mD110.3 lm/W662 lm/mE91 lm/W546.1 lm/mF
5000 K136.4 lm/W818.6 lm/mD110.3 lm/W662 lm/mE91 lm/W546 lm/mF
6500 K130.7 lm/W784.4 lm/mE105.9 lm/W635.6 lm/mF87.9 lm/W527.4 lm/mF

Grade KE (3rd Tier)

Grade KE (3rd Tier) — measured at 7.2 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K102.8 lm/W739.9 lm/mF82.2 lm/W592 lm/mG
2300 K114.6 lm/W824.8 lm/mE91.6 lm/W659.9 lm/mF74.2 lm/W534.2 lm/mG
2700 K123.5 lm/W889.1 lm/mE99.4 lm/W715.6 lm/mF80.5 lm/W579.9 lm/mG
3000 K129.6 lm/W933.4 lm/mE105 lm/W756.3 lm/mF85.4 lm/W614.9 lm/mF
3500 K131.6 lm/W947.7 lm/mE107.1 lm/W771.3 lm/mF88.2 lm/W634.9 lm/mF
4000 K135.5 lm/W975.5 lm/mD109.4 lm/W787.7 lm/mF90.3 lm/W649.9 lm/mF
5000 K135.3 lm/W974.1 lm/mD109.4 lm/W787.7 lm/mF90.3 lm/W650.2 lm/mF
6500 K129.6 lm/W933.4 lm/mE105 lm/W756.3 lm/mF87.2 lm/W627.8 lm/mF

Grade KE (3rd Tier)

Grade KE (3rd Tier) — measured at 9.6 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K101 lm/W970 lm/mF80.9 lm/W776.2 lm/mG
2300 K112.6 lm/W1081.4 lm/mE90.1 lm/W865.1 lm/mF73 lm/W700.8 lm/mG
2700 K121.4 lm/W1165.7 lm/mE97.7 lm/W938.1 lm/mF79.2 lm/W760.3 lm/mG
3000 K127.5 lm/W1223.7 lm/mE103.3 lm/W991.5 lm/mF84 lm/W806.1 lm/mG
3500 K129.4 lm/W1242.4 lm/mE105.3 lm/W1011.2 lm/mF86.7 lm/W832.4 lm/mF
4000 K133.2 lm/W1279 lm/mE107.6 lm/W1032.7 lm/mF88.8 lm/W852 lm/mF
5000 K133 lm/W1277.1 lm/mE107.6 lm/W1032.7 lm/mF88.7 lm/W851.5 lm/mF
6500 K127.5 lm/W1223.7 lm/mE103.3 lm/W991.5 lm/mF85.7 lm/W822.7 lm/mF

Grade KE (3rd Tier)

Grade KE (3rd Tier) — measured at 10.8 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K100.2 lm/W1082.1 lm/mF80.2 lm/W865.9 lm/mG
2300 K111.7 lm/W1206.4 lm/mE89.4 lm/W965.1 lm/mF72.4 lm/W781.9 lm/mG
2700 K120.4 lm/W1300.4 lm/mE96.9 lm/W1046.6 lm/mF78.5 lm/W848.1 lm/mG
3000 K126.4 lm/W1365.1 lm/mE102.4 lm/W1106.1 lm/mF83.3 lm/W899.3 lm/mG
3500 K128.3 lm/W1386 lm/mE104.4 lm/W1128 lm/mF86 lm/W928.5 lm/mF
4000 K132.1 lm/W1426.7 lm/mE106.7 lm/W1152.1 lm/mF88 lm/W950.5 lm/mF
5000 K131.9 lm/W1424.7 lm/mE106.7 lm/W1152.1 lm/mF88 lm/W950.4 lm/mF
6500 K126.4 lm/W1365.1 lm/mE102.4 lm/W1106.1 lm/mF85 lm/W918 lm/mF

Grade KE (3rd Tier)

Grade KE (3rd Tier) — measured at 12 W/m: luminous efficacy (lm/W), luminous flux (lm/m) and ErP energy class per CCT and CRI grade.
CCT (K)Ra 80 — Luminous Efficacy (lm/W)Ra 80 — Luminous Flux (lm/m)Ra 80 — ErP Energy ClassRa 90 — Luminous Efficacy (lm/W)Ra 90 — Luminous Flux (lm/m)Ra 90 — ErP Energy ClassFull Spectrum (Ra 95+) — Luminous Efficacy (lm/W)Full Spectrum (Ra 95+) — Luminous Flux (lm/m)Full Spectrum (Ra 95+) — ErP Energy Class
1900 K99.4 lm/W1192.2 lm/mF79.5 lm/W954 lm/mG
2300 K110.8 lm/W1329.2 lm/mE88.6 lm/W1063.3 lm/mF71.8 lm/W861.6 lm/mG
2700 K119.4 lm/W1432.7 lm/mE96.1 lm/W1153.1 lm/mF77.9 lm/W934.4 lm/mG
3000 K125.3 lm/W1504.1 lm/mE101.6 lm/W1218.7 lm/mF82.6 lm/W990.8 lm/mG
3500 K127.3 lm/W1527.1 lm/mE103.6 lm/W1242.8 lm/mF85.3 lm/W1023 lm/mF
4000 K131 lm/W1572 lm/mE105.8 lm/W1269.3 lm/mF87.3 lm/W1047.2 lm/mF
5000 K130.8 lm/W1569.7 lm/mE105.8 lm/W1269.3 lm/mF87.3 lm/W1047.6 lm/mF
6500 K125.3 lm/W1504.1 lm/mE101.6 lm/W1218.7 lm/mF84.3 lm/W1011.6 lm/mG

Related models in this series

See every model in SMD LED Strip Series or narrow to 2835. Compare wattage, lumen output and run length in the ProCalc parameter library, or request OEM/ODM pricing on the custom manufacturing page.

Frequently Asked Questions

What are the key specifications of 2300?

2300: 2835, 60 LEDs/m, DC 12V, 8mm PCB, 3oz copper FPCB, cuttable 3LEDs/50mm. Full photometric data, wiring diagrams and test reports are available in the downloads section of this page.

How long can a single run of this 24V SMD LED strip lights be?

Maximum single run for this model is 5m. Feeding from both ends or using a mid-point tap halves the effective distance per segment, so a 24V SMD LED strip lights can cover twice that length on one circuit when wired accordingly.

Can DENO customise this 24V SMD LED strip lights for a project?

Yes. DENO manufactures the Classic SMD Strips series as an OEM and ODM supplier: reel length, colour temperature, CRI grade, PCB width, waterproofing and private labelling can all be specified. Request a quote for lead time and project pricing.

Which SMD LED strip density should you specify?

For general cove and shelf lighting, 120 LEDs/m on a 24V LED strip is the usual baseline. Move to 180 or 240 LEDs/m when the strip sits close to a diffuser or is seen at a shallow angle, since higher density is what removes visible dots on a 2835 LED strip.

Which LED driver and run length suit #2300?

2835 Classic LED Strip Light | 8mm | 12V | 60LEDs | 50mm/cut | #2300 is a constant-voltage DC 12V product, so pair it with a CE or UL listed DC 12V constant-voltage LED driver rated about 20% above the connected load. Maximum single run is 5m. 5m Single/10m Dual Input power. Feeding from both ends or mid-feeding halves the copper distance and roughly quarters the voltage drop.